background image

 

 

 

 

 

User Manual 

MagniLink TAB 

LVI America Inc. 

302 Saunders Road, Suite 200 

Phone: (888) 781-7811 

[email protected] 

Riverwoods, IL 60015, USA 

 

www.lviamerica.com 

LVI Low Vision International 

Verkstadsgatan 5 

Tel: +46 470-727700 

[email protected] 

SE-352 46 Växjö 

Faks: +46 470-727725 

www.lvi.se 

Summary of Contents for MagniLink TAB

Page 1: ...a Inc 302 Saunders Road Suite 200 Phone 888 781 7811 info lviamerica com Riverwoods IL 60015 USA www lviamerica com LVI Low Vision International Verkstadsgatan 5 Tel 46 470 727700 info lvi se SE 352 4...

Page 2: ......

Page 3: ...formation 6 4 Unpacking 8 4 1 Packaging 8 5 Hardware 9 5 1 Stand 9 5 2 Tablet computer 10 5 3 Distance camera 11 5 4 Installation 12 6 Software 13 6 1 Functions via menus 13 6 2 Functions via gestures...

Page 4: ...ith ISO 9001 and environmentally certified in accordance with ISO 14001 The information in this manual has been carefully checked and is believed to be accurate However LVI assumes no responsibility f...

Page 5: ...a system with a tablet computer and stand developed to make everyday life easier for visually impaired people The system offers autofocus several artificial colours and the ability to set the magnifi...

Page 6: ...ly use the power adaptor supplied with the product Using an incorrect type of power adapter may cause damage to the system Never operate the product if it has been exposed to water or other liquids Da...

Page 7: ...collapsing the system Do not rely 100 per cent on the results of an OCR conversion the OCR engine can misinterpret the text This is particularly important to bear in mind when processing sensitive in...

Page 8: ...he MagniLink TAB and remove the packaging parts 4 1 Packaging The packaging consists of the following packaging material LVI recommends that the packaging be kept in case you have to return the system...

Page 9: ...lder for a tablet computer The arm of the stand also functions as a handle when collapsing and moving the system The stand also contains an attachment for a distance camera If the tablet is to be put...

Page 10: ...f type Microsoft Surface Pro 1 Power adapter port 2 USB port 3 USB C or Mini DisplayPort depending on model 4 Camera 5 Volume control 6 On Off button Press to start To enter standby mode press and rel...

Page 11: ...User Manual 7945369d MagniLink TAB 11 5 3 Distance camera The distance camera is connected to the tablet computer using a USB cable The camera lens can be folded down if you wish to view an object fr...

Page 12: ...your seat 2 Take hold of the arm of the stand and manipulate it into the desired position 3 Connect the power adaptor to the port on the left side of the tablet 4 Place the distance camera on the rig...

Page 13: ...ware press and hold five fingers on the screen to exit fullscreen mode Then tap the x in the top right hand corner LVI accepts no responsibility for conflicts that may arise when users installs third...

Page 14: ...x opens A file name today s date and time is suggested automatically Press Save to save with the suggested name If you wish to save the video in a different folder or with another name it is possible...

Page 15: ...ours and greyscale Switch between artificial colours By pressing with two fingers cycle backwards between the artificial colours Increase brightness or contrast Decrease brightness or contrast Mirror...

Page 16: ...e name today s date and time is suggested automatically It is possible to save the text as an RTF rtf or Zip file Open the notes tool One press with two fingers opens it together with the relevant doc...

Page 17: ...display modes available are page view row view word view image view image and word and image and row Increase font size Decrease font size Open a submenu with the following four buttons Switch between...

Page 18: ...witch fullscreen Pinch Change magnification Rotate two fingers Rotate the image Drag one finger Pan through the image Drag two fingers horizontally Change contrast level Drag two fingers vertically Ch...

Page 19: ...rds Shift F2 Positive colours backwards F3 Negative colours forwards Shift F3 Negative colours backwards Up arrow Increase magnification Down arrow Reduce magnification Ctrl J Autofocus on off Not pos...

Page 20: ...ified Not possible with the distance camera D Pan right Only possible if the image is magnified Not possible with the distance camera W Pan up Only possible if the image is magnified Not possible with...

Page 21: ...5 Switch reading mode Page Down Next page If several pages have been scanned you move to the next page Page Up Previous page If several pages have been scanned you move to the previous page 8 Reduce...

Page 22: ...licking a picture you can navigate to it You can delete an image by clicking in the upper right corner A surface where you can draw enlarge and pan in the picture The buttons in the menu bar have the...

Page 23: ...highlighter Press and hold opens a dialogue where you can choose the colour and size Insert text Press and hold opens a dialogue where you can choose the colour size and font After inserting text you...

Page 24: ...MagniLink TAB 24 User Manual 7945369d MagniLink TAB Start reading Stop reading Read previous Read next Go to settings...

Page 25: ...cation information and alternative settings You can resize the settings menus by placing two fingers on the screen and separating them or moving them towards each other 6 5 1 About the application Inf...

Page 26: ...lour is applied to both the settings menu and the menus in camera and OCR mode White Text Check here for white text and white symbols in the menus Black Text Check here for black text and black symbol...

Page 27: ...the rear camera is compensated for in the video Front camera When this is deselected it is not possible to switch to the front camera It is not possible to deselect this if the rear camera is deselect...

Page 28: ...g the sound level of the voice Speaking speed Setting the speaking speed Start speech after OCR If this box is ticked text will automatically be read aloud after an image has been OCR processed Read c...

Page 29: ...can be changed To change a short cut command tab to the command that is to be changed and enter the new keyboard combination If a combination already being used for another command is entered the oth...

Page 30: ...imum of 12 point is recommended for the lowest magnification on the reading camera Avoid glossy paper as this results in reflections in the image This impairs the results of the OCR conversion If you...

Page 31: ...o become numb legs should be at an angle of 90 degrees and you should rest your feet on the floor The table should be at a height at which you can rest your lower arm horizontally on it It is importan...

Page 32: ...Weight 2 2 kg Distance camera Magnifying area 0 8 80x Height 33 cm Weight 700 g Refresh rate 60 Hz Length of camera and arm 620 mm Tablet computer Type Microsoft Surface Pro Weight 800 g Screen size...

Page 33: ...d at a suitable collection centre for the recycling of electrical and electronic equipment By ensuring that this product is properly taken care of you are helping to prevent the negative impact on hea...

Page 34: ...MagniLink TAB 34 User Manual 7945369d MagniLink TAB 9 Declaration of Conformity...

Page 35: ...nctions via gestures 18 Functions via menus 13 Functions via the keyboard 19 Gestures 29 Hardware 9 Information 6 Information and settings window 25 Installation 12 Introduction to MagniLink TAB 5 Not...

Reviews: