Страница 2: ...the system described herein is protected under US patent 4 935 346 Purchase of the system described herein does not act to grant a license under these patents Such a license is granted only when the...

Страница 3: ...ality Control Test 3 Performing a Patient Test 7 Blood Application 11 Color Chart 13 Transferring Data 14 Connection Module 14 Serial Cable 15 Cleaning 16 Cleaning the Outside of the Meter 16 Cleaning...

Страница 4: ...nce guide only after you have become familiar with the instructions and precautions outlined in the SureStepFlexx Meter Operator s Guide Test strip holder Power button LCD screen Optional barcode scan...

Страница 5: ...uccessful scan the infor mation appears in the display field Press to confirm the entry NOTE If the SCAN button does not appear a barcode scanner is not installed or enabled or battery power is too lo...

Страница 6: ...QC Test from the Main Menu 4 Select a control test 5 Enter your operator ID or scan your badge Press 6 Select the control solution lot number or scan the vial 7 Select the test strip lot number and co...

Страница 7: ...of solution to the center of the pink test square 9 Check the confirmation dot on the back of the test strip to verify it is completely blue 10 Firmly insert the test strip all the way into the test s...

Страница 8: ...ou fail to completely insert the test strip the test may start however you may receive an out of range result IMPORTANT If you insert the test strip after 2 minutes you may get an out of range result...

Страница 9: ...the control solution result fails repeat the test The system may not be functioning properly Do not use the system to test patient blood unless the control result falls within the expected range Pres...

Страница 10: ...n 3 Select Patient Test from the Main Menu 4 Enter your operator ID or scan your badge Press 5 Enter the patient ID or scan the ID tag Press 6 Select the test strip lot number and code or scan the bot...

Страница 11: ...8 7 Apply the patient s blood to the center of the pink test square 8 Check the confirmation dot on the back of the test strip to verify it is completely blue...

Страница 12: ...dot should be facing down Insert within 2 minutes of applying blood CAUTION If you fail to completely insert the test strip the test may start however you may receive an inaccurate low result CAUTION...

Страница 13: ...conds IMPORTANT Do not remove the test strip until the countdown is complete 10 Remove the test strip 11 Press and continue testing Or press Entr Note and choose one to three comments that correspond...

Страница 14: ...re you apply blood White pad absorbs excess blood that extends beyond the pink test square Confirmation dot is where you check for adequate blood application Apply a drop of blood to the center of the...

Страница 15: ...turated with blood you have applied too much blood for an accurate result Repeat the application using a new test strip If the blue confirmation dot on the back of the test strip shows streaks or patc...

Страница 16: ...e the test strip After a test you may check the meter result by comparing the confirmation dot to the Color Chart Do not use the Color Chart as a replacement for a meter result Unused Test for the mea...

Страница 17: ...y 2 Remove the meter from the cradle and press Cont if the meter is still on The meter turns off automatically after data transfer is complete To verify a successful upload check the status screen for...

Страница 18: ...n modem or serial server The meter automatically turns on and data transfer occurs 2 Remove the serial cable from the meter and press Cont if the meter is still on The meter turns off automatically af...

Страница 19: ...e residual bleach Dry thoroughly CAUTION Do not get water inside the meter Never immerse the meter or hold it under running water because it will damage the meter Cleaning the Test Strip Holder CAUTIO...

Страница 20: ...lder by pressing down on the left side and sliding it to the right 2 Wipe the test strip holder cover and base with a cotton swab dampened with a 10 bleach solution Follow with a swab dampened with wa...

Страница 21: ...ge or an inaccurate high result 3 Thoroughly dry the test strip holder with a soft cloth or lint free tissue 4 Wipe the lens area and contact points with a cotton swab dampened with a 10 bleach soluti...

Страница 22: ...to scratch this area 6 Replace the closed test strip holder by sliding it into the meter Push the test strip holder until it clicks into place 7 Turn on the meter If an error appears check to make su...

Страница 23: ...20 Changing the Batteries 1 Turn off the meter 2 Press down on the battery door latch Lift open the door 3 Remove all three batteries and dispose of them according to your institution s guidelines...

Страница 24: ...w size AA alkaline batteries Be sure to match the end of each battery with the signs inside the compartment CAUTION Donotuserechargeablebatteries 5 Replace the battery compartment door 6 Turn on the m...

Страница 25: ...en the meter does detect a problem it may not produce an error message every time the problem occurs In some situations improper use may cause an inaccurate result without producing an error message R...

Страница 26: ...eck that sample hematocrit is within range adult 25 60 neonatal 25 65 3 If you continue to get any error message obtain a laboratory result and Compare color of test strip confirmation dot to Color Ch...

Страница 27: ...ly1minbutnotmorethan2min afterapplyingsamplebeforeinsertingteststrip Do not alter test strips 2 If you continue to get any error message obtain a laboratory result and Compare color of test strip conf...

Страница 28: ...If glucose level is very high or very low take appropriate steps to monitor patient and provide medical care Repeat test with new test strip Do not move test strip after you insert it Remove test stri...

Страница 29: ...to meter Operating temperature is 18 30 C 2 If you continue to get any error message obtain a laboratory result and Compare color of test strip confirmation dot to Color Chart on test strip bottle to...

Страница 30: ...s very high or very low take appropriate steps to monitor patient and provide medical care Repeat test with new test strip Make sure test strip holder is fully inserted into meter Wait for Insert Stri...

Страница 31: ...t strip bottle If glucose level is very high or very low take appropriate steps to monitor patient and provide medical care Repeat test with new test strip Make sure test strip lot number and code ent...

Страница 32: ...en Insert Strip appears firmly insert test strip into test strip holder until it stops Cause Not enough sample on test strip or test strip inserted too quickly Solution Remove test strip Check confirm...

Страница 33: ...stem administrator to enable meter s barcode scanner 2 Check meter s battery bar for adequate power Change meter batteries if necessary 3 If meter is not equipped with barcode scanner manually enter i...

Страница 34: ...nserted or dirty test strip partially inserted or lens area dirty Solution 1 Check test strip holder is properly installed 2 Remove test strip from meter 3 Clean test strip holder and lens area Cause...