background image

.

User Manual

Version: 1.6.0 DR 03 (10.01.2017) - EN

Summary of Contents for mbNET.mini

Page 1: ... User Manual Version 1 6 0 DR 03 10 01 2017 EN ...

Page 2: ...ereby MB CONNECT LINE acknowledges that the device mbNET mini MDH86xx is in complies with the essential requirements and other relevant provisions of directive 1999 5 EC The declaration of conformity can be found at www mbconnectline com Issued by MB Connect Line GmbH Fernwartungssysteme Winnettener Str 6 91550 Dinkelsbühl Germany Tel 49 0 700 622 666 32 49 0 700MBCONNECT Website www mbconnectline...

Page 3: ... 3 mbCONNECT24 Configuration 20 10 1 3 1 Changing your password 20 10 1 3 2 Creating a project 20 10 1 3 3 Create a new device 22 10 1 3 4 Create a configuration 23 10 1 3 4 1 LAN Settings 24 10 1 3 4 2 WiFi Settings 25 10 1 3 4 3 Internet Settings 27 10 1 3 4 4 WAN Settings 29 10 1 3 4 5 Modem Settings 30 10 1 4 Transferring the configuration to the Device 31 10 1 4 1 Download to PC 32 10 1 4 1 1...

Page 4: ... in the Portal V 1 x 57 11 1 System Settings 58 11 1 1 System Settings 58 11 1 2 Time Settings 58 11 1 3 Mail Settings 59 11 2 System WEB 59 11 3 System USB 60 11 4 System Logging 61 11 5 Security Firewall General 62 11 6 Security WAN LAN 63 11 7 Security LAN WAN 64 11 8 Security Forwarding 65 11 9 Security NAT 66 11 10 Alarmmanagement Input 67 11 11 Passwords Password Settings 68 12 Configuring y...

Page 5: ...ia USB 84 14 2 Firmware update via RSP mbCONNECT24 85 15 Technical Data 86 15 1 Technical data MDH 860 86 15 2 Technical data MDH 861 87 15 3 Technical data MDH 862 AT T 88 15 4 Technical data MDH 862 EU 89 15 5 Technical data MDH 863 90 ...

Page 6: ... secure VPN connection to the portal mbCONNECT24 mbCHECK from version V 1 1 2 The program checks that at least one of the 80TCP 443TCP or 1194TCP ports is enabled in the fire wall At least mbDIALUP and a device mbNET mbSPIDER for connection to the platform need one of these ports You will then be notified whether connection via mbDIALUP to the platform is possible The latest version can be downloa...

Page 7: ...al Page 7 of 90 Currently manuals and more information The latest manuals and more information about products related to secure remote maintenance can be found on www mbconnectline com in the download portal ...

Page 8: ...software 3 Legal information Qualified Personnel The product system described in this documentation may be operated only by personnel qualified for the spe cific task in accordance with the relevant documentation in particular its warning notices and safety instruc tions Qualified personnel are those who based on their training and experience are capable of identifying risks and avoiding potential...

Page 9: ... html shortened URL http bit ly 1QXbuuZ Physically access Restrict physical access to safety relevant components to qualified personnel Security functions of the software Keep the software firmware up to date Inform yourself periodically about security updates of the product Information please visit www m bconnectline com Inform yourself periodically about product updates Information please visit ...

Page 10: ...ter can be configured via the portal mbCONNECT24 mymbCONNECT24 mini midi maxi hosted virtual Performance characteristics The router can be fully configured via the portal mbCONNECT24 mymbCONNECT24 mini midi maxi hosted virtual Can connect to machines and systems via LAN WAN WiFi or modem Deployable worldwide using mobile communications plus access via LAN and Internet Secure connection using an in...

Page 11: ... 862 MDH 863 Quick Start Guide GSM antenna Quick Start Guide Should any of these parts are missing or damaged please contact the following address MB CONNECT LINE GMBH Winnettener Str 6 D 91550 Dinkelsbühl Tel 49 0 9851 282529 0 Fax 49 0 9851 282529 99 Please keep the original box and the original packaging in case you need to send the device for repair at a later date ...

Page 12: ...rocess approx 90 sec Rdy Ready LED on The device is ready for operation This LED shows whether the device is connected to the Internet and the portal server LED off No connection to Internet or portal LED flashing 3Hz Internet or VPN connection being established LED flashing 1 5Hz Connection to portal server has been established Con Connect LED on Connection to the Internet has been established LE...

Page 13: ...ting firmware or configuration from USB stick 3 Loading factory settings Reset Pushing this button restarts the device so called cold start View of bottom of device 0 V DC connection Power source connection 10 30 V DC FE Functional earth I 1 Digital input I1 10 30 V DC I 2 Digital input I2 10 30 V DC Input 1 can only be configured for establishing the connection to the portal mbCONNECT24 Input 2 c...

Page 14: ...put I1 10 30V DC I2 Digital input I2 10 30V DC Input 1 can only be configured for establishing the connection to the portal mbCONNECT24 Input 2 can be cofigured to send emails SMS Internet SMS or to start a reboot 8 2 Pinout of LAN WAN ports on the front panel of the device Signal 1 TX 2 TX 3 RX 4 Not connected 5 Not connected 6 RX 8 3 Pinout of the USB port on the front panel of the device Signal...

Page 15: ...nnect the mbNET mini to the power supply ADVICE Before connecting the device to a network or PC first ensure that it is properly connected to a power supply otherwise it may cause damage to other equipment You should therefore follow the instructions given below Connect equipotential bonding to the functional earth FE Connect the mbNET mini to a power supply 10 30 VDC Make sure the polarity is cor...

Page 16: ...ocedure applies Add the mbNET mini in the portal as a new device Enter the necessary basic data so that the device can connect to the portal for example device name network settings connection information etc Transfer the device configuration from the portal into the mbNET mini Alternatively you can enter the necessary connection basic data direct on the web interface of the de vice see chapter In...

Page 17: ...st your access to mbCO NENCT24 and how you connect to the portal Here you can see how to create a device and perform the initial config uration for your mbNET mini In this section you will learn the dif ferent methods how to transfer the initial configuration to the mb NET mini In the last section we show you how to connect to devices and machines and how you finish your mbCON NECT24 session tidy ...

Page 18: ...ine zweite E Mail mit Ihrem Passwort Software download To establish a secure VPN connection to the portal mbCONNECT24you require the remote client software mbDIALUP In our download portal downloads mbconnectline com you can mbDIALUP download in the current version for free Run after extracting the ZIP file the program setupmbdialup exe ADVICE During the installation process you must ensure that yo...

Page 19: ...nada ADVICE The server location can be seen in the confirmation email for subscibing to mbCONNECT24 Access via the proxy server If the Internet can only be accessed via a proxy serv er the relevant settings can be applied in the menu Settings submenu Port Proxy settings Login mbCONNECT24 You can now log in to the portal with the user data username password that were sent to you when you registered...

Page 20: ...hould definitely be completed Unless you change your password this prompt is displayed at each call of home page Click on Change Password Notice that your password has to fit the password guideline Your password is active when you reconnect to the portal 10 1 3 2 Creating a project A project is the highest entity to implement the following tasks remote maintenance monitoring and alarming data logg...

Page 21: ...Description and Access are necessary for the extended configuration Term Description Number Optional field Input value alphanumeric Name Mandatory field Input value alphanumeric Description Optional field Input value alphanumeric The short description entered is dis played in the project overview Cancel By clicking on Cancel the process is terminated All entries settings also in the other tabs Des...

Page 22: ... field to enter a unique device name You can create your own name for your Device Following numbers and letters are allowed 0 to 9 A to Z a to z avoid blanks Description Optional fieldto enter a briefdescription for the device The description can be freely selected and will be displayed later in the device overview All numbers words blank spaces or additional characters are allowed Serial number a...

Page 23: ...a Device the ac tual configuration menu appears For the basic configuration are solely the following Interfaces necessary LAN WiFi Internet WAN Modem ADVICE According to the Type of your Device the list of the interfaces could variegate Click the edit icon to make the settings on the submenus ...

Page 24: ...should use a different address range LAN Settings IP Enter the IP address of your Device Netmask Enter the Subnetmask where your Device should be integrated 1 1NAT Network Activate 1 1NAT Network if both contacts use the same Net address and want to communicate with each other virtual Network 1 1NAT Enter your address of your network e g 192 168 100 0 24 Make sure you use the CIDR spelling for the...

Page 25: ...ection field for the authentication mode Encryption Mode Selection field for the encryption mode Encryption Key Mandatory field Enter the encryption key Encryption Key confirmation Mandatory field Enter the encryption key again Channel Selection field for the WiFi channel WAN Settings WAN Type DHCP Select this entry if you have a DHCP server in your network WAN Einstellungen WAN Typ DHCP WAN Type ...

Page 26: ...gs WAN Type Static IP WAN Type Selection field for the WAN type DHCP or Static IP WAN IP Mandatory field Enter the IP Address of the external Router WAN Netmask Mandatory field Enter the Subnet mask where your Device should be integrated Gateway Mandatory field Enter the Gateway of the external Router ...

Page 27: ...n on your Device it gets a connection to the Portal Always If the Device is powered on and operational it will connect to the portal SMS If you want to connect the Device with the portal you have to send an SMS with the order to start a VPN connection Input 1 Depending on the device type the connection can be controlled by one or more digital inputs Disconnect after inactivity time Checkbox for ac...

Page 28: ...imarily via the WAN interface If the connec tion can not be established or is interrupted the device switches to connect using the internal modem Failover WAN WiFi Depending on the device and device type the connection takes place primarily via the WAN interface If the connec tion can not be established or is interrupted the device switches to connect using an Access Point WiFi Test connection If ...

Page 29: ...e subnet mask of the corresponding network in which the device is to be inte grated Gateway Enter the respective gateway that connects you to the Internet so the IP address of the existing device DNS Server Select the DNS server that was assigned to you by your Internet service provider ISP or enter your own DNS server Type DHCP Select this if a DHCP server exists in the network and is assigned to...

Page 30: ...r If necessary enter your Username Password If necessary enter your Password Password Confirmation Confirm the password SIM Pin If necessary enter your SIM Pin Enable Service Control via SMS If this checkbox is hooked you can send an SMS to the device for eg restart input query etc Send Email After connection established Activate the checkbox and enter a valid e mail address if you want to be noti...

Page 31: ...has no connection to the portal Prepare for Synchronization You deposit the configuration in the portal for collection by the device Once the device to connect to the portal the configura tion is automatically transferred to the device Prerequisite conditions The Device has a connection to the portal a valid server address is entered in the device Submit to Device Here you transfer the configurati...

Page 32: ...e will recognize the configuration file and indicate this by the slowly flash ing LED Usr flashing frequency 1 5 Hz As soon as the LED Usr starts to flash you must press the Function button within 10 seconds Hold down until the LED Usr lights up Now release the Function button When the LED Usr goes off and the LED Pwr Rdy light up then the configuration transfer is complete When the mbNET mini can...

Page 33: ... connection to the Internet WAN WiFi Modem The device has been pre configured with the connection data Initial configuration using the device surface a valid server address is registered in the device Click on the icon to select the transfer type and then click Prepare for Synchronization No further settings are necessary for the basic configuration Click on Synchronize Once the mbNET mini has log...

Page 34: ...e configuration file to the identified device is correct click on go to confirm In the next window click on start configuration transfer The settings from mbCONNECT24 are now copied to the device If all items have been processed acknowledge the transfer by clicking the Finished button If the mbNET mini is able to connect to the Internet e g network telephone cable SIM card antennae in stalled the ...

Page 35: ...anges the color from green to orange The Connection Icon also changes its color from black to orange and rotates around its axis Your connection to the machine is ready If you want to disconnect you have to click the rotating Connection Icon 10 1 6 Quit the mbCONNECT24 session If you want to sign out your mbCON NECT24 session properly click on the but ton LOGOUT If you click on the button EXIT you...

Page 36: ...les you to establish a secure VPN connection to the mbCON NECT24 portal server Alternatively you can connect via a web browser over a secure https VPN connection to the Portal Server Type and serial number of your mbNET mini ADVICE For more information about mbCONNECT24 V 1 x see mbconnectline com Login mbCONNECT24 Establish via mbDIALUP or https eg Https vpn2 mbconnect24 net a connection to the p...

Page 37: ...u log in to the portal 10 2 1 Adding a new device mbCONNECT24 V 1 x ADVICE Here the necessary basic settings for a minimal configuration will be described so that the device can connect to the portal For more information see the Portal online help Go to the Machines Devices menu and assign a unique designation under Name ADVICE You can choose any designation although only the following numbers and...

Page 38: ...contact details here e g a contact person in the device s location Password The VPN password is generated automatically Please note that this password is used for authenticat ing the device Each device absolutely must be given an individual password Serial number The device s serial number can be entered here How ever as soon as the device connects to the portal for the first time it is automatica...

Page 39: ... communi cation through both networks ADVICE Make sure that the LAN IP and WAN IP are in different address ranges WiFi Settings MDH 863 SSID Enter the name of the wireless net work to wich the device should con nect Authentication Mode Select the authetification methode Encryption Mode Select the encryption methode Encryption Key Enter the Encryption Key Encryption Key confir mation Repead the ent...

Page 40: ... for static IP Select this setting if connection to the Internet is already established via an existing router that is not acting as a DHCP sever or if no server is set up to assign addresses You should also select this setting if you have received a static address from your ISP e g if you have a leased line A DNS server address must however still be entered Which VPN port should be used which of ...

Page 41: ...der Own entry enter login information You can obtain information on the APN from your mobile broadband provider If required you can enter the SIM card PIN of the SIM card used here Select which VPN port should be used which of the three ports is free was determined by mbCHECK After saving your settings you will see the new device in the Device Administration window Click on the disk icon of that d...

Page 42: ... static IP Select this setting if connection to the Internet is already established via an existing router that is not acting as a DHCP sever or if no server is set up to assign addresses You should also select this setting if you have received a static address from your ISP e g if you have a leased line A DNS server address must however still be entered Which VPN port should be used which of the ...

Page 43: ...erring the configuration to mbNET mini The following options are available for transferring the configuration file Download to PC Prepare for CTM Submit to Device Once you have created a new device click on the disk symbol to select the transfer type ...

Page 44: ... slowly flashing LED Usr flashing frequency 1 5 Hz As soon as the LED Usr starts to flash you must press the Function button within 10 seconds Hold down until the LED Usr lights up Now release the Function button When the LED Usr goes off and the LED Pwr Rdy light up then the configuration transfer is complete When the mbNET mini can connect to the In ternet e g network cable SIM card antennae ins...

Page 45: ...er when creating a device the device serial number must be entered Click on the disk icon in the Device Administra tion and then on Prepare for CTM In the next window select whether a notification email should be sent and to which address as soon as the device has collected the configuration After confirming via the interface Prepare for CTM a symbol shows that the configuration is ready to be col...

Page 46: ...ortal After clicking Submit configuration to de vice the system performs a scan of all de vices connected to the LAN interface mb NET mbSPIDER and displays them If the assignment of the configuration file to the identified device is correct click on go to confirm In the next window click on start configu ration transfer The settings from mbCONNECT24 are now copied to the device If all items have b...

Page 47: ...P Your computer s IP address must be in the ad dress range 192 168 0 X the subnet mask must be identical to that of the mbNET mini 255 255 255 0 You must enter the IP address of the mbNET mini 192 168 0 253 as the default gateway and as the pre ferred DNS server Default settings for mbNET mini IP address 192 168 0 100 Subnet mask 255 255 255 0 Login admin Password no password required ADVICE Chang...

Page 48: ...his value can not be changed External router when using WAN and WLAN devices MDH 860 MDH 863 Modem when using modem devices MDH 861 MDH 862 To continue click on Next WAN Settings MDH 860 In the selection box WAN Type you have the follow ing options DHCP Static IP When using a proxy server select the check box Use Proxy To continue click on Next ...

Page 49: ...ider and the SIM PIN here That is possible in Network Provider a list of providers If your provider can not be found in the list you can fill in each field individually To continue click on Next WLAN Settings Connection to the Internet MDH 863 In the selection box WLAN Type you have the follow ing options DHCP Static IP To continue click on Next ...

Page 50: ... Enter the name of the WiFi network to which the device should connect Authetification Mode Selection field for the authentication mode Encrypt Mode Selection field for the encryption mode Key Mandatory field Enter the encryption key again Use Proxy When using a proxy server select the check box Use Proxy To continue click on Next Proxy Enter the information for your proxy To continue click on Nex...

Page 51: ...mbconnect24 net US CAN rsp vpn mbconnect24 us RSP mbCONNECT24 V 2 x User Defined Cloud server address name URL mymbCONENCT24 Server V 1 x 2 x mymbCONNECT mini midi maxi hosted virtual Session Key As an additional safety feature can be generated in the portal a session key With this key the device reads from his portal configuration If a session key is generated it must be entered here Each key is ...

Page 52: ...download the device download now its configura tion In the header of the Status page see the following fields buttons Language Selection field for the user language Setup Calling the setup menu Firststart Help Calling the device online help Reboot Triggering a device restart In the device status bar following information is displayed all device types Device type and Firmware version Serial number ...

Page 53: ...nternet SMS has been configured the button Test appears Clicking this button will carry out a test on the setting Additional information can be obtained by clicking on the Logging or the Diagnostic link These data help us to provide additional support when dealing with problems MDH 860 MDH 861 MDH 862 MDH 863 all device types Connecting to the Internet Here the connection is requested to the Inter...

Page 54: ...ded to establish the connection to the portal Additional information can be obtained by clicking on the Logging link These data help us to provide additional support when dealing with problems all device types Connecting to the Portal Server Here the connection status to the Portal Server is request ed and displayed Additional information can be obtained by clicking on the Logging link These data ...

Page 55: ...te of the last update of the configuration By clicking the button CTM restart another request will start to look for a recent configuration Additional information can be obtained by clicking on the Logging link These data help us to provide additional support when dealing with problems The User who currently has an active VPN connection to this device If there is no active connection this is indic...

Page 56: ...e TraceRoute Here it is possible to enter an internet page or an IP address When actuat ing the TraceRoute button the routing command is executed This command starts a route tracing and visualizes it This allows you to get much more infor mation on a network connection NS Lookup Check the function of the nameserver with the button NS Lookup There s no matter what kind of internet connection you ha...

Page 57: ...ver mbCONNECT24 1 Therefor after logon at the Portal go to the menu Machines Devices 2 Select that particular device for configuration via the edit button 3 Change if necessary to the Settings tab ADVICE All settings and changes are only effective after they have been transferred as a configuration on the device see chapter Transferring the configuration to mbNET mini ...

Page 58: ...en checked the device time will be synchronized automatically via the set NTP server preset address 0 de pool ntp org A time server IP address may be entered instead of a name If a name is entered there must be a DNS server entered in the net work settings or an existing Internet connection The NTP server simply needs to be available The time is only automatically synchronized when NTP Server Enab...

Page 59: ...SMTP Username SMTP Password A user name and password is required for SMTP server authentication i e if the router wants to send an email to the SMTP it may have to first authentificate itself 11 2 System WEB Enter the port here and select the type of connection that will enable you to access the Web GUI of the mbNET mini HTTP Port The standard port for HTTP requests is TCP 80 You can however selec...

Page 60: ...90 Version 1 6 0 DR 03 10 01 2017 EN 10 01 2017 11 3 System USB USB Access from Network When Active is checked the USB memory can be accessed via an SFTP client Default settings SFTP Username ftp SFTP Password ftp ...

Page 61: ...ccessed on the USB stick which is connected to the mbNET mini file name of the logging file Device name log Remote Logging Enable Remote logging if this checkbox is activated the mbNET mini system logging can be outsourced to another computer Remote IP Address enter here the IP address of the external logging server Remote Port port 514 is preset here We recommend that you do not change this port ...

Page 62: ...rom the VPN tunnel Normal Security With this setting incoming data traffic data from the Internet is denied while outgoing data traffic is al lowed Minimum Security With this setting all incoming and outgoing data traffic is allowed ADVICE The minimum Security option should only be temporarily set for test purposes since it allows all data traffic from inside to outside the network as well as acce...

Page 63: ...are delet ed immediately The sender is not notified about the whereabouts of the data packets Reject If this option is selected the data packets are rejected The sender is notified that the da ta packets have been rejected Accept If this option is selected the data packets can pass WAN interface This defines the WAN interface to which the setting is to be applied Internet or WAN Ether net can be s...

Page 64: ...cted the data packets can pass Source IP Enter the IP of a computer from which data packets are sent to the Internet here If you leave the field blank the set action applies to all IP addresses Source Port Enter the port via which the data packets are sent into the Internet here Protocol The following options are available for selection All This setting applies to all protocols TCP This setting on...

Page 65: ...s to the TCP protocol UDP This setting only applies to the UDP protocol ICMP This setting only applies to the ICMP protocol Destination IP Enter the IP to which the data packets were originally to be sent here Destination Port Specify the port via which the data packets are sent to the destination IP here Forward IP Enter the IP to which the data packets are actually to be forwarded here Forward P...

Page 66: ...en these two networks This means that you do not have to adapt your entire network addressing scheme Bezeichnung Beschreibung Enable If the box has been checked the following settings will be active after saving Netaddress LAN Enter the real address of the network here e g 192 168 0 0 24 ADVICE Please note that the IP address must be entered in CIDR notation Netaddress NAT Enter the translated add...

Page 67: ...on under Step 1 The state of Input 2 s signal is shown with the prepended soft LED grey 0 low green 1 high If an email text message or Internet text message has been configured the button Test email appears Clicking this button will carry out a test on the setting Input 1 can only be configured for establishing the connec tion see Machines Device Administration Internet Once it has been configured...

Page 68: ...s and password preset WEB GUI Username admin WEB GUI Password kein Passwort notwendig ADVICE Change the device password to prevent unauthorized access to the device ADVICE These and all changes that you make for the mbNET mini in the portal will only take effect when the set tings changes made are transferred to the device as a configuration ...

Page 69: ... SMTP server Firewall here you can specify the global settings for Fire wall security Firewall Security Levels and create Firewall rules Alarmmanagement here you can configure the digital in put 2 of the mbNET mini VPN here you can choose a VPN port and if necessary a VPN gateway User Administration here you change the password for accessing the device GUI NTP Server here you specify the NTP serve...

Page 70: ... time the device is to perform a re boot automatically The currently installed firmware version with a note of its actuality ADVICE The orange LED is displayed when a newer firmware version is available By clicking on the LED symbol an automatic firmware update is performed To change the settings click on the Edit button System Reboot after h Enter a period of time in hours after which the de vice...

Page 71: ...ce to be able to send e mails you can obtain more detailed information on this from your service provider SMTP Port Enter the port used to send e mails usually port 25 E Mail Address Enter the e mail address to serve as the send ing address SMTP requires Au thentification Checkbox for whether the selected SMTP serv er requires authentication SMTP Username Enter the username required for authentica...

Page 72: ... from the LAN are ac cepted Minimum security All incoming packages data from the Internet are accepted All outgoing packages data from the LAN are ac cepted ADVICE ATTENTION The Minimum security option should only be set temporarily for test purposes since it allows all data traffic from inside to outside the network as well as access from outside the network This setting puts the integrity of you...

Page 73: ...w Select from the drop down menu one of the topics Enter the necessary data and Save your settings The new rule will then appear in the overview of the firewall settings To edit a firewall rule click the edit icon To delete a firewall rule click on the minus icon ADVICE Changes in the portal which concern the device will take effect after the Portal configuration has been transferred to the device...

Page 74: ...he query state 0 or 1 in which an action to be performed Action Choose an action from the dropdown list Send E Mail System Reboot SMS or Internet SMS Text Here enter a message text E Mail When action choosing Send E Mail enter here the recipient email address SMS When action choosing SMS enter here the re cipient phone number Internet SMS When action choosing Internet SMS enter here the recipient ...

Page 75: ...sary a VPN gateway To change the settings click on the Edit button VPN Port Here you can select a vacant VPN port but make sure that this port is enabled in the fire wall Gateway Here select a VPN Gateway ADVICE Changes in the portal which concern the device will take effect after the Portal configuration has been transferred to the device If the device configuration is out of date this is indicat...

Page 76: ...Define rules for the use of equipment and assigning passwords Regularly change the passwords to increase security Always use passwords with high strength password Avoid weak passwords such B password1 123456789 or the like Make sure that all passwords are protected and inaccessible to unauthorized personnel Never use one password for different users and systems ADVICE Changes in the portal which c...

Page 77: ...he Edit button NTP Server active Checkbox for activating deactivating the NTP function NTP Server Enter the NTP server here preset address 0 de pool ntp org You can enter a time server IP address instead of a name If you enter a name there must be a DNS server entered in the network settings or an existing Internet connection The NTP server simply needs to be available NTP Interval h Enter the val...

Page 78: ... the settings click on the Edit button Standard date time YYYY MM DD HH M M SS Input of the date time in the UTC format YYYY MM DD HH MM SS 2015 03 06 19 23 48 Timezone Selection field for the time zone in which the device is located ADVICE Changes in the portal which concern the device will take effect after the Portal configuration has been transferred to the device If the device configuration i...

Page 79: ...hange the default port To change the settings click on the Edit button Protocol Selection field for the connection type with which you wish to access the web server HTTP with preset standard port 80 HTTPS with preset standard port 443 Port If necessary the standard port can be changed here ADVICE Changes in the portal which concern the device will take effect after the Portal configuration has bee...

Page 80: ...f the device Automatic login Checkbox for activating deactivating the auto matic login to the web interface of the device Username Enter the username for authentication on the device Password Enter the corresponding password Password Confir mation Repeat the password If all the parameters have been entered correctly this will take you to the web interface of the device directly and without polling...

