Magnum 2000

user manual

Summary of Contents for Magnum Pro 2000

Page 1: ...Magnum 2000 user manual...

Page 2: ...2000 Martin Professional A S Denmark All rights reserved No part of this manual may be reproduced in any form or by any means without permission in writing from Martin Professional A S Denmark Printe...

Page 3: ...life and reliability High pressure pump Variable smoke output Remote control unit with auto timer and memory function 0 10 V control input Slave output for control of multiple units from a single rem...

Page 4: ...fog fluid only Always ground earth the device electrically Use only a source of AC power that complies with local building and electrical codes and has both overload and ground fault protection Do not...

Page 5: ...a plug on the mains lead You will have to fit a suitable plug one that fits your local wall outlet before you can connect the machine to the mains The double isolated mains lead on the Magnum 2000 co...

Page 6: ...Other fluids may clog the heating element or spit from the nozzle To install the fluid tank 1 Place the fluid tank in the Magnum 2000 as shown on page 2 2 Remove the container cap and screw on the tan...

Page 7: ...O L UNI T The control unit is secured to the back panel by two thumbscrews It may be removed for remote control and placed in a rack or on a table To remove the control unit 1 Unscrew the thumbscrews...

Page 8: ...n you release the Smoke button smoke emission will continue for another few seconds because the fluid in the heating element is under pressure A UTO TI ME R The auto timer allows you to program output...

Page 9: ...s to pin 1 on the XLR control input and that the 0 10V output connects to pin 3 The analog control levels are shown below MULTIPLE MA CHINES Whether you operate your Magnum 2000 via the control unit o...

Page 10: ...cate on the left hand side of the PCB fuse F1 5 Replace the fuse with a new one T 10 A at 230 V T 15 A at 115 V 6 Re assemble the device before connecting to the mains No light in the POWER LED on rea...

Page 11: ...n dealer for service To reset the thermo switch Warning Before attempting any of the following ensure that the machine is disconnected from mains power and cooled down 1 Remove the fluid tank from the...

Page 12: ...V model AC voltage 115 V model AC frequency 200 260 V 100 130 V 50 60 Hz Power consumption 1700 W Maximum fluid consumption 0 2 l min Tank capacity 9 5 l 2 5 gall Warm up time 8 10 min Fuse 10 AT at 2...