IMPORTANT

 

•  READ THESE INSTRUCTIONS CAREFULLY BEFORE 

STARTING INSTALLATION.

•  Installation of the Lomanco 770D Roof Vent should 

comply with all local codes and standards.

•  WARNING! Sharp edges are exposed during 

installation. Use gloves and other appropriate safety 

equipment to avoid injury.

INSTALLATION:
1.  Vents should be evenly spaced on the rear slope of 

the roof. You also want to center vents on the roof 

length. (If you are installing two vents, locate each 

one 1/4 the distance from each end of roof. When 

installing three vents locate one in the center and 

the other two 1/6 the distance from each end of 

roof.)

2.  The seam of base should be centered on rafter 

centerline.  Locate rafter by tapping roof with 

hammer. Measure over 7-11/16" each side 

of rafter centerline.    Mark these positions. 

3.  Warm air rises; therefore, you want to locate roof 

vents as near as possible to the ridgeline.  Locate 

the vent holes roughly 24" (36" Max.) down from 

the ridgeline to keep the top of the roof vent 

below the ridgeline.  Mark this position. Vent 

location position should now be approximately 

24" down from ridgeline and centered over rafter.

4.  Using marked positions as center point scribe two 

9-1/2" diameter circles.   Drill a starter holes inside 

circles, a ½" drill bit should do this nicely.

5.  Starting in the drill holes cut two 9 1/2' diameter 

circular openings, using either a keyhole saw or 

an electric saber saw with sharp coarse blade. If 

you do not have a coarse blade, cut away shingles 

inside the circle with utility knife before cutting 

roof decking.  Take care not to make the holes too 

large or  water leakage may occur.

LOMANCO 770D ROOF VENT

INSTALLATION INSTRUCTIONS

Thank you for purchasing the LOMANCO 770D Roof Vent. The 770D is an 

exhaust vent that will help eliminate damaging heat and moisture from 

your attic when properly installed with intake vents.

"ITEMS NEEDED FOR INSTALLATION"

KEYHOLE SAW OR SABER SAW

UTILITY KNIFE

DRILL WITH ½" BIT

HAMMER AND ROOFING NAILS

TAPE MEASURE

ROOFING CEMENT

COMPASS OR STRING

 

24" APPROXIMATELY

(3'-0" MAX.)

9-1/2" DIA.

HOLE

 

PROPER SPACING 

TWO VENTILATORS

REAR VIEW

PROPER SPACING 

THREE VENTILATORS

REAR VIEW

CENTER

1/6

1/4

1/4

1/6

22300_1016