background image

Summary of Contents for RKM

Page 1: ......

Page 2: ...2 1 Description 3 2 Design 3 3 Placement and Assembly 4 4 Dimensions 5 5 Material surface protection 9 6 Product data 9 7 Logistic terms 9 8 Warranty 9 9 Installation 9 ...

Page 3: ...lectrical items the temperature range shall be restricted acc to the temperature range of the electrical items used Then the group of non explosiveness of the damper with electrical items depends on the non explosive design of the electrical items installed on the damper The electrical devices installed together with the damper must be made in the design corresponding to the given zone The princip...

Page 4: ...allation in air conditioning piping The operation position is arbitrary The minimum space for the control device is 200 mm in blade rotation axis When assembling round dampers into the piping respect the overlap of open blade a tab 4 3 1 ...

Page 5: ... with 8 x 8 mm cross section onto which the actuator is to be fixed either directly or with the help of a reducer The pin exceeds the damper flange by 30 mm Position 1 Damper body 2 Divider 3 Damper blade 4 Control mechanism 5 Control lever manual 6 Stiffening bolt ...

Page 6: ...6 The damper for actuator attachment is fitted with a square pin with 10x10 mm diameter and 50 mm length Position 1 Damper body 2 Damper blade 3 Pin 4 Control lever manual 5 Control lever mechanical ...

Page 7: ...d a 150 110 4 79 240 150 130 4 99 240 150 140 4 109 240 150 155 8 124 240 150 170 8 139 240 149 240 150 195 8 159 240 150 10 215 8 179 240 150 20 235 8 199 240 150 32 5 260 8 224 240 150 45 285 8 249 240 150 60 315 8 279 240 15 150 70 335 12 299 240 25 309 240 30 150 77 5 350 12 314 240 32 150 97 5 390 12 354 240 52 200 95 445 12 399 300 45 200 120 495 12 449 300 70 200 145 545 16 499 300 95 200 1...

Page 8: ...8 flanges with 30 mm width are fitted with oval holes in corners Round piping with flanges flanges acc to EN 12 0505 Spiro piping with lip seal ...

Page 9: ...st be stored in covered buildings in an environment without aggressive vapours gases and dust A temperature in a range of 5 C and 40 C and a relative humidity of max 80 must be maintained in the buildings For handling during storage the dampers must be protected against mechanical damage The manufacturer provides a warranty of 24 months from the date of dispatch for the dampers If the dampers are ...

Page 10: ...reserves the right for innovations of the product For actual product information see www mandik com MANDÍK a s Dobříšská 550 26724 Hostomice Czech Republic Tel 420 311 706 706 E Mail mandik mandik cz www mandik com ...

Reviews:

Related manuals for RKM