Page 81: ...is connected to the device file name of the logging file Device name log Activate External Logging Server Checkbox for activating deactivating the additional output of the system logging Using an external logging server the device system logging can be can be outsourced to another computer Remote IPAddress Enter the IP address of the external logging server here Remote Port Enter the port of the e...

Page 82: ... to adjust the network settings of the configuration computer accordingly To reset the mbNET mini to factory settings proceed as follows Click the button Reset once Then press Function straight afterwards and keep it pressed down After about 60 90 seconds the Rdy LED starts flashing As soon as the Usr LED starts to flash re lease the button Function When the LED Pwr and Rdy light up the factory se...

Page 83: ...face of the device The latest firmware version can be found in the download area on www mbconnectline com If you operate your mbNET mini in association with the RSP mbCONNECT24 version 2 x you can perform the firmware update via the portal For this you will be provided the latest firmware version by the portal ...

Page 84: ...king LED Usr flashing frequency 3 Hz Now press within 10 seconds the button Function and keep it pressed until the Usr LED lights When Usr LED lights release the button Function The device afterwards is going to restart When the two LED Pwr and Rdy light up the firmware update is finished The mbNET mini is now ready for operation again and can as usual be used ADVICE If there is both a firmware fi...

Page 85: ...f the rele vant device If a newer firmware exists than the one you are using this is displayed on Services System Settings by an orange LED with an exclamation mark To start the firmware update click the LED and accept the prompt After performing the update the mes sage appears Upgrade Finished The new firmware will not take effect until after a device reboot Click the arrow icon to restart the de...

Page 86: ...ange HW1 0 50 C 20 75 C Storage temperature range Storage temperature range HW1 20 60 C 40 90 C Humidity 0 95 non condensing Weight 230 g Dimensions 69 mm x 25 mm x 85 mm W x D x H LAN interface x 3 10 100MBit s full and half duplex mode automatic recognition patch cable crossover cable WAN interface 10 100MBit s full and half duplex mode automatic recognition patch cable crossover cable Inputs x ...

Page 87: ...rage temperature range HW1 20 60 C 40 90 C Humidity 0 95 non condensing Weight 240 g Dimensions 69 mm x 30 mm x 85 mm W x D x H GPRS category 12 max 86 5kBit s EDGE category 12 max 236 8kBit s HSxPA category Downlink HSDPA Category 14 21 Mbps Uplink HSUPA Category 6 5 76 Mbps Supported frequency bands 800 850 900 AWS 1700 1900 2100 MHz LAN interface x 4 10 100MBit s full and half duplex mode autom...

Page 88: ...erature range Storage temperature range HW1 20 60 C 40 90 C Humidity 0 95 non condensing Weight 240 g Dimensions 69 mm x 30 mm x 85 mm W x D x H Supported frequency bands 2G Bands 3G Bands LTE Bands GSM 850 PCS 1900 B17 700 B5 850 B4 1700 B2 1900 B5 850 B2 1900 B17 700 B5 850 B4 1700 B2 1900 LAN interface x 4 10 100MBit s full and half duplex mode automatic recognition patch cable crossover cable ...

Page 89: ...ge temperature range Storage temperature range HW1 20 60 C 40 90 C Humidity 0 95 non condensing Weight 240 g Dimensions 69 mm x 30 mm x 85 mm W x D x H Supported frequency bands 2G Bands 3G Bands LTE Bands GSM 900 DCS 1800 B5 850 B8 900 B1 2100 B20 800 B3 1800 B7 2600 LAN interface x 4 10 100MBit s full and half duplex mode automatic recognition patch cable crossover cable Inputs x 2 Low 0 3 2 V h...

Page 90: ...5 mm Wx D x H WiFi IEEE802 11b g 802 11n 1T1R mode up to 150 MBit s WiFi specifications EU 2 412 GHz 2 472 GHz 1 13 Channel USA 2 412 GHz 2 462 GHz 1 11 Channel WPA WP2 64 128 152 bit WEP WPS 802 11b 1 2 5 5 11 Mbps 802 11g 6 9 12 18 24 36 48 54 Mbps 802 11n 20 Mhz MCS0 7 up to 72 Mbps 802 11n 40 Mhz MCS0 7 up to 150 Mbps LAN interface x 4 10 100 MBit s full and half duplex mode automatic recognit...