INSTALLATION 

INSTRUCTIONS                             

The Lo Profile Deco Extractor & Humidity Range - LP / DECO 100, 120, 150 

Wiring

1. Switch off mains supply before making electrical 

connections. If in any doubt contact a qualified 
electrician.

2. These units are for fixed wiring only. A flexible cord 

must not be used. All wiring must be fixed securely 
and the cable to the fan should be a minimum of 
1mm

2

 in section. All wiring must comply with current 

I.E.E. Regulations or local regulations if outside the 
UK.

3. A double pole fused spur having contact separation 

of at least 3mm in all poles must be used and fitted 
with a 3A fuse.

4. This fan is double insulated and does not require 

an earth connection.

5. The fan should not be accessible to a person using 

either the shower or the bath. 

Location

1. When installing fan through an external wall, an 

external wall grille must be fitted at all times.

2. For best results this Extractor Fan should be fitted 

as high on the wall as possible, or if preferred, on 
the ceiling. Note: Pullcord models should not be 
installed in a ceiling.

3. Where ducted fans are used to handle moisture-

laden air, such as a bathroom, a condensation 
trap should be fitted in any vertical exhaust ducts. 
Horizontal ducts should be arranged to slope 
slightly away from the fan. Ducts passing through 
cold voids must be suitably insulated.

4. Do not install the unit within a shower cubicle 

or anywhere else where there is a risk of being 
sprayed with water (Please see our range of 
showerfans for these installations.). 

5. If the fan is installed in a room containing a fuel 

burning appliance, the installer must ensure that 
the air replacement is adequate for both the fan 
and the fuel burning appliance.

Switch off mains supply before making any electrical connections.
Installation must be supervised by a qualified electrician.
A double pole fused spur having contact separation of at least 3mm in 

all pole must be used and fitted with a 3A fuse. 
This appliance can be used by children aged from 8 years and above 

and persons with reduced physical, sensory and mental capabilities or 

lack of experience and knowledge if they have been given supervision 

or instruction concerning the use of the appliance in a safe way and 

understand the hazards involved. 
Children shall not play with the appliance. 
Cleaning and user maintenance shall not be made by children  

without supervision.
Precautions must be taken to avoid the back-flow of gases into the 

room from the open flue of gas or other open-fire appliances when 

mounted in outside windows or walls.
Fan must be disconnected from electrical power before any 

maintenance is carried out.

Summary of Contents for LP 100

Page 1: ...hould be arranged to slope slightly away from the fan Ducts passing through cold voids must be suitably insulated 4 Do not install the unit within a shower cubicle or anywhere else where there is a risk of being sprayed with water Please see our range of showerfans for these installations 5 If the fan is installed in a room containing a fuel burning appliance the installer must ensure that the air...

Page 2: ...on as marked Allow an extra 230mm 9 protruding to facilitate connection SECURE CORD GRIP 9mm 6mm 9mm 9 m m 2 3 POWER SUPPLY PO W ER SU PP LY Terminal 1 live supply in Terminal 2 neutral supply in TRIM CABLE TERMINAL BLOCK POWER CABLE ENTRY MOTOR WIRE POWER CABLE COVER SCREW FIXING HOLES 3 AMP DOUBLE POLE FUSED SPUR _ NEUTRAL LIVE REMOTE PULLCORD SWITCH LIGHT SWITCH HOLES FIXING HOLES Fixing clip C...

Page 3: ...e increased by firstly switching off the power to the fan Remove the cover and the timer cover as detailed in diagram 2A Insert a small screwdriver into the slot marked in Diagram 2A and turn clockwise to reduce the time and anti clockwise to increase the time Only adjust with power switched off the timer will run for is 30 seconds and the maximum is about 20 minutes NB Timer delay is adjustable a...

Page 4: ...duced to a normal level about 65 Connect to electrical supply as shown in diagram 3 Neutral Switched Live Spare Permanent Live PCB Board Cover Motor Wire Humidity operated time delay control Diagram 3 Time delays humidity over risde operation Terminal 1 1 Neutral Terminal 2 2 Switch live Supply Terminal 3 3 Spare Terminal 4 4 Permanent Supply 077286 LP100 LP120 T Max 40 C Rated 220 240V 50Hz 20W q...

Reviews: