background image

Monocrystalline Solar Module 

LGXXXS1C(W, K)-G3 

Summary of Contents for LG S1C-G3 Series

Page 1: ...Monocrystalline Solar Module LGXXXS1C W K G3 ...

Page 2: ...1 Revisions Table Date Version Amendments Tech note 2012 08 01 1 0 1st edition Establish 2012 11 16 2 0 2nd edition Legality check ...

Page 3: ...e frame or glass of the module may decrease the strength of the frame or break the glass Do not touch the glass surface or frame of the solar module after installation of the module It may result in injury or death Heavy objects must be kept off of the solar module Do not stand on or step on the module Do not drop the module Failure to comply may result in product damage product failure or bodily ...

Page 4: ...ations are made at conditions of 1000W m2 irradiance and 25 C 77ºF solar cell temperature Colder temperatures may substantially increase voltage and power Keep the solar module and system away from children at all times Keep the module packed in the carton until the time of installation Keep flammable gasses away from the installation site Do not work alone Work as part of a team of two or more pe...

Page 5: ...d in series should be the same The maximum number of series connected modules can be determined by max system voltage the 125 safety factor not explained in specifications and the module Voc which can be checked in Product Specifications in this document Do not exceed 80 of maximum system voltage Maximum Module configuration recommend refer to the Product Specification in this manual Parallel Conn...

Page 6: ...e spring washer two flat washers one cup washer one star washer and 12 AWG Cu wires are recommended per mounting hole Where common grounding hardware nut bolts washers is used to attach a listed grounding device the attachment must be made in conformance with the grounding device manufacturer s instructions There is an earth hole on the edge of the module frame Using this hole an earth conductor a...

Page 7: ... of 100mm When installed on a roof the solar module must be mounted over a fire resistant roof covering rated for the application The fire resistance of the solar module is class C after ANSI UL790 The solar module is only IEC listed for use when its factory frame is fully intact Removal or alteration must be done by an authorized and qualified individual Creating additional mounting holes may dam...

Page 8: ...to the rooftop 2 Flat roof If installed with an additional stand such as wind shield or deflector Use four clamps on the long frame Use four mounting holes on two opposite sides Mounting Type Clamping Type Long Side Clamping Type Short Side LGXXXS1C W K G3 Clamping Range 230mm 270mm 270mm 7 Clamping Range From module Edge to 120mm Clamping Range From module Edge to 270mm Center 100mm Center 100mm ...

Page 9: ... 600 12 MC4 1640 1000 35 16 8 15 LG250S1C G3 Yes 250 3 38 26 8 62 30 77 8 13 46 0 2 0 420 4 5 600 12 MC4 1640 1000 35 16 8 15 LG255S1C G3 Yes 255 3 38 41 8 72 30 97 8 24 46 0 2 0 420 4 5 600 12 MC4 1640 1000 35 16 8 15 LG260S1C G3 Yes 260 3 38 56 8 82 31 17 8 35 46 0 2 0 420 4 5 600 12 MC4 1640 1000 35 16 8 15 LG265S1C G3 Yes 265 3 38 71 8 92 31 37 8 46 46 0 2 0 420 4 5 600 12 MC4 1640 1000 35 16 ...

Page 10: ... connected to installation operation or service of LG Solar Modules and if applicable from all liabilities claims demands losses or damages on my account caused or alleged to be caused in whole or in part by the negligence of the LG its affiliated companies successors or assigns its administrators directors agents officers volunteer and employees Disposal Please contact us if you have any queries ...

Page 11: ...om http www lgsolarusa com This document is subject to change without notice LG LG logo and Life s Good are trademarks of LG Electronics Inc worldwide Trademarks and intellectual properties of LG Electronics Inc are protected by international copyright laws Document II G3 UL V2 EN 201211 10 ...

Reviews: