Summary of Contents for K22 DPV

Page 1: ...Merope dive tools Compass K22 DPV 1 Manual Compass K22 DPV...

Page 2: ...dive timer 7 2 3 3 GPS menu 7 2 3 4 Screen settings 8 2 3 5 Turn off the compass 9 2 3 6 Standby for dive 10 2 3 7 Calibrate sensors 10 2 3 8 Imperial or metric 12 2 3 9 Reset and update 12 2 3 10 Co...

Page 3: ...e only if you are in good health Merope Engineering is in no way liable for any damage resulting from use of this compass By using this compass you agree with the general terms and conditions of Merop...

Page 4: ...Technical data Operating Temperature Range 2 up to 50 C Storage temperature 5 up to 40 C Compass accuracy 3 degrees resolution 1 degree Maximum depth 100 meter denotation 99 9mtr resolution 10 cm Batt...

Page 5: ...compass will start up and the main screen will appear If no button is pressed the compass will automatically turn off after about 5 seconds The name of the compass owner is also displayed during the...

Page 6: ...A then 1 2 and 3 are shown A Active the selected heading in use 1 2 and 3 show the previously selected headings This table stores multiple heading s selected with the right button In the center of th...

Page 7: ...upload them to the compass Waypoints Above water use the active GPS location as the starting point Then choose the destination from the list of GPS points Underwater choose a previously entered GPS p...

Page 8: ...inate will be saved at the selected position A new coordinate can be saved at any position overwriting the old position GPS status The built in GPS receiver displays the number of satellites received...

Page 9: ...rom the list The active colour is used for all indications except for the the compass rose colours Switch buttons Selecting the menus and confirming them can be reversed using the switch buttons funct...

Page 10: ...nsor This is done on a calibrated horizontal plate and normally does not need to be repeated Calibration by the end user may only be done when a perfectly horizontal plate in x and y direction is avai...

Page 11: ...ce point maintenance applications Set declination Magnetic north and true north geographic poles are not the same The value varies per location and can be positive or negative Also this value varies s...

Page 12: ...values to the factory settings Metric screen orientation screen colour compass barometer calibration brightness 100 declination 0 Update firmware Activate Bluetooth and pair the compass with the K22 D...

Page 13: ...ater type Select here whether it is fresh or salt water 3 Installing the compass on the scooter Mount the compass at a place on the scooter where it is easy to read and operate A good spot is at the t...

Page 14: ...al heading function By using the manual heading function the direction can easily be fixed in the compass rose Do this as follows Point the scooter in the direction of the object you want to navigate...

Page 15: ...e The compass heading remains active under water The distance will only change if a GPS signal is active If there is no GPS signal the distance will remain unchanged The heading dot the heading under...

Page 16: ...8 hours Tapping the housing during charging will bring up the charging screen for a short time Charging the battery only works when the ambient temperature is below 30 C If the battery is will be full...

Page 17: ...K22 DPV 17 Ensure that the Bluetooth module of the computer or laptop is turned on Go to the Bluetooth menu on the computer laptop and select Devices Then choose Bluetooth other devices and click Add...

Page 18: ...ls Compass K22 DPV 18 Click on Bluetooth The computer detects Mantis Click Mantis to add the device Enter the password The password is 0000 and cannot be changed by the user Click Connect to establish...

Page 19: ...s paired The Bluetooth connection is now ready for use Then select More Bluetooth options Then select the COM ports tab to find out the ports connected to the K22 DPV The outgoing communication port i...

Page 20: ...ow the next steps 1 Click on the drop down menu to choose a communication port and select the K22 DPV outgoing communication port In this example COM3 2 Click on Connect to activate the Bluetooth conn...

Page 21: ...2 DPV can be retrieved using the Read button After adjusting the desired settings they can be saved in the compass by using the Write button Here you can enter the text you would like to see on the st...

Page 22: ...mpass and the version that will be uploaded Then click on Start upload The K22 DPV screen will show a countdown of 3 2 1 and then the upload starts The green bar appears and will turn completely green...

Page 23: ...ed Place the compass as close as possible to it In the second case wait 10 minutes before it is possible to restart the K22 DPV on off button If this succeeds start the standard update procedure as di...

Page 24: ...Merope dive tools Compass K22 DPV 24...