background image

OMI6912A

OMI6918A

OMI6915A

OMI6921A

OMI6916A

For use with the following:

Your Industrial Control Solutions Source

_____________________

www.maplesystems.com

Maple Systems, Inc.   |   808 134

th

 St. SW, Suite 120, Everett, WA 98204   |  425.745.3229

OMI Operations Manual 

OMI6900 Light Industrial Panel PC Series

Summary of Contents for OMI6912A

Page 1: ...or use with the following Your Industrial Control Solutions Source _____________________ www maplesystems com Maple Systems Inc 808 134th St SW Suite 120 Everett WA 98204 425 745 3229 OMI Operations M...

Page 2: ...1A Dimensions 13 OMI6921A Specifications 14 OVERVIEW OF OMI6900 SERIES 15 Front View of OMI6900 Series 15 Rear View of OMI6912 15 Rear View of OMI6915 16 Rear View of OMI6916 16 Rear View of OMI6918 1...

Page 3: ...29 Email support maplesystems com Web http www maplesystems com UNPACKING THE UNIT Carefully unpack the OMI6900 Check all material in the container against the packing list Maple Systems will not acce...

Page 4: ...uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual it may cause interference to radio communications It has been tested and found to c...

Page 5: ...ICATIONS The following section contains the Dimensions and Specifications for the OMI6900 series Light Industrial Panel PCs OMI6912A Dimensions A Power Connector B VESA 100 x 100 mm Screw Holes C Line...

Page 6: ...wire resistive touch Interface USB Touch Screen Light Transmission 80 Input Voltage 9 36 VDC Input Current 0 5 2 2 A Electrical Input Power 19 6 W Construction Silver aluminum front bezel and chassis...

Page 7: ...900 Series 7 OMI Operations Manual OMI6900 Series 7 OMI6915A Dimensions A Power Connector B VESA 100 x 100 mm Screw Holes C Line Out D Remote Power Switch Connector E USB 3 0 Host Ports F Gigabit Ethe...

Page 8: ...resistive touch Interface USB Touch Screen Light Transmission 80 Input Voltage 9 36 VDC Input Current 0 8 3 3 A Electrical Input Power 29 4 W Construction Silver aluminum front bezel and chassis Rati...

Page 9: ...900 Series 9 OMI Operations Manual OMI6900 Series 9 OMI6916A Dimensions A Power Connector B VESA 100 x 100 mm Screw Holes C Line Out D Remote Power Switch Connector E USB 3 0 Host Ports F Gigabit Ethe...

Page 10: ...re resistive touch Interface USB Touch Screen Light Transmission 80 Input Voltage 9 36 VDC Input Current 0 9 3 4 A Electrical Input Power 31 0 W Construction Silver aluminum front bezel and chassis Ra...

Page 11: ...00 Series 11 OMI Operations Manual OMI6900 Series 11 OMI6918A Dimensions A Power Connector B VESA 100 x 100 mm Screw Holes C Line Out D Remote Power Switch Connector E USB 3 0 Host Ports F Gigabit Eth...

Page 12: ...re resistive touch Interface USB Touch Screen Light Transmission 80 Input Voltage 9 36 VDC Input Current 1 2 4 6 A Electrical Input Power 41 6 W Construction Silver aluminum front bezel and chassis Ra...

Page 13: ...00 Series 13 OMI Operations Manual OMI6900 Series 13 OMI6921A Dimensions A Power Connector B VESA 100 x 100 mm Screw Holes C Line Out D Remote Power Switch Connector E USB 3 0 Host Ports F Gigabit Eth...

Page 14: ...resistive touch Interface USB Touch Screen Light Transmission 80 Input Voltage 9 36 VDC Input Current 0 9 3 7 A Electrical Input Power 33 3 W Construction Silver aluminum front bezel and chassis Rati...

Page 15: ...IEW OF OMI6900 SERIES The OMI6900 Series is available in 12 1 15 15 6 18 5 and 21 5 screen sizes The OMI6900 is a compact flat panel touch screen and is powered by the Intel 4th Gen Core i5 CPU proces...

Page 16: ...OMI Operations Manual OMI6900 Series 16 OMI Operations Manual OMI6900 Series 16 Rear View of OMI6915 Rear View of OMI6916...

Page 17: ...OMI Operations Manual OMI6900 Series 17 OMI Operations Manual OMI6900 Series 17 Rear View of OMI6918 Rear View of OMI6921...

Page 18: ...nnector Type DE9P male serial ports COM1 COM2 Pin RS 232 Default RS422 RS485 RS232 1 DCD 422_RX NC DCD 2 RXD 422_RX NC RXD 3 TXD 422_TX 485 TXD 4 DTR 422_TX 485 DTR 5 GND GND GND GND 6 DSR NC NC DSR 7...

Page 19: ...SB OMI6900 models have 2 USB 3 0 type A ports Note USB 3 0 allows data transfers up to 5000 Mb s full speed and low speed signaling The current limit is 2 0A LAN1 and LAN2 Standard 10 100 1000M RJ 45...

Page 20: ...COM1 FUNCTION 1 Using a 1 Phillips screwdriver remove the 2 Phillips screws indicated in the figure 2 Remove the storage cover by lifting it out of the unit 3 Using a 1 Phillips screwdriver remove the...

Page 21: ...M1 Function Switch Setting label and or the following chart to set the DIP switches to the desired RS 232 RS 422 or RS 485 communication mode Function S_422 switches 1 5 S_232 all switches RS232 Defau...

Page 22: ...6900 Series 22 7 Replace the storage cover and secure it with the screws removed in step 1 8 Enter the BIOS Setup Utility to select the desire communication mode by pressing Delete key during POST The...

Page 23: ...n mode as follows Advance F81216 Second Super IO Configuration Super IO chip F81216SEC Second IO Serial Port 0 Configuration UART1 Mode Selection RS 232 RS 485 RS 422 Remote power switch configuration...

Page 24: ...w retaining the storage bracket Then carefully slide the bracket out of the unit 4 The DIP switches and switch settings are now visible 5 Reference the COM1 Function Switch Setting label and the chart...

Page 25: ...900 Series 25 OMI Operations Manual OMI6900 Series 25 6 Slide the bracket and storage device into the OMI securing it with the screw removed in step 3 7 Replace the storage cover and secure it with th...

Page 26: ...addition to VESA mounting the OMI can be mounted in a panel using the mounting holes located on the sides and top of the unit Use the included clamps to fasten the OMI6900 to a panel cut out to the p...

Page 27: ...e application setup exe file to begin driver installation Follow the instructional prompts on the screen We recommend that you restart your computer when prompted and after completion of all driver in...

Page 28: ...dard Calibration The simpler of the two methods this method can be used for most touch screen calibrations required Advanced Calibration As your OMI6900 ages the touch screen may require finer adjustm...

Page 29: ...ed squares in sequence After the fifth red point calibration is complete Plot calibration data this option will display a linearity comparison graph after calibration is complete The blue lines show l...

Page 30: ...ep occurs when pen is lifted up Beep on both beep occurs when comes down and lifted up Beep Frequency modifies sound frequency Beep Duration modifies sound duration 3 Cursor Stabilizer Enable the func...

Page 31: ...res long term stability that critical production systems require by updating only necessary operating system components with significantly fewer update interruptions Included Apps Microsoft Edge Web B...

Page 32: ...00 Series 32 OMI Operations Manual OMI6900 Series 32 1010 1070 Rev 02 Maple Systems Inc 808 134th St SW Suite 120 Everett WA 98204 425 745 3229 Your Industrial Control Solutions Source _______________...