background image

  

 

 

 

Magneti Marelli Aftermarket Spółka z.o.o. 

Plac Pod Lipami 5, 40-476 Katowice 

Tel.: + 48 (032) 6036107, Faks: + 48 (032) 603-61-08 

e-mail

[email protected] 

www.magnetimarelli-checkstar.pl 

Wheel balancer MM-WB1024  

User’s manual 

007935017275

 

Summary of Contents for MM-WB1024

Page 1: ...ftermarket Sp ka z o o Plac Pod Lipami 5 40 476 Katowice Tel 48 032 6036107 Faks 48 032 603 61 08 e mail checkstar magnetimarelli com www magnetimarelli checkstar pl Wheel balancer MM WB1024 User s ma...

Page 2: ...er the machine parameter is comforted before leave factory we sticked a label inside the machine cabinet the position is showed as the following sketch picture 2 1 1 2 Accuracy parameter inputing meth...

Page 3: ...e or decrease the value Press key a again to exit the program 2 complete shaft adjustment 2 1 Piezoelectric sensor assembly disassembly assembly adjusting and maintenance method warning the following...

Page 4: ...3 and 4 by hand by half a turn with the spanner if necessary 5 Refit the washers cup springs and nuts 1 and 2 Tighten the nuts fully in order to fully regain the elasticity of the cup springs This wi...

Page 5: ...embly Picture 3 4 showing that complete shaft and machine body form an angle less than 90 degree this is incorrect assembly Please adjust the nut and Picture 3 5 showing that complete shaft and machin...

Page 6: ...maintenance method 3 1 Diameter sensor and distance scale sensor Please check if the following parts with red circle marked loose check if the screw in the red marked loose 2 please refer to the photo...

Page 7: ...When you install the Gauge sensor again please screw to the Clockwise twist to the limit position then install as the following photo...

Page 8: ...3 2 Width scale sensor assembly disassembly and adjusting method First step when installing the diameter guage sensor the handle bar must be kept as this station whichstick the complete shaft tightly...

Page 9: ...Second step...

Page 10: ...Fourth step...

Page 11: ...First step...

Page 12: ...Third step Second step follow as the direction and following rotate screw dirver back to 90 angle the as follow step First following direction and rotate screw dirver to the end...

Page 13: ...nsor Pls take off the two screws remark with red circle part then the user can take off the photoelectric sensor show as below picture Fig5 1 Pls do not take off the blue box screws due to the accurac...

Page 14: ...ase make sure the microswitch can pushed by the cross round screw and cut off protection function Magneti Marelli Aftermarket Sp ka z o o Plac Pod Lipami 5 40 476 Katowice Tel 48 032 6036107 Faks 48 0...

Reviews: