background image

 

K1 HAZER

TM

 

user manual 

P/N 35010031-G
 

 

Summary of Contents for JEM K1 Hazer

Page 1: ...K1 HAZERTM user manual P N 35010031 G...

Page 2: ...Overview 11 Fast access buttons 11 Setting haze density 11 Setting fan speed 12 Auto fan mode 12 Setting Run mode 12 Setting the Timer 12 Setting the DMX base address 13 Setting the master slave link...

Page 3: ...the instructions in this manual and the machine is malfunctioning please contact Martin Service Preventing electric shocks Always ground earth the machine electrically Use only a source of AC power t...

Page 4: ...ignition such as open flames or pyrotechnic effects Do not attempt to bypass thermostatic switches fluid sensors or fuses Replace fuses only with ones of the type and rating specified in this manual f...

Page 5: ...tput directly at a person s face or at face height General warnings Read instructions before use Lisez les instructions avant l emploi Keep output 60 cm away from people and surfaces Maintenir la buse...

Page 6: ...create large scale effects in the biggest venues Congratulations on your purchase of the JEM K1 Hazer from Martin Details of the full range of Martin products are available on our website at www mart...

Page 7: ...k Warning high temperature vapour and surfaces 3 pin DMX input and link Remote control socket Main power switch Power inlet connector Digital control panel Air intake 5 pin DMX input and link Fast acc...

Page 8: ...optional remote control connect it to the REMOTE IN connector on the rear panel Turn on the main power switch located next to the power cable inlet Making haze Press either ECO PRE1 PRE2 from the Fas...

Page 9: ...installed on the power cable DANGER Make sure the power plug is correctly rated EU 230V fit a plug rated 6 amp minimum US 120V fit a plug rated 10 amp minimum When installing the plug follow the plug...

Page 10: ...rent load Turning on the power Turn on the main power switch located next to the power cable inlet and select Standby from the menu The display will show for about 5 7 minutes as the machine heats up...

Page 11: ...urns to previous state Fast Access Mode Haze and Fan settings DMX Value Equivalent CH1 CH2 Drops Fan levels by 30 relative to current values Reduce by 30 of current value Haze 5 Fan 5 30 11 Haze 50 Fa...

Page 12: ...t not hazing enable timed pulses of haze enable continuous haze Press the Enter button to store the Run setting When the mode is changed to the unit will enter a 3 minute shut down sequence before pow...

Page 13: ...he Previous Next buttons to select the option Use the Up Down buttons to select or Press the Enter button to store the link setting The machine should be set to only if it is running as a master If ru...

Page 14: ...ation for the machine Use the Previous Next buttons to select the option Use the Up Down buttons to change the option to Press the Enter button to reset all options To exit this menu if you decide not...

Page 15: ...e output on and off Press once to start haze and again to stop Timer button turns the haze timer on and off Haze level setting HAZE 0 100 Fan speed setting FAN 0 100 Timer run time off time settings 0...

Page 16: ...sa Do not however attempt to split a DMX line by using both the 3 pin and 5 pin OUT sockets For best results use cable designed for high speed digital data transmission Suitable DMX cable is available...

Page 17: ...uid it is designed for Use ONLY the Martin haze fluid designated in this manual NEVER use any other type of fluid or toxic gas may be produced You will probably also cause damage to the system that is...

Page 18: ...output nozzle remains hot for up to 10 hours after use Remove dust from the air vents with a soft brush cotton swab vacuum or compressed air Clean haze fluid residues from the output of the machine C...

Page 19: ...ddress setting incorrect Change DMX address page 13 Machine can be fired from control panel or remote control but not by DMX controller Poor connection in DMX line Check DMX cables and connections Haz...

Page 20: ...detected an error with its calibration settings and will not operate Call Martin Service The air pump is not working This indicates a fault Turn the machine off and call Martin Service The fluid pump...

Page 21: ...K1 Haze Connections DMX 3 or 5 pin XLR Remote machine link 3 pin XLR AC power PowerCon Electrical AC voltage 120V 230V 50 60Hz Main fuse 120V US version 10AT Main fuse 230V EU version 5AT Power usage...

Page 22: ...power cable 18AWG with Nema 5 15 plug to PowerCoN male connector UL approved 1 x 2 5L fluid container empty Ordering information Martin JEM K1 Hazer 120V 92225900 Martin JEM K1 Hazer 230V 92225901 JEM...

Page 23: ...Notes 23 Notes...

Page 24: ...Martin Professional A S Olof Palmes All 18 DK 8200 Aarhus N Phone 45 87 40 00 00 Internet www martin com...

Reviews: