background image

CDMA Fixed Wireless Terminal

Owner’ s Manual

Model:  LST-200 & 2200

Summary of Contents for LST-200

Page 1: ...CDMA Fixed Wireless Terminal Owner s Manual Model LST 200 2200 ...

Page 2: ...N 1999 01 ISSUE 1 Initial release Please read this manual before you use this product This manual is based on the production version of LST 200 2200 FWT Software changes may have occurred after this printing LGIC reserves the right to make changes in technical and product specifications without prior notice ...

Page 3: ... 13 Power On 13 Placing a call 13 Receiving a call 13 Ending a call 13 Dial Tone after Remote Disconnect 13 Dial Delay 13 Emergency Call 14 4 System Features 15 Hookflash 15 Dial Time 15 ROH Receiver Off Hook 15 Special Cellular Services 15 Applications 16 5 Programming 17 Speed Dial 17 Storing the Speed Dial Number 17 Enable or Disable Speed Dial 17 Operation 18 Emergency Call 18 Entering the eme...

Page 4: ... hour Mode 19 Disable Alarm Feature 19 Volume Level 20 Changing the Volume Level 20 Outgoing Call Lock 20 Enable or Disable Outgoing Call Lock 20 Changing Outgoing LOCK Code 20 G3 FAX Receive Mode 21 Enable or Disable G3 FAX Receive mode 21 6 Troubleshooting 22 7 General Information 23 LST 200 23 LST 2200 24 ...

Page 5: ... hospital monitor Consult the manufacturer of any personal medical devices to determine if they are adequately shielded from external RF energy Turn your terminal OFF in health care facilities when any regulations posted in the areas instruct you to do so Hospitals or health care facilities may be using equipment that could be sensitive to external RF energy l If this equipment does cause harmful ...

Page 6: ... Telephone from the wall outlet and remove antenna or disconnect antenna cable before cleaning Do not use liquid or aerosol cleaners Use a damp cloth for cleaning l If the unit fails for any reason do not attempt to disassemble contact the telephone service provider for assistance l If any of the following conditions exist Unplug the unit at the wall plug remove battery and call the service provid...

Page 7: ...r Pulse Dialing l Support Caller ID Telephone l Voice Mail Notification ring alerts you to new voice mail messages l ROH Receiver off hook tone which is the sound you hear when a telephone handset is left off hook for an extended period of time with no activity l Ring voltage used to ring the telephone connected to the unit with a Ringer Equivalence Number of 4 l A phone jack to plug in the teleph...

Page 8: ...AX PHONE RS 232C DC12V LG 2 6 5 4 3 Figure 1 ITEM DESCRIPTION çLEDs Indicate the status of the unit èDC 12V AC Power Adapter éRS 232C DB 9 Connector Connecting Port for Data Service to PC êFAX RJ 11 Jack Connecting Port for G3 FAX Machine ëPhone RJ 11 Jack Connecting Port for Single Line Telephone ìTNC Antenna Connector ...

Page 9: ...Power is applied YELLOW solid Battery Power is applied POWER LED RED solid Low Battery GREEN solid Good Signal YELLOW solid Poor Signal SIGNAL LED RED solid No Service Area GREEN blink 0 5sec On 0 5sec Off Voice Message is received GREEN blink 1 sec On 1 sec Off Data Service is working MODE LED RED blink G3 Fax option is connected ...

Page 10: ...tenna up right l Connect your phone cord to the RJ 11C port located at the left side of the terminal l Connect the AC power supply cable to the DC input port located at the right side of the terminal l If you use Data Service or PC FAX Service connect your RS 232C cable cord to the DB9 port located at the right side of the terminal l If you use G3 FAX machine connect your line cord of G3 FAX to th...

Page 11: ...g upon 8 Insert the terminal into the bracket until you hear two snaps both sides of the unit should snap into the bracket 9 Insert the DC power pack into an electrical outlet and attach the telephone line into the Phone Jack RJ 11 of the unit Note Some wall materials may require special inserts of plugs to secure a screw and support the bracket POWER MODE SIGNAL TNC Antenna Connector FAX PHONE RS...

Page 12: ...ok the terminal determines whether cellular service is available If it is available dial tone is produced and a number can be dialed normally If phone service is not available LED 2 of the terminal Signal LED will be red and no dial tone will be heard Receiving a call The connected telephone rings when an incoming call is detected Pick up the handset and begin talking Ending a call When you have c...

Page 13: ...en caller hangs up the phone the line will be still connected so if the caller picks up the phone again he can continue talking If emergency call is connected cellular service is not supported As long as your telephone is registered on a system you can place a call to emergency number including 911 even if your telephone is locked or restricted Please check the available emergency call number with...

Page 14: ...r systems offer special services such as call waiting call forwarding etc You can purchase these services from your cellular service provider There are certain dialing sequences to be entered which vary from service provider to service provider The service provider will provide the dialing instructions for your system Call Forwarding An incoming call can be delivered to another telephone number pr...

Page 15: ...ications Data Communication LST 200 2200 is capable of transmitting and receiving IS 99 Fax or modem communications For data communications you will need a data communication kit and a diskette where needed For further information please contact our authorized service dealer Multi extension Installations For a multi extension installation make sure that all the extensions are on hook If one extens...

Page 16: ...ey and you will hear confirmation tone 4 Enter sub fields and their options 5 Press key to save and you will hear confirmation tone Speed Dial LST 200 2200 has 30 memory locations 1 30 1 or 2 digits to store frequently used phone numbers and you can make a call by pressing memory location number only when the speed dial feature is enabled Storing the Speed Dial Number 1 Press 1 continuously to ent...

Page 17: ...continuously to enter emergency call programming mode 2 Press and Enable code 1 or Disable code 2 3 Press to save If Emergency Call is disabled and Emergency Call number has been already programmed you can make enable Emergency Call by pressing 2 1 without entering a emergency call number again Hot Line While the Hot line function is enabled the programmed number will be automatically dialed when ...

Page 18: ...larm If alarm feature is enabled you will hear ring at the programmed alarm time every day for 1 minute Entering Alarm Time 12 hour Mode 1 Press 4 continuously to enter alarm time programming mode 2 Press and alarm time code 1 for 12 hour mode 3 Press and alarm time HHMM am 1 pm 2 4 In the forenoon time range is 0000 1159 5 In the afternoon time range is 1200 1259 or 0100 1159 6 Press to save and ...

Page 19: ...ng Call Lock If you try to make an outgoing call while outgoing call lock is enabled then you will hear warning tone after pressing or dial time out as a indication of entering the LOCK code You should enter LOCK code to make an outgoing call LOCK code is composed of 4 digits and the initial setting is 0000 Outgoing Call Lock feature is disabled as a factory setting Enable or Disable Outgoing Call...

Page 20: ... you can make an outgoing call from your single line telephone and make a FAX outgoing call from G3 FAX But receiving call is ringing to G3 FAX machine even if the caller is not FAX because the terminal doesn t recognize the call is for FAX or voice Following is the procedure to change data path and default data path is RS 232C data path Enable or Disable G3 FAX Receive mode 1 Press 7 continuously...

Page 21: ... data transmission Contact your service provider if either of the following condition is true l The terminal does not work and the LED indicates No Service and if changing the locations does not resolve the problem l The terminal does not work and the LED indicates In Service l Power Supply If the unit does not respond once plugged into a power supply Check that the AC power source Check that the ...

Page 22: ...gital 150 Hz Tx Power Digital Max 0 2W Rx Power Level 104 25 dBm Size 190 X 190 X 46 L X W X H Weight g Below 860 without battery AC DC Adapter Item Description Input Voltage 110 220V AC Option Input Current 2A Input Frequency 45 60 Hz Output Voltage 12V DC Battery Item Description Capacity 7 4V NiMH 2500mAH Talk duration time 1 Hours Standby duration time 24 Hours Charging duration time Trickle 2...

Reviews: