background image

INSTALLATION INSTRUCTIONS

Lumascape Lighting Industries Pty Ltd

38-44 Enterprise Street, Cleveland, QLD 4163, Australia

PO Box 1875, Cleveland D.C., QLD 4163, Australia

  07 3286 2299

F

   07 3286 6599

E

   [email protected]

W

 www.lumascape.com.au 

IN0039 - 19 May 2015

Copyright ©2015 Lumascape Lighting Industries Pty. Ltd.   ABN 21 010 572 773

www.lumascape.com.au

Power supply must be isolated prior to connection 

or disconnection of cables. Failure to do so will 

result in damage to the luminaire components.

1.

Installation Preparation
To aid installation of the cable the number of elbows 
and bends should be kept to a bare minimum. Also, 
using 25 mm conduit is highly recommended. Check 
cable length required, taking into account voltage 
drop and distance to transformer. NOTE: In Australia, 
each luminaire must be installed as detailed in 
AS3000 Clause 6.4.4.5

2.

Installation Preparation
Locate niche in pool and wire to 
reinforcing bars.  
The 20 mm conduit entry 
should be at top of niche 
(Figure 
1). Although some variation is 
accommodated by the outer cover 
system on the luminaire, care 
should be taken to position the 
niche level and to allow for pool 
finishing materials.

fibreboard shield

finished surface

reinforcing bars

concrete

AVOID HIGH

CHLORINE LEVELS

NO POWER 

TOOLS

WARNING

DANGER

ISOLATE LUMINAIRE FROM POWER

Failure to isolate power 

supply before installation or 

maintenance may result in 

fire, serious injury, electric 

shock, death and may 

damage the luminaire.

Opening luminaire will viod warranty

The luminaire should only be used 

complete with its protective  

shield (cover)

Do not shorten, interfere or 

disconnect cable from luminaire

Warranty will be void if cable 

assembly is tampered with

WARNING

Figure 1

INSTALL AWAY FROM

OTHER HEAT SOURCES

UNDERWATER

LS333ANS-2LED & LS333AS-LED 

Underwater Luminaire

Warranty void if not installed as per installation instructions

  

N653

MODEL LS333ANS-2LED & LS333AS-2LED

INSTALLATION TYPE Pre Install

IP RATING IP68

SUPPLY VOLTAGE 24 V DC Ripple Free Supply

12 V AC Magnetic Transformer

INSTRUCTIONS COVER Single Colour

Single Colour Dimming
RGB (Integral & Remote Driver)

NO POWER 

TOOLS

KEEP ELECTRONICS FREE 

FROM DIRT AND MOISTURE

tighten gland

tapped brackets

niche adjustment ring

luminaire

face plate

3.

Run Conduit & Water Proof
Connect conduit to conduit entry with suitable 
conduit sealant. Use supplied adaptor if necessary. 
Run the conduit to  the power supply above water 
level and ventilate to prevent siphoning.

7.

Terminate Luminaire
Thread cable through adjustment ring and firmly 
tighten cable gland on the inside of niche to seal 
cable entry (Figure 2).  Connect to a suitable 
power supply in accordance with local wiring 
rules for connection and location of supply. 
Where it is necessary to joint cables underwater 
the connections and cables must be IP68 rated.

8.

Test Luminaire
Test the luminaire for correct operation.

Important Note
Do not locate luminaire near heat sources.
Chlorine levels must be kept below 4 parts per 
million. Higher levels may cause corrosion to the 
luminaire and void warranty.

10.

9.

Install Luminaire
Fix adjustment ring to niche with screws. Coil 
free cable inside niche and install luminaire 
by screwing long outer cover screws into 
adjustment ring (Figure 3). Coil cable inside 
luminaire with care. Do not double coils over, or 
luminaire will be difficult to remove from niche.

4.

Install Temporay Shield on Niche 
Fit fibreboard shield to opening of 
niche before concreting (Figure 1). 
Ensure no concrete enters niche.

5.

Concrete-in Niche
Encase niche and conduit in concrete. Once in 
place, finish surface of pool flush with front of 
niche.

6.

Concrete-in Niche
Feed cable into niche, allowing sufficient free 
cable in niche to allow the luminaire to be placed 
on the poolside for re-lamping and maintenance. 
A maximum of 1.3 m of cable can be coiled 
inside the niche.

Figure 3