background image

IM3057 

02/2021 

REV04 

SPEEDTEC 215C 

 
 

OPERATOR’S MANUAL 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

ENGLISH 

 

Lincoln Electric Bester Sp. z o.o.

 

ul. Jana III Sobieskiego 19A, 58-260 Bielawa, Poland 

www.lincolnelectric.eu 

Summary of Contents for SPEEDTEC 215C

Page 1: ...IM3057 02 2021 REV04 SPEEDTEC 215C OPERATOR S MANUAL ENGLISH Lincoln Electric Bester Sp z o o ul Jana III Sobieskiego 19A 58 260 Bielawa Poland www lincolnelectric eu ...

Page 2: ...able below your equipment identification information Model Name Code Serial Number can be found on the machine rating plate Model Name Code Serial number Date Where Purchased ENGLISH INDEX Technical Specifications 1 ECO design information 2 Electromagnetic Compatibility EMC 4 Safety 5 Introduction 7 Installation and Operator Instructions 7 WEEE 17 Spare Parts 17 REACh 17 Authorized Service Shops L...

Page 3: ...1 Vdc 100 75A 17 7 Vdc 40 100A 19 Vdc FCAW SS 51 Vdc 100 75A 17 7 Vdc 40 100A 19 Vdc SMAW 51 Vdc 100 60A 22 4 Vdc 40 80A 23 2 Vdc GTAW 51 Vdc 100 90A 13 6 Vdc 40 125A 15 Vdc WELDING CURRENT RANGE GMAW FCAW SS SMAW GTAW 230Vac 20A 200A 20A 200A 20 160A 20A 160A 115Vac 20A 100A 20A 100A 20 80A 20A 125A RECOMMENDED INPUT CABLE AND FUSE SIZES Fuse or Circuit Breaker Size Power Lead B 16A B 25A 3 Condu...

Page 4: ...TIG mode STICK mode After 30 minutes of non working Fan off The value of efficiency and consumption in idle state have been measured by method and conditions defined in the product standard EN 60974 1 20XX Manufacturer s name product name code number product number serial number and date of production can be read from rating plate XXXXXXXXXX Code XXXXX XXXXXX X S N P1YYMMXXXXX 1 2 3 4 5 P1 YY MM X...

Page 5: ... process gas usage depends on cross sectional area of the nozzle For comonnly used torches Helium 14 24 l min Argon 7 16 l min Notice Excessive flow rates causes turbulence in the gas stream which may aspirate atmospheric contamination into the welding pool Notice A cross wind or draft moving can disrupt the shielding gas coverage in the interest of saving of protective gas use screen to block air...

Page 6: ...ocesses Equipment for calibration and measurement Personal medical devices like pacemakers and hearing aids Check the electromagnetic immunity for equipment operating in or near the work area The operator must be sure that all equipment in the area is compatible This may require additional protection measures The dimensions of the work area to consider will depend on the construction of the area a...

Page 7: ...l electrical regulations ELECTRICALLY POWERED EQUIPMENT Regularly inspect the input electrode and work clamp cables If any insulation damage exists replace the cable immediately Do not place the electrode holder directly on the welding table or any other surface in contact with the work clamp to avoid the risk of accidental arc ignition ELECTRIC AND MAGNETIC FIELDS MAY BE DANGEROUS Electric curren...

Page 8: ... work area CYLINDER MAY EXPLODE IF DAMAGED Use only compressed gas cylinders containing the correct shielding gas for the process used and properly operating regulators designed for the gas and pressure used Always keep cylinders in an upright position securely chained to a fixed support Do not move or transport gas cylinders with the protection cap removed Do not allow the electrode electrode hol...

Page 9: ...may adversely affect the operation of nearby radio controlled machinery which may result in injury or equipment damage Read the section on electromagnetic compatibility in this manual Do not operate in areas with an ambient temperature greater than 40 C Input Supply Connection WARNING Only a qualified electrician can connect the welding machine to the supply network Installation had to be made in ...

Page 10: ...d button for 4 seconds 9 Set Knob Type of welding procedure and welding settings is changed by this knob 10 Right Knob The value of parameter in the upper right side of display 2 is adjusted Figure 2 11 Gas Connector Connection for gas line 12 Power Lead with Plug 3m Power lead with plug is a standard equipment Connect the power lead with plug to the main supply before turning power on Figure 3 13...

Page 11: ...is information Take off the terminal block s shield 17 The tip of the wire on the terminal block 16 and work lead fix as is shown in the Table 1 or the Table 2 Put on the terminal block s shield WARNING The machine must be used with the door completely closed during welding WARNING Not use handle to move the machine during work Table 1 Positive polarity factory setting WORK LEAD ...

Page 12: ...English 10 English Table 2 Negative polarity WORK LEAD ...

Page 13: ...p again Adjusting of Force of Pressure Roll Force The pressure arm controls the amount of force the drive rolls exert on the wire Pressure force is adjusted by turning the adjustment nut clockwise to increase force counterclockwise to decrease force Proper adjustment of pressure arm gives the best welding performance WARNING If the roll pressure is too low the roll will slide on the wire If the ro...

Page 14: ...ng Depending on the welding process can be purchased separately see Accessories chapter Preparation the Machine for Welding GMAW and FCAW SS Process Procedure of begin welding of GMAW or FCAW SS process Determine the wire polarity for the wire to be used Consult the wire data for this information Connect output the gas cooled gun to GMAW FCAW SS process to Euro Socket 4 Depending on the using wire...

Page 15: ...ger is pulled again 4 step mode facilitates to making long welds WARNING 4 Step does not work during Spot Welding The Burnback Time is the amount of time that the weld output continues after the wire stops feeding It prevents the wire from sticking in the puddle and prepares the end of the wire for the next arc start Run in WFS sets the wire feed speed from the time the trigger is pulled until an ...

Page 16: ...witch off the output voltage on the output lead The welding current Switch on switch off the output voltage on the output lead Memory Save Recall Delete SPEEDTEC 215C enables saving recalling and deleting the parameter s settings 9 memories can be used by user Saving recalling and deleting process settings is accessible in advanced menu of SPEEDTEC 215C Error Messages Figure 6 This image above sho...

Page 17: ...nductance Select Gas Switch On Output Voltage TIG MMA only Spot Welding Setting Select Wire Type material Switch Off Output Voltage TIG MMA only Spot Timer Select Wire Size diameter Unlock panel Switch off Spot Welding Select Function of Gun Trigger 2 Step 4 Step Unlock Panel by Code 2 Step Configuration and Set up Hot Start 4 Step Lock Unlock Panel Arc Force Memory Lock Panel Adjust Voltage Save ...

Page 18: ... be disconnected from the machine before each maintenance and service After each repair perform proper tests to ensure safety Customer Assistance Policy The business of The Lincoln Electric Company is manufacturing and selling high quality welding equipment consumables and cutting equipment Our challenge is to meet the needs of our customers and to exceed their expectations On occasion purchasers ...

Page 19: ... First read the Part List reading instructions above then refer to the Spare Part manual supplied with the machine that contains a picture descriptive part number cross reference REACh 11 19 Communication in accordance with Article 33 1 of Regulation EC No 1907 2006 REACh Some parts inside this product contain Bisphenol A BPA EC 201 245 8 CAS 80 05 7 Cadmium EC 231 152 8 CAS 7440 43 9 Lead EC 231 ...

Page 20: ...English 18 English Quick Guide ...

Page 21: ...English 19 English ...

Page 22: ...English 20 English ...

Page 23: ...40 10A Contact Tip M6x25mm Al 1 0mm KP10468 Protection cap to FCAW SS process K10513 17 4V GTAW torch 4m E H 200A 25 3M Welding cable with electrode holder to SMAW process 3m K14010 1 Work Lead 3m KIT 200A 25 3M Lead s KIT to SMAW process The electrode holder with lead to SMAW process 3m Work lead 3m R 0010 450 1R Protective screen Drive rolls to 2 driven rolls Solid wires KP14016 0 8 V0 6 V0 8 KP...