background image

MABISMist

II

Ultrasonic Nebulizer

Guidebook

Model 40-270-000

Please read this guidebook 

completely before operating this unit.

The MABISMist™ II Ultrasonic Nebulizer is an ultrasonic nebulizer that is intended 

for use in the treatment of asthma, COPD and other respiratory ailments in which an

aerosolized medication is required during therapy. The MABISMist™ II Ultrasonic 

Nebulizer is not intended for use with Pentamidine. It is intended for single patient use.

Federal (U.S.A.) law restricts this device to sale by, or on the order of, a licensed physician.

English • Spanish

TOLL-FREE CUSTOMER CARE HELPLINE:

1-800-622-4714

Summary of Contents for 40-270-000 MABISMist II

Page 1: ...ed for use in the treatment of asthma COPD and other respiratory ailments in which an aerosolized medication is required during therapy The MABISMist II Ultrasonic Nebulizer is not intended for use with Pentamidine It is intended for single patient use Federal U S A law restricts this device to sale by or on the order of a licensed physician English Spanish TOLL FREE CUSTOMER CARE HELPLINE 1 800 6...

Page 2: ...ar use or purpose whether or not the use or purpose has been disclosed to MABIS Healthcare in specifications drawings or otherwise and whether or not MABIS Healthcare s products are specifically designed and or manufactured by MABIS Healthcare for the buyer s use or purposes except for the limited warranty stated above MABIS will not be responsible for any indirect incidental special consequential...

Page 3: ... unit Do not attempt to remove the transfer cone located in the base of the water reservoir If any abnormality occurs discontinue use until the unit has been examined and repaired The unit should not be left unattended while plugged in Do not use solutions other than water in the reservoir It may damage the transducer Do not tilt or shake the unit when in operation Opening the cover during operati...

Page 4: ...high humidity Avoid placing the battery on metal or wet surfaces or inside a metal box This may short circuit the battery s positive and negative contact causing the battery to heat up or explode Cleaning Procedures It is important to clean your Nebulizer before the first time it is used and after each use Remember Disconnect the unit from the electrical outlet and never immerse the unit in water ...

Page 5: ...east 4 ml Only use medications under the instructions of your physician Using the AC adapter or battery pack Your Nebulizer operates by use of the AC adapter or battery pack both included with your Nebulizer Using the AC adapter 1 Insert the adapter plug into the unit s AC port Fig 4 2 Plug the adapter into a standard AC outlet NOTE It is not necessary to install the bat tery pack when using AC vo...

Page 6: ...w settings High Medium and Low 2 Based on instructions from your physician and or respiratory therapist press the airflow button to adjust the airflow volume The Airflow Volume Indicator Lights will show the level high medium or low selected Fig 10 To begin a treatment 1 Follow the instructions provided by your physician and or respiratory therapist 2 Your Nebulizer is designed to start at a lower...

Page 7: ...firmly and properly properly mounted to the motor shaft A flashing red This is normal see Using the light on the Battery Pack The flashing bottom lamp light indicates proper AC when the AC connection and will change to adapter is green when the battery is connected fully charged The top light The battery needs to be changed from charged Nebulization will green to red decrease and then cease during...

Page 8: ... Forest IL 60045 USA Toll Free Customer Care Helpline 800 622 4714 www mabis net E mail nebinfo mabis net Phone 847 680 6811 Fax 847 680 9646 8 Unit Specifications Name and model number MABISMist II Ultrasonic Nebulizer 40 270 000 Power 100 120 VAC or 220 240 VAC 50 60 Hz Power Consumption Approximately 10W Ultrasonic Frequency 2 5 MHz Nebulization 3 speed adjustable Partical Size 5 m MMAD Medicin...