FEATURES AND SPECIFICATIONS 

 

LEDS: 12 @ 3W (Tricolor RGB 3 in 1) 
Beam Angle:  25 º 
Control System: DMX-512 
DMX Channels:  3, 4, or 16  
DMX Connectors:  3 pin XLR 
Power: 100 - 250 VAC, 50/60 Hz  
Max Power Consumption: 50 Watts 
Body color: Black 
Size: 17.8"W x 12.3"D x 9.5"H  
Weight: 13 lbs 

 

DESCRIPTION 

 

The FXLD312R3I  is a RGB LED lighting fixture.  It 
is suitable for stage, disco, night club, and other artistic 
applications.  It has several stand alone control modes 
and can operate via a DMX-512 external signal. 

 

A double yoke enables the unit to be operated in 
several positions. 

 

INSTALLATION 

 

LOCATION 

 

The FXLD312R3I is rated IP20. The unit is intended 
for 

INDOOR USE ONLY.

 

 

Locate the unit in a well ventilated area away from 
moisture and heat.  Do not allow the vent or fan intake 
holes to be blocked.  Holes are provided on the  yokes 
to install a lighting bar pipe clamp. A safety cable 
should also be used.  

 
 
 
 
 
 
 
 
 
 

POWER CONNECTIONS 

 

The FXLD312R3I has dual (male and female) IEC 
type power connectors. The recessed male connector is 
for a line cable connection to a 120 VAC, 15 Amp, 
60Hz, grounded service.  This line cord is provided. 

 

The female IEC connector is to chain the power to 
another unit if multiple units are used together.  An 
IEC power cable for this purpose is also provided. 

 
 
 
 
 

 
 
 
 
 
 
 
 
 

 

DMX CONNECTIONS 

 

A system using DMX control should be connected as a 
chain of devices.  In other words the control signal 
cable should proceed from the controller to the first 
receiving device and then to others in a continuous 
"daisy chain" fashion. 

 

The fixture has a DMX IN and a DMX OUT connector 
to be used to connect the chain. The control cable 
should NOT be split into a multiple run star 
arrangement with a cable running from the controller 
directly to each receiving device pack. 

 

DMX CONNECTOR PIN ASSIGNMENTS 

 

There are two XLR connector types which can be used 
for DMX control.  Some units use 3 pin connectors. 
Others use 5 pin connectors. The FXLD312R3I 
receives a DMX signal on the 3 pin MALE connector 
on the back of the unit.  The 3 pin FEMALE connector 
is used to connect the next DMX device on the control 
chain.  If your console uses a 5 pin connector you can 
make an adapter cable to accommodate this. The table 
below shows the pin assignments for both the 3 pin and 
5 pin connectors. 

 
 
 
 
 
 
 

 

DMX TERMINATION 

 

A DMX chain should be terminated at the last 
receiving device on the chain.  This is done by 
installing a commonly available 1/4 Watt, 120 Ohm 

PIN # 

SIGNAL NAME 

1 DMX 

COMMON 

DMX DATA - 

DMX DATA + 

4 NOT 

USED 

5 NOT 

USED 

CHASSIS REAR VIEW 

FUSE

POWER

IN

OUT

DMX

INPUT OUTPUT

Summary of Contents for FXLD312R3I

Page 1: ...e cord is provided The female IEC connector is to chain the power to another unit if multiple units are used together An IEC power cable for this purpose is also provided DMX CONNECTIONS A system using DMX control should be connected as a chain of devices In other words the control signal cable should proceed from the controller to the first receiving device and then to others in a continuous dais...

Page 2: ...annel 4 channel or 16 channel unit This is controlled by the Mode Selection menu See the MENU NAVIGATION diagram in this manual DMX channel functions for the three modes are given in the table DMX CHANNEL ALLOCATIONS STAND ALONE OPERATION There are 6 stand alone operation options Flash All Fade Colors Run Program Sequence Colors Sound Sequence and Sound Flash FLASH ALL The Flash All mode flashes s...

Page 3: ... is externally accessible 5mm x 20mm fuse DISCONNECT THE UNIT FROM POWER BEFORE CHECKING OR REPLACING THE FUSE Replace the fuse ONLY with 2 0 Amp 250VAC fast blow fuse Internal service on the unit by other than Lightronics authorized agents will void the warranty If service is required contact the dealer from whom you purchased the item or contact the Lightronics Service Department 509 Central Dri...

Page 4: ...el All Lamps Blue Level All Lamps 4 Blue Level All Lamps Blue Level All Lamps Not Used 5 Red Level Lamp 1 Not Used Not Used 6 Green Level Lamp 1 Not Used Not Used 7 Blue Level Lamp 1 Not Used Not Used 8 Red Level Lamp 2 Not Used Not Used 9 Green Level Lamp 2 Not Used Not Used 10 Blue Level Lamp 2 Not Used Not Used 11 Red Level Lamp 3 Not Used Not Used 12 Green Level Lamp 3 Not Used Not Used 13 Blu...

Page 5: ...Page 5 of 6 FXLD312R3I LED LIGHTING FIXTURE Version 0 2 OWNERS MANUAL 03 30 2012 www lightronics com Lightronics Inc 509 Central Drive Virginia Beach Va 234354 757 486 3588 MENU NAVIGATION ...

Page 6: ...erves the right to make any changes modifications or updates as deemed appropriate by Lightronics to products returned for service Such changes may be made without prior notification to the user and without incurring any responsibility or liability for modifications or changes to equipment previously supplied Lightronics is not responsible for supplying new equipment in accordance with any earlier...

Reviews: