background image

Installation Instructions 

 

1 | P a g e  

 

v 1 . 1   ( 1 2 / 2 0 1 8 )      

TORANT LED FLOOD LIGHT   

SKU# 231078, 231079 

Rated Voltage 220-240V~ 50Hz 

 

Thank  you  for  purchasing  this  quality  MFL  product.  To  ensure  correct  function  and  safety,  please  read  and  follow  all 

instructions carefully before assembly, installation and use of this product. Please keep instructions for future reference. 

 

Warranty 

 

This luminaire is covered by a 3 year warranty. The warranty is from date of purchase, not the date of installation.   

 

If the luminaire is not assembled and installed by a licensed electrician the warranty will be void. 

 

Please retain proof of purchase and evidence of assembly and installation by a licensed electrician.   

 

Warranty will be void if there is any damage due to improper usage or modification to the luminaire. 

 

Failure to comply with the instructions in this manual may increase the risk of damage or injury and will void warranty. 

 

The use of non-tested dimmers may damage your LED luminaire and will void your warranty. 

 

Installation Requirements 

 

 

This luminaire must be assembled and installed by a licensed electrician. 

 

All wiring and installation of the luminaire must adhere to latest local and national wiring rules.   

eg. AS/NZS 3000 Electrical installations.   

 

This luminaire is a Class I product and must be earthed. 

 

Select a suitable location for installation: 

-  This fitting is protected against water penetration to IP65 standards, which is against low pressure jets of water 

from all practicable direction. This must be maintained during installation. 

-  It is suitable for indoor or outdoor use. 

-  The mounting point must support 2 times the weight of the fitting.   

 

This luminaire is dimmable and has been tested at the date of publication with the dimmers listed in the specification 

section. The use of a LED dimmer such as the Lucci LEDlux SKU# 290998 dimmer is highly recommended. 

 

NOTE: For the best dimming range, use with the Lucci LEDlux SKU# 290998 dimmer and adjust the variable 

resistor at minimum and maximum dimming positions on the dimmer during the installation. 

 

NOTE: Dimming may cause buzzing sounds or a slight flicker. There may be slight delays with the LED light start up 

or slight uneven light performance when more than one LED luminaire is linked together, switched ON or dimmed. 

This is not a product fault and as such is not covered under warranty. 

 

NOTE: Some dimmers have a minimum load of 20W. Ensure the dimmer position is on the maximum setting before 

turning on the LED light and adjust the dimmer down to your desired light level. 

 

NOTE: Testing cannot account for installation variables such as variation in mains supply voltage, cable 

capacitance, electrical noise, transients, surges and ripple control signals (commonly found in NSW & QLD). 

 

Take care not to pull any electrical wires during unpacking as this may damage the connection.   

  Lay out all the components on a smooth surface and make sure there are no components missing before assembling. 

If parts are missing, return the complete product to the place of purchase for inspection or replacement. 

 

Check whether the luminaire has been damaged during transport. Do not operate/install any product which appears 

damaged in any way. Return the complete product to the place of purchase for inspection, repair or replacement. 

 

Ensure power to the circuit you are working on has been switched OFF before commencing any electrical work. 

 

 

 

Summary of Contents for MFL TORANT 231078

Page 1: ... point must support 2 times the weight of the fitting This luminaire is dimmable and has been tested at the date of publication with the dimmers listed in the specification section The use of a LED dimmer such as the Lucci LEDlux SKU 290998 dimmer is highly recommended NOTE For the best dimming range use with the Lucci LEDlux SKU 290998 dimmer and adjust the variable resistor at minimum and maximu...

Page 2: ... Ensure the screws and anchors used are suitable for the mounting surface and the surrounding environment Step 2 4 Connect the mains supply wire to the terminal block Step 3 Mains Supply Wire Luminaire Wire Terminal block Earth Yellow Green Yellow Green or Neutral Blue or Black Blue or N Live Brown or Red Brown or L Ensure the wires are secure and no bare wires are exposed NOTE It is recommended t...

Page 3: ...e dimmer position is on the maximum setting before turning on the luminaire and adjust the dimmer down to your desired light level Buzzing sound Non tested dimmer used Check the dimmer used Ensure the dimmer used is on the list of tested dimmers in this manual Uneven light start up Dimmer position on low when switched on Ensure the dimmer position is on the maximum setting before turning on the lu...

Page 4: ...Voltage 220 240V 50Hz Rated Wattage 15W IP Rating IP 65 LED Specs 950 Lumens 3000K CRI 80 Dimmable Dimmer Information Highly Recommended Dimmers Lucci LEDlux SKU 290998 Tested Dimmers Buster Punch Dim 002 Clipsal 31E2RUDM 31E2PUDM 32E450UDM 32E450TM and 32ELEDM HPM Cat 400T Weight 1 1kg Dimensions H 95mm W 130mm Ext 144 mm ...

Reviews: