ATTENTION INSTALLING PERSONNEL

As a professional installer, you have an obligation to know 

the product better than the customer. This includes all safety 

precautions and related items.
Prior to actual installation, thoroughly familiarize yourself 

with this Instruction Manual. Pay special attention to all 

safety warnings. Often during installation or repair, it is 

possible to place yourself in a position which is more 

hazardous than when the unit is in operation.
Remember, it is 

your

 responsibility to install the product 

safely and to know it well enough to be able to instruct a 

customer in its safe use.
Safety is a matter of common sense...a matter of thinking 

before acting. Most dealers have a list of specific, good 

safety practices...follow them.
The precautions listed in this Installation Manual are 

intended as supplemental to existing practices. However, 

if there is a direct conflict between existing practices and 

the content of this manual, the precautions listed here take 

precedence.

Installer:  Affix all manuals 

adjacent to the unit.

These furnaces comply with requirements embodied in the 

American National Standard/National Standard of Canada 

ANSI Z21.47·CSA-2.3 Gas Fired Central Furnaces.

IOG-2031

09/2021

Installation Instructions for

*M9S80*U Ultra Low NOx Gas Furnace 

 

CATEGORY I  CATÉGORIE I

TABLE OF CONTENTS

SAFETY  CONSIDERATIONS ....................................................... 3

 

Shipping Inspection ...........................................................

5

 

Electrostatic Discharge (ESD) Precautions .........................

5

 

To The Installer ..................................................................

6

PRODUCT APPLICATION ...........................................................

6

LOCATION REQUIREMENTS AND CONSIDERATIONS ................ 7

 

Clearances and Accessibility..............................................

8

 

Installation Positions .........................................................

8

 

Horizontal Installation .......................................................

8

 

Furnace Suspension .......................................................... 9

 

Existing Furnace Removal .................................................. 9

 

Thermostat Location ......................................................... 9

COMBUSTION AND VENTILATION AIR REQUIREMENTS ........ 10

CATEGORY I VENTING (VERTICAL VENTING) .......................... 10

MASONRY CHIMNEYS ............................................................ 11

 

Masonry Chimney Termination ....................................... 11

ELECTRICAL CONNECTIONS ................................................... 11

 

Wiring Harness ................................................................ 11

 

120 Volt Line Connections ............................................... 11

 

Junction Box Relocation .................................................. 11

 

24 Volt Thermostat Wiring .............................................. 12

 

120 Volt Line Connection of Accessories ........................ 12

 

Humidifier and Electronic Air Cleaner ............................. 12

 

Fossil Fuel Applications ................................................... 13

GAS SUPPLY AND PIPING ....................................................... 13

 

High Altitude Derate ....................................................... 13

 

Gas Piping Connections ................................................... 13

 

Upflow Installations ........................................................ 14

 

Gas Piping Checks  ........................................................... 14

CIRCULATING AIR AND FILTERS  ............................................. 15

R

ECOGNIZE THIS SYMBOL

AS A SAFETY PRECAUTION 

NOTE

: Please contact your distributor or our website listed below 

for the applicable Specification Sheet referred to in this manual. 

Only personnel that have been trained to install, adjust, service 

or repair (hereinafter, “service”) the equipment specified in 

this manual should service the equipment. The manufacturer 

will not be responsible for any injury or property damage 

arising from improper service or service procedures.  If you 

service this unit, you assume responsibility for any injury or 

property damage which may result.  In addition, in jurisdictions 

that require one or more licenses to service the equipment 

specified in this manual, only licensed personnel should service 

the equipment.  Improper installation, adjustment, servicing or 

repair of the equipment specified in this manual, or attempting 

to install, adjust, service or repair the equipment specified in 

this manual without proper training may result in product 

damage, property damage, personal injury or death.

19001 Kermier Rd. Waller, Tx 77484

www.goodmanmfg.com • www.amana-hac.com

© 2021 Goodman Manufacturing Company, L.P. 

 is a registered trademark of Maytag Corporation or its related companies and is  

used under license. All rights reserved.

WARNING

DO NOT BYPASS SAFETY DEVICES

Summary of Contents for Amana M9S80-U Series

Page 1: ...stat Location 9 COMBUSTION AND VENTILATION AIR REQUIREMENTS 10 CATEGORY I VENTING VERTICAL VENTING 10 MASONRY CHIMNEYS 11 Masonry Chimney Termination 11 ELECTRICAL CONNECTIONS 11 Wiring Harness 11 120...

Page 2: ...peed Selection 22 Heat Pump Heating Mode Speed Slection 22 Circulator Blower Fan Timing Adjustment 23 On Off Fan Delay Selection 23 OPERATIONAL CHECKS 23 Checking Duct Static 23 SAFETY CIRCUIT DESCRIP...

Page 3: ...ce qui peut entra ner la mort des blessures ou des dommages mat riels IF THE INFORMATION IN THESE INSTRUCTIONS IS NOT FOLLOWED EXACTLY A FIRE OR EXPLOSION MAY RESULT CAUSING PROPERTY DAMAGE PERSONAL I...

Page 4: ...nt pas suivies pour chacun des appareils raccord s au syst me de ventilation au moment de sa mise en marche cela peut entra ner une intoxication au monoxyde de carbone ou la mort Les tapes suivantes d...

Page 5: ...ing precautions during furnace installation and servicing to protect the integrated control module from damage By putting the furnace the control and the person at the same electrostatic potential the...

Page 6: ...furnace A return air temperature range between 60 F 16 C and 80 F 27 C is maintained Air filters are installed in the system and replaced daily during construction and upon completion of construction...

Page 7: ...icals halogen type refrigerants printing inks cleaning solutions such as perchloroethylene paint removers varnishes hydrochloric acid cements and glues antistatic fabric softeners for clothes dryers m...

Page 8: ...gas electrical and drain line connections NOTE In addition to the required clearances to combustible materials a minimum of 24 service clearance must be available in front of the unit Installation Po...

Page 9: ...ndition c In so far as practical close all building doors and windows and all doors between the space in which the appliance s connected to the venting system are located and other spaces of the build...

Page 10: ...oset or utility room must have two ventilation openings with a total minimum free area of 0 25 square inches per 1 000 BTU hr of furnace input rating Refer to Specification Sheet applicable to your mo...

Page 11: ...ation purposes Refer to the wiring diagram for wire routings If any of the original wire as supplied with the furnace must be replaced it must be replaced with wiring material having a temperature rat...

Page 12: ...NG OR CHANGING ANY ELECTRICAL WIRING WARNING 4 Attach the junction box to the left side of the fur nace using the screws removed in step 2 5 Check the location of the wiring Confirm that it will not b...

Page 13: ...e is equipped with de di cated inch EAC and HUM relay terminals for controlling external power to an optional field supplied humidifier and or electronic air cleaner Additional line voltage wiring to...

Page 14: ...90 170 350 530 90 40 84 160 320 490 100 38 79 150 305 460 Pressure 0 5 psig or less and pressure drop of 0 3 W C Based on 0 60 Specific Gravity Gas CFH BTUH Furnace Input Heating Value of Gas BTU Cubi...

Page 15: ...he furnace should be installed in parallel with or on the upstream side of the cooling unit to avoid condensa tion in the heating element With a parallel flow arrange ment the dampers or other means u...

Page 16: ...thermostat contacts close initiating a call for heat The control will display heat mode in status menu g h Integrated control module performs safety circuit checks Induced draft blower is energized fo...

Page 17: ...od The electronic air cleaner EAC and humidifier HUM relays will close the contacts After the thermostat is satisfied the compressor is de energized and the electronic air cleaner EAC and humidifier H...

Page 18: ...The control is now ready to receive demands from the room thermostat Refer to Status Menu in this manual for interpretation of items displayed in the status menu Quick Start Initial set up of outdoor...

Page 19: ...irculation blower will shut down when the time delay expires Time delay is selectable on all models 2 Turn off the electrical power supply to the furnace 3 Remove the burner compartment door 4 White R...

Page 20: ...re gauge at the gas valve outlet pressure tap See White Rodgers 36J22Y 204 gas valve Figure 13 for location of outlet pressure tap 5 Turn ON the gas supply 6 Turn ON power and close thermostat R and W...

Page 21: ...the supply air temperature to determine the air temperature rise Allow adequate time for thermometer readings to stabilize 4 Adjust temperature rise by adjusting the circulator blower speed Increase...

Page 22: ...Cooling Speed Table Gas Heating Mode Speed Selection To change the main blower speed in GAS HEATING mode see the following steps 1 Press menu button until LED displays gAF Press option button and LED...

Page 23: ...ic refers to everything external to the furnace cabinet Cooling coils filters ducts grilles registers must all be considered when reading your total external static pressure The supply duct pressure m...

Page 24: ...horizontal right and horizontal left installations Regardless of airflow direction it does not need to be relocated Burner Temperature Switch The burner temperature switch is mounted on the burner ass...

Page 25: ...lubricated by the manufacturer No further lubrication is required Check motor windings for accumulation of dust which may cause overheating Clean as necessary Flame Sensor Qualified Servicer Only Und...

Page 26: ...ailable from your distributor Functional Parts List Gas Valve Natural Gas Orifice Burner Assembly Hot Surface Igniter Flame Sensor Gas Manifold Ignition Control Blower Mounting Bracket Pressure Sensor...

Page 27: ...ntegrated Control Module 10 Transformer 11 Blower Door Interlock Switch 12 Circulator Blower Tubular Heat Exchanger Pressure Sensor Assembly Flue Pipe Connection Gas Line Entrance Gas Valve Inducer Ga...

Page 28: ...o call for heat Correct short at flame sensor or in flame sensor wiring Short to ground in flame sense circuit Lingering burner flame Slow closing gas valve Open fuse Replace fuse Short in low voltage...

Page 29: ...sor and pressure switch Check Red Black Green harness connections to pressure sensor control board Replace pressure sensor Check Red Black Green harness connections to pressure sensor control board Re...

Page 30: ...72 1353 1325 1291 1255 1219 SP6 1528 1485 1438 1409 1383 1349 1317 1285 SP7 1619 1579 1551 1523 1495 1463 1430 1402 SP8 1746 1697 1667 1642 1617 1593 1570 1540 SP9 1772 1735 1698 1674 1645 1622 1598 1...

Page 31: ...1485 30 1438 31 1409 32 1383 32 1349 1317 1285 SP7 1619 27 1579 28 1551 29 1523 29 1495 30 1463 1430 1402 SP8 1746 25 1697 26 1667 27 1642 27 1617 27 1593 1570 1540 SP9 1772 25 1735 26 1698 26 1674 27...

Page 32: ...9 R233 R243 R245 NTC1 R209 R212 R215 R219 R227 R231 R248 R261 R208 R283 R61 R86 R87 R103 R107 R141 R203 Y1 Y2 R76 R238 R262 R8 R40 R44 R45 R46 R55 R70 R74 R75 R81 CR1 CR8 CR11 CR12 C R15 CR16 CR2 0 CR...

Page 33: ...lta T Difference between Supply and Return Temperatures DB F GAS PRESSURES Gas Inlet Pressure IN W C Gas Manifold Pressure Low Fire IN W C Gas Manifold Pressure High Fire IN W C Gas Type NG Natural Ga...

Page 34: ...34 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 35: ...35 THIS PAGE INTENTIONALLY LEFT BLANK...

Page 36: ...rchased to be directed to the feedback page GOODMAN BRAND AMANA BRAND GOODMAN BRAND AMANA BRAND PRODUCT REGISTRATION Thank you for your recent purchase Though not required to get the protection of the...

Reviews: