background image

Manual - Valiant 2

Pediatric

Pediatric

Lode BV
Zernikepark 16
NL 9747 AN
Groningen
The Netherlands
t: +31 50 571 28 11
f: +31 50 571 67 46
@: [email protected]
www.lode.nl

M938904_MANUAL VALIANT 2 PEDIATRIC / VERSION: V1.1 - 2016-08-25

Summary of Contents for 938904

Page 1: ...aliant 2 Pediatric Pediatric Lode BV Zernikepark 16 NL 9747 AN Groningen The Netherlands t 31 50 571 28 11 f 31 50 571 67 46 ask lode nl www lode nl M938904_MANUAL VALIANT 2 PEDIATRIC VERSION V1 1 201...

Page 2: ...s 5 Validity 6 Install your treadmill 7 Maintenance 7 1 Emergency stop installation 8 Troubleshooting 8 1 Belt alignment 9 Cleaning 10 Control with an External Device 11 Control with the Lode Ergometr...

Page 3: ...supervision of well trained medical specialists in the field of use The ultimate judgment whether a test subject should undertake a stress test with the device must be made by the responsible medical...

Page 4: ...ng while using the device Service of this device is restricted to factory trained personnel only Do not jump onto the rotating belt Do not jump off the rotating belt not even to the front Do not stop...

Page 5: ...t with protective earth to avoid the risk of electric shock The functional earth connection is for potential equalisation only The operator must keep away from the footrail while lowering The test sub...

Page 6: ...s No modification of this equipment is allowed Not suitable for use in the presence of flammable anaesthetics The appliance is not to be used by persons including children with reduced physical sensor...

Page 7: ...nt and or SpO2 blood saturation measurement These measurements may be inaccurate depending on use circumstances These measurements are indicative and cannot be used for diagnostic purposes 3 Contra In...

Page 8: ...ur treadmill 1 While unpacking the Lode treadmill ergometer leave the transport straps on both ends in place 2 Place the treadmill in the location where it will be used 3 Remove Both transport straps...

Page 9: ...maintenance Maintenance and all repairs should only be carried out by an authorized agency The manufacturer will not be held responsible for the results of maintenance or repairs by unauthorized pers...

Page 10: ...key on the left side Turning the key clockwise will make the belt move to the right side of the treadmill Turning the key counterclockwise will make the belt go left The red marked area shows where yo...

Page 11: ...he alignment procedure set the treadmill to maximum speed for 2 minutes and check the alignment of the belt Note NEVER use any lubricants on the walking belt The belt is self greasing using a wax laye...

Page 12: ...or the upholstery If you are not certain about the discolouring effect of a cleaning agent you may try a little on a part of the product that is not visible during normal use Lode cannot advise a spec...

Page 13: ...3 If your device has a control unit select Terminal mode to allow external command If your device does not have a control unit the terminal mode is automatically selected See for detailed instruction...

Page 14: ...or U S and Canadian markets FCC 18 RF ISM tested Symbol for collection treatment recycling and disposal of waste electrical and electronic equipment WEEE as set out in Directive 2002 96 EC of 27 Janua...

Page 15: ...15 21 M938904_MANUAL VALIANT 2 PEDIATRIC VERSION V1 1 2016 08 25...

Page 16: ...16 21 M938904_MANUAL VALIANT 2 PEDIATRIC VERSION V1 1 2016 08 25...

Page 17: ...13 Electromagnetic Compatibility EMC 17 21 M938904_MANUAL VALIANT 2 PEDIATRIC VERSION V1 1 2016 08 25...

Page 18: ...your treadmill may differ from the speed mentioned at the specifications 15 Accessories Colour display 3 5 single display Partnumber 945810 Clear feedback Colour display 3 5 single display Control Un...

Page 19: ...ric Handrails Side Adjustable for Valiant 2 Pediatric Partnumber 938802 Making your treadmill suitable for children Adjustable pediatric side handrails Handrail front singlesided Pediatric Valiant 2 P...

Page 20: ...B to Serial converter Partnumber 226012 Easy connection USB to Serial converter RS232 cable Partnumber 930911 Easy connection RS232 cable 20 21 M938904_MANUAL VALIANT 2 PEDIATRIC VERSION V1 1 2016 08...

Page 21: ...AC 50 60 Hz Maximum motor power 1 8 kW Standards Safety IEC 60601 1 2005 ISO 13485 2016 compliant ISO 9001 2015 compliant Standard emergency lanyard Certification CE class Im according to MDD93 42 EEC...

Reviews: