background image

WARNINGS AND CAUTIONS

:

•  To be installed and/or used in accordance with appropriate electrical codes and regulations.

•  If you are unsure about any part of these instructions, consult a qualified electrician.

•  Vizia™ RF electronic switches are not compatible with standard 3-way or 4-way switches. They must be used with compatible Vizia™ or Vizia™ RF controllers.

•  Recommended minimum wall box depth is 2-1/2".

WARNINGS AND CAUTIONS

:

•   Use only one (1) Vizia

TM 

 RF electronic switch in a multi-location circuit with up to 9 Vizia

TM

 coordinating remotes without LEDs or Vizia

TM

 RF remotes for multi-location.

•  Maximum wire length from dimmer to all installed remotes cannot exceed 300 ft (90 m).

•  Disconnect power at circuit breaker or fuse when servicing, installing or removing fixture.

•  Use this device only with copper or copper clad wire. With aluminum wire use only devices marked CO/ALR or CU/AL.

Single Pole (One location) or 3-Way (Multi-location)

Scene Capable Electronic Switch

Cat. No. RZS15-1L, (Lighted)

Incandescent-1800W – Magnetic Low-Voltage-1800VA (1440W)

Electronic Low-Voltage-1800W – Fluorescent-1800VA – Supplemental-1/2 HP

120VAC, 60Hz

INSTAllATION INSTRUCTIONS

DI-000-RZS15-00C

 Tools needed to install your Switch

Slotted/Phillips Screwdriver 

Electrical Tape 

Pliers 

 

Pencil 

 

 

Cutters 

 

Ruler

line up tabs 

and press in 

side to attach

Push in 

side at tab 

to release

Changing the color of your Switch:

Your switch includes three color options. The switch ships with the White 

frame attached. To change color of frame, proceed as follows:

INSTAllING YOUR SWITCH

NOTE:

 Use check boxes           when Steps are completed.

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

/.

/&&

WARNING: 

TO AVOID FIRE SHOCK OR DEATH; TURN 

OFF POWER 

at circuit breaker or fuse and test that power is off 

before wiring!

 

Step 1

2

4

3

1

Single Pole
1.

  Line (Hot)

2.

  Neutral

3.

  Ground

4.

  Load 

2

4

1

5

3

3-Way
1.

  Line or Load 

(see 

important instruction)

2.

  Neutral

3.

  Ground

4.

  First Traveler – note color

5.

  Second Traveler – note 

color

Identifying your wiring application (most common):

NOTE:

 If the wiring in your wall box does not resemble any of 

these configurations, consult a qualified electrician.

 

Step 2

Compatible with

enabled products!

TM

IMPORTANT :

 For 3-Way applications, note that one of the screw terminals 

from the old switch being removed will usually be a different color (Black) 

or labeled Common. Tag that wire with electrical tape and identify as the 

common (Line or Load) in both the switch wall box and remote wall box.

BK

WH

Yl/RD RD

Terminal

Screw marked

Black (BK)

Terminal

Screw marked

Red (RD)

Terminal

Screw marked

Yellow/Red

(Yl/RD)

Terminal label:

Use Terminal for 3-Way or More Applications Only.

For Single-Pole Applications, Do Not Remove This

label.

4

3

2

Terminal

Screw marked

White (WH)

1

Single Pole Wiring Application:

 

Step 4a

 

Step 3

Preparing and connecting wires:

This switch can be wired using side wire terminal screws or 

through backwire openings. Choose appropriate wire stripping 

specifications accordingly.

•  Make sure that the ends of the wires from the wall box are 

straight (cut if necessary).

•  Remove insulation from each wire in the wall box as shown.

•  For Single-Pole Application, go to Step 4a.
•  For 3-Way Coordinating Remote (no lEDs) Application, go to Step 4b.

5/8" 

(1.6 cm)

Strip Gage 

(measure bare 

wire here)

Cut 

(if necessary)

Side Wire Connection 

Side wire terminals accept #14 

AWG 

solid wire copper only

.

Back Wire (either hole may be used) 

Back wire openings use #14-12 AWG 

solid wire copper only

Hot (Black)

Neutral (White)

Load

Switch

BK

WH

Black

White

RD

Green

Ground

YL/RD

Line 

120VAC, 60Hz

Use Terminal for 3-Way or

More Applications Only.

For Single-Pole Applications,

Do Not Remove This Label.

WIRING SWITCH:

Connect wires per WIRING DIAGRAM as follows:

•  Green or bare copper wire in wall box to Green terminal screw.

•  Line Hot wall box wire to terminal screw marked "BK