background image

P/ No.: 3828EL2002C

Summary of Contents for TD-V10115E

Page 1: ...P No 3828EL2002C ...

Page 2: ...el and Serial Numbers and retain the manual for future reference If you use GAS dryer this dryer is equipped for use with NATURAL GAS DO NOT connect the dryer to the Liquefied Petroleum LP Gas service without converting the gas value A qualified technician must perform the LP Gas conversion Owner s Manual Electric and Gas Dryer TD V10115E TD V10115G ...

Page 3: ...TRIC DRYER 15 16 PART5 ELECTRICAL REQUIREMENTS FOR GAS DRYERS 17 18 PART6 GAS REQUIREMENTS AND INSTRUCTIONS 19 PART7 EXHAUST REQUIREMENTS AND MAINTENANCE 20 21 PART8 OPERATING YOUR DRYER 22 27 PART9 TROUBLESHOOTING GUIDE 28 30 What are Sensor Dry and Time Dry Your dryer provides sensor drying and time drying programs Sensor Dry Dryer senses electronically laundry humidity and it automatically dete...

Page 4: ...er to the rating label regarding detailed information Size 27 68 6 cm x 29 73 7 cm x 43 7 111cm inch Capacity IEC 7 3 cu ft 10 0kg Weight 126 Ibs 57 2 kg Specifications are subject to change by manufacturer ACCESSORIES Dryer rack 1 each See page 25 for how to use ...

Page 5: ...commendations in this manual must be followed To reduce the risk of fire or explosion electric shock or to prevent property damage personal injury or death when using your appliance follow basic precautions including the following WARNING Warranty Restriction If the dryer is subjected to other than private family use all warranty coverage is effective for only 90 days You will need the complete Mo...

Page 6: ...s may contribute to a chemical reaction that could cause a load to catch fire 14 Do not use fabric softners or products to eliminate static unless recommended by the manufacturer of the fabric softner or product GROUNDING INSTRUCTIONS This appliance must be grounded In the event of malfunction or breakdown grounding will reduce the risk of electric shock by providing a path of least resistance for...

Page 7: ... have ever had any kind of oil on them including cooking oil Articles containing foam rubber rubber like materials plastic or similar materials should be dried on a clothesline or by using an air cycle Failure to follow these instructions can result in fire death or serious injury A qualified service person or company must perform installation and service of this appliance This act requires the go...

Page 8: ... that fabrics that contain vegetable or cooking oil or have been contaminated by hair care products be placed in a tumble dryer they should first be washed in hot water with extra detergent this will reduce but not eliminate the hazard The cool down cycle of tumble dryers should be used to reduce the temperature of the items They should not be removed from the tumble dryer or piled or stacked whil...

Page 9: ...arance behind the dryer for the exhaust vent with elbow Positioning the Dryer STEP 1 29 73 7cm 43 7 111 cm 27 68 6cm 51 129 5cm Ventilation hole Ventilation hole Certain minimum clearances are required above behind and to the sides of the unit as shown below Those required minimum clearances are set forth in the picture below Please also keep the following instructions in mind when installing in a...

Page 10: ...llation The door on your dryer can be installed to open either to the left or the right Follow these procedures to reverse the direction in which your door opens Open the door and remove the filler plugs opposite the hinges Procedure for Reversing the Door STEP 2 Note Door and latch should be aligned at the center when closed Otherwise door is improperly closed and opened REMOVE FILLER PLUGS 1 REM...

Page 11: ...door catch and filler plate Install them on opposite sides of the door Insert the door on the opposite side of the open ing by moving the door IN and DOWN until the top hinge and the bottom hinge are resting on the top screws inserted in Step 2 Tighten the two top screws of each hinge Reinsert the plastic plugs on the side from which the door was removed Remove the remaining screws from the side o...

Page 12: ...ale end of each section of exhaust duct must point away from the dryer Use as few elbow joints as possible Use duct tape on all duct joints Insulate ductwork that runs through unheated areas in order to reduce condensation and lint build up on pipe walls and PLEASE BE AWARE THAT FAILURE TO EXHAUST THE DRYER CORRECTLY WILL VOID THE DRYER S WARRANTY 2 1 Detach and remove the knockout that matches th...

Page 13: ...r and your laundry room s gas supply Turn on your laundry room s gas supply and check all pipe connections both internal and external for gas leaks with a non corrosive leak detection fluid Refer to Part 7 page 20 5 For LP Liquefied Petroleum gas connection refer to this manual s section entitled Gas Requirements and Instructions 1 New stainless steel flexible connector Use this type of connector ...

Page 14: ...ssure MAXIMUM STATIC PRESSURE IN WATER COLUMN 0 6 inches 1 5 cm Confirming Heat Source in Gas Dryers Close the door to the dryer drum drying compartment and after completing all steps in this manual for proper installation of this dryer start the dryer on a heat setting as described more fully in the operating instructions that accompany the dryer After the dryer starts the igniter will glow red a...

Page 15: ...e vented to the outside using the back left right or bottom panel 5 Gas dryers may be vented to the outside using the back left or bottom panel Gas dryer may not be vented to the outside using the right side panel because of the burner housing 6 The dryer exhaust duct must be affixed securely to the manufactured or mobile home structure and the exhaust duct must be made of a material that will res...

Page 16: ...T d If branch circuit to dryer is fifteen feet 4 50 m or less in length use U L Underwriters Laboratories listed No 10 A W G wire copper wire only or as required by local codes If over fifteen feet 4 50 m use U L Underwriters Laboratories listed No 8 A W G wire copper wire only or as required by local codes Allow sufficient slack in wiring so dryer can be moved from its normal location when necess...

Page 17: ...crew is tightened and be sure that all terminal block nuts are on tight and power cord is in right position 4 Connect a independent ground wire from external ground connector to proper ground Live wire black Neutral wire white External ground connector Separate ground wire The dryer power connection of the dryer has 2 types which defer based on power consumption If power cord has no plug it has to...

Page 18: ...ns please have a qualified service person or company for example a qualified electrician or your local electric company review your laundry room s electrical supply for any problems 120 127Volt 60 Hertz with 3 Prong Grounding Plug Following are additional instructions regarding electrical connections and requirements for gas dryers Important Warning To help prevent fire electric shock serious inju...

Page 19: ... appliances recommend they be placed upon a dedicated circuit that is a single outlet circuit which powers only that appliance and has no additional outlets or branch circuits Check the spercification page of this owner s manual to be certain Do not overload wall outlets Overloaded wall outlets loose or damaged wall outlets extension cords frayed power cords or damaged or cracked wire insulation a...

Page 20: ...cceptable under local codes and ordinances and when acceptable to your gas supplier 3 8 inch approved tubing may be used where lengths are less than 20 feet 6 1m Larger tubing should be used for lengths in excess of 20 feet 6 1m It is also important that you use pipe joint compound that is insoluble in LP gas 6 To reduce the danger of gas leaks explosion and fire please follow and observe the foll...

Page 21: ...ocally For example the outer end of exhaust pipe must have a weather hood with hinged dampers to prevent back draft when the dryer is not in use 2 The exhaust duct must be four inches 10 2 cm in diameter with no obstructions The exhaust duct should be kept as short as possible Make sure to clean any old ducts before installing your new dryer 3 Rigid metal duct is recommended Do not install flexibl...

Page 22: ...ilter and attach it to the vacuum duct See item 2 above 12 Please note that the wiring diagram is provided inside the dryer control hood Label all wires prior to disconnection when servicing the dryer because wiring errors can cause serious injury to you and your dryer 1 Clean the lint filter either before drying each load or after drying each load Always make sure the lint filter is clean before ...

Page 23: ...ycle Failure to follow these instructions can result in death or fire Fire Hazard Use this button for power on or off Following are instructions for starting and using your new dryer Please refer to specific sections of this manual for more detailed information Important Warning To reduce the risk of fire electric shock or injury to person read this entire manual including the Important Safety Ins...

Page 24: ...es corduroys PERMPRESS Synthetics permanent press ULTRA DELICATE Shear workout wear and lace items DELICATE Lingerie sheets blouses 1 Sensor Dry Cycles 2 Manual Dry Cycles Use Manual Cycles to select a specific amount of drying time and a drying temperature When a Manual Cycle is selected the ESTIMATED TIME REMAINING display shows the actual time remaining in your cycle You can change the actual t...

Page 25: ... CUSTOM PROGRAM To recall your stored CUSTOM PROGRAM Press CUSTOM PROGRAM button then press START PAUSE Child Lock 6 Child Lock can be used to prevent your children from undesirable use on control panel while the dryer is running When Child Lock is enabled all the button will be locked and Child Lock glows To lock Child Press and hold Dry Lavel and Temp Control for 3 seconds A single beep tone is ...

Page 26: ...theAir Dry Temperature setting Refer to the following table Start the dryer Note Check the lint screen and remove any lint accumulated from items dried on the rack 1 Open the door Hold the dryer rack with both hands To use the RACK DRY 2 Put the dryer rack into the drum 3 Make sure Dryer RACK is evenly spaced right onto the drum inside and door rim Suggested Items for Rack Drying Washable wool ite...

Page 27: ...r Sensor Dry Cycles or Manual Cycles will glow The estimated or actual cycle time in minutes will show in the display OPERATING YOUR DRYER Part 8 Following are sample loads for Super Capacity Dryers Heavy Work Clothes 4 jeans 4 workpants 4 work shirts Mixed Load 3sheets 1king 2twin 4pillowcases 3shirts 3blouses Cotton Towels 10 bath towels 10 hand towels 2 sweatpants 2 sweatshirts 14 wash cloths 9...

Page 28: ...ter using one of following ways in cases Run the fingers across the filter Vacuum the lint filter Wash the lint screen in warm soapy water Dry thoroughly and replace Maintenance Note Drying will continue from where the cycle was interrupted if you close the door and press START within 10 minutes If the cycle is interrupted for more than 10 minutes the dryer will shut off Select new cycle settings ...

Page 29: ...se box circuit breaker box and replace the fuse or reset the circuit breaker IMPORTANT electric dryers generally use two fuses or breakers Confirm that the house gas shutoff and the dryer gas shutoff are both fully open Is the gas supply or service blocked or off What to Do 2 Problem My Dryer Doesn t Heat Question Did you follow the instructions on your fabric softener product Confirm and follow t...

Page 30: ...ly sort your load of laundry Do your clothes have excess static electricity Did you overload your dryer Did you place any paper tissue or other similar material in the load What to Do 4 Problem There is Lint on my Clothes Question Did you use fabric softener Try using a fabric softener to reduce static electricity Over drying a load of laundry can cause a build up of static electricity Try using a...

Page 31: ... smaller loads If you are only drying a handful of items add a few extra pieces to help ensure proper tumbling action Are you drying large loads of heavy fabrics Are the dryer controls properly set Is the lint filter clean before each new load of laundry Are the exhaust ducts clear and properly configured Is the fuse blown or is the circuit breaker tripped Did you overload your dryer Did you under...

Page 32: ......

Reviews: