TARTING GOCATOR

 

NOTE: Gocator must be connected to a host computer in order to launch the user interface and set up the sensor.

Gocator sensors are configured by connecting with a web browser. For details on browser compatibility, see the user manual.

T

ROUBLESHOOTING

PROBLEM

SUGGESTED RESOLUTION

Mechanical / Environmental

The sensor is warm.

•  It is normal for a sensor to be warm when powered on. 

Connection

When connecting with a web 

browser, the sensor is not found 

(page does not load).

•  Verify the sensor power is on. This will be indicated by an illuminated POWER LED. 

•  Verify the Power & Ethernet cordset is connected to the Power/LAN connector and the Ethernet RJ45 plug is connected to the Ethernet switch.

•  Verify that the client computer’s network settings are properly configured. 

See 

Getting Started > Network Setup

 in the Gocator user manual or your computer’s documentation on configuring a network adapter.

•  Download 14405-x.x.x.x_SOFTWARE_GO_Tools.zip from the downloads area of LMI’s website at www.lmi3D.com.

Unzip and run the Sensor Discovery Tool [Discovery>kDiscovery.exe] to verify that the sensor has the correct network settings. 

When attempting to log in, the 

password is not accepted.

•  Download 14405-x.x.x.x_SOFTWARE_GO_Tools.zip from from the downloads area of LMI’s website at www.lmi3D.com. 

Unzip and run the Sensor Discovery Tool [Discovery>kDiscovery.exe] to find the sensor on the network and click Factory Restore.

 

WARNING: Performing a factory restore resets your configuration settings to their original values. These settings can be recovered from backup files if you 

have previously saved them.

Laser Profiling

When the Play button is pressed, 

the sensor does not emit laser light.

•  Ensure that the decal covering the laser emitter window, normally affixed to new sensors, has been removed.

•  Verify that the LASER LED on the Gocator is illuminated. If not, the laser safety input signal is off. 

To determine the correct solution for your application, see 

Specifications > Gocator Power/LAN Connector > Laser Safety Input

 in the user manual.

•  The exposure setting may be too low. For more information, see 

Gocator Web Interface > Scan Setup and Alignment > Sensor > Exposure

 in the user manual.  

The sensor emits laser light, but the  

Range Indicator does not illuminate 

and/or points are not displayed in 

the data viewer.

•  Verify that the measurement target is within the sensor’s field of view and measurement range.

The RANGE LED on the Gocator will illuminate when the target is in range. 

•  Check that the exposure time is set to a reasonable level. 

For more information, see 

Gocator Web Interface > Scan Setup and Alignment > Sensor > Exposure

 in the user manual. 

The sensor CPU level is near 100%.

•  Review the active measurements and remove any that are unnecessary.

•  Consider reducing the trigger speed.

•  Consider reducing the laser profiling resolution.

An example of the user interface in use

Quick Start Guide

For the user manual, CAD drawings, firmware release notes, SDK, 

and more, go to 

www.lmi3D.com

/support/downloads. 

15186-01.13_MANUAL_Quickstart_Gocator-1x00-Series-Side-Mount-Package

©2018 LMI T

echnologies Inc. All rights reserv

ed.

SIDE MOUNT PACKAGE

Americas  

LMI T echnologies (Head Offic

e)

  

Vanc

ouver

, Canada

  

+1 604 636 10

11

 

EMEAR  

LMI T echnologies GmbH

  Berlin, 

Germany

 

 

+49 (0)3328 9

360 0

Asia Pacific

 

LMI (Shanghai) Trading C

o., L

td. 

 

  Shanghai, 

China 

 

  +86 21 544

1 0711

LMI T echnologies has sales offic

es and distribut

ors 

worldwide

. All contact inf

ormation is lis

ted a

lmi3D.c

om/

contact/loca

tions

.

  

In Windows 7

a.  Open the Control Panel > Network and Sharing Center > Change 

Adapter Settings.

b. Right-click desired network connection, and then click 

Properties

.

c.  On the Networking tab, click 

Internet Protocol Version 4 (TCP/IPv4)

and then click 

Properties

.

d. Select “Use the following IP address” option.

e. Enter IP Address “192.168.1.5” and Subnet Mask “255.255.255.0”, then 

click 

OK

.

In Mac OS X 10.6

a.  Open the Network Pane in System Preferences and select 

Ethernet

.

b. Set 

Configure

 to “Manually”.

c.  Enter IP Address “192.168.1.5” and Subnet Mask “255.255.255.0”, and 

then click 

Apply

.

B. R

UNNING GOCATOR

 

A. L

AUNCHING THE INTERFACE

Open a web browser and enter the sensor address.

Step 2

Step 1

Gocator is shipped with the following default network  

configuration:

Setting

Default

DCHP

Disabled

IP Address

192.168.1.10

Subnet Mask

255.255.255.0

Gateway

0.0.0.0

Change network setting on host computer.

Step 1

Select the Manage page.

Step 2

Ensure that Replay mode is off (slider set to left) and that the 

Laser Safety switch is enabled or the Laser Safety input is 

high. Press the 

Start

 button in the toolbar to start the sensor 

(a laser line should now be visible).

Step 3

Move target into the laser plane and measure!

RECORD

SNAPSHOT

START

REPLAY (off)

Gocator sensors can also interface directly with HexSight. 

Refer to the HexSight Quick Start Guide for more information.

NOTE

The Gocator interface loads.