background image

PORTABLE GENERATOR

MPG 6600

OPERATING/PARTS MANUAL

Summary of Contents for MPG 6600

Page 1: ...PORTABLE GENERATOR MPG 6600 OPERATING PARTS MANUAL...

Page 2: ...copy of this manual with the unit at all times Additional copies are available from Magnum Products LLC or can be found at www m p llc com An engine operator s manual was also supplied with the unit a...

Page 3: ...ADS 10 GFCITESTINSTRUCTIONS 10 PREVENTION OF OVERLOAD 10 WATTAGE CONSUMPTION OF EQUIPMENT 11 USE OF EXTENSION CORDS 11 EXTENSION CORD SELECTION CHART 12 ADDING ENGINE OIL 12 ADDING GASOLINE 12 STARTIN...

Page 4: ...xist during operation 1 Noticeable change in engine speed 2 Loss of electrical output 3 Equipment connected to the generator overheats 4 Sparking occurs 5 Engine misfires or there is excessive engine...

Page 5: ...Sulfuric acid can cause eye damage burn flesh or eat holes in clothing Protective eye wear and clothing are neces sary when working on or around the battery Always disconnect the NEGATIVE battery cabl...

Page 6: ...These decals provide important operating instructions and warn of dangers and hazards Replace any missing or hard to read decals and use care when washing or cleaning the unit Decal placement and par...

Page 7: ...18Ah Weights and Dimensions Dry Weight 236 0 lbs 107 kg 241 0 lbs 109 kg Operating Weight 277 0 lbs 126 kg 282 lbs 128 kg Dry Weight w Wheel Kit Option 263 0 lbs 119 kg 268 0 lbs 122 kg Operating Wei...

Page 8: ...OFF VALVE UNDER TANK RECOIL STARTER CONTROL PANEL ENGINE STARTING BATTERY BATTERY TRAY OPTIONAL ENGINE EXHAUST WHEEL KIT OPTIONAL HANDLE WHEEL KIT OPTIONAL CENTRAL LIFTING EYE AIR FILTER HOUSING ENGIN...

Page 9: ...ic engine starting option D VOLTAGE SWITCH This switch changes voltage on the L14 30R outlet from 120V to 240V E MAIN CIRCUIT BREAKER This unit contains a 28Acircuit breaker F GFCI TEST MODULE This mo...

Page 10: ...ALWAYS test GFCI outlets before connecting any loads to the generator The device green LED is ON and circuit breaker is at ON position 1 Press the TEST button The green LED should go out and the red L...

Page 11: ...BTU 400 Oil Fired Space Heater 85 000 BTU 225 Oil Fired Space Heater 30 000 BTU 150 Paint Sprayer Airless 1 3 hp 600 Paint Sprayer Airless handheld 150 Radio 50 to 200 Submersible Pump 1 1 2 hp 2800...

Page 12: ...2 14 16 5 10 15 20 600 1200 1800 2400 LOAD IN WATTS VOLTS 120 240 120 240 120 240 120 240 225 455 115 225 75 151 57 110 140 285 70 140 47 95 36 70 90 180 45 90 30 60 60 120 3 Tighten the gasoline cap...

Page 13: ...on cords For the 120 240V NEMA L4 30A outlet select the proper output voltage for the outlet and the equipment that will be connected to it 2 Switch the main circuit breaker on The equipment connected...

Page 14: ...ow stabilization of the internal temperatures of the engine and generator 4 Turn the unit off 5 Close the fuel shut off valve 1 Shut off all loads and unplug electrical loads from the control panel re...

Page 15: ...il including special operating conditions such as a change in season or climate Service the generator more frequently when used in dusty areas LIFTING THE GENERATOR ITEM DAILY 20 HRS 50 HRS 100 HRS 30...

Page 16: ...r reconstituer la puissance de circuit WARNING ADVERTENCIA AVERTISSEMENT Improper connection of generator to a building s electrical system can allow electrical current from the generator to backfeed...

Page 17: ...tch rocker on off 11 65874 1 Switch rocker idle select 12 60181 4 Screw M3 0 50X5panphil 13 60398 4 Screw 6 32X 312panphil 14 60046 4 Screw 6 32X 750 pan phil G2 15 60161 6 Nut 250 20 hex 16 19211 1 T...

Page 18: ...18 1 18 3 2 21 4 5 6 7 6 8 22 19 34 33 38 37 9 10 11 13 36 13 35 14 13 10 12 34 33 15 16 17 31 32 19 20 20 23 22 19 34 34 30 29 30 22 28 26 27 41 40 39 43 9 25 24 FRAME AND FUEL TANK ASSEMBLY 42...

Page 19: ...er 500 flat 03TH nylon 21 24920B 1 Bracket lift eye 22 60307 8 Nut 500 13 nylock 23 61147 2 Nut 312 18 U clip G5 ZY long type 24 60168 1 Screw 312 18X 750 hx hd G5 25 60095 1 Nut 312 18 ser flg G5 cas...

Page 20: ...ME TO FRAME TO FRAME 1 2 13 1 2 3 4 5 10 2 9 1 2 7 6 3 3 39 11 15 16 14 12 17 18 19 8 24 26 25 18 19 19 24 17 23 20 22 21 17 27 19 18 18 30 29 28 31 32 33 34 35 36 37 33 38 40 40 41 ENGINE AND GENERAT...

Page 21: ...Screw 500 13X1 000hxhd 24 60478 2 Screw 375 16X2 000 hx hd G5 25 24923B 1 Bracket mount 26 60205 2 Screw 375 16X1 000hxhd 27 Terminal ground 28 12927 1 Nut 375 16 wing 316 SS 29 60352 4 Screw 375 16X...

Page 22: ...14 15 W X X GRN YEL WHT WHT WHT BLK YEL WHT RED BLK BLU RED BLK BLU WHT RED RED BLK BLK BLK BLK BLK BLK BLK BLU BLU GRN RD WT RD WT GRN BLU WIRES MUST BE TWISTED TOGETHER GOING THRU CT 2 6 10 14 3 7 1...

Page 23: ...LE RUN MODULE GRN RED BLU ORN IDLE RUN SOLENOID SHUTDOWN SOLENOID COIL OIL LEVEL SWITCH OIL ALERT UNIT CHARGE COIL RECTIFIER START SWITCH STARTER GENERATOR WHT BLK WHT BLK GRN RED ORN GRY GRY BLK BLK...

Page 24: ...REV C PART NO 26128 02 04 09...

Reviews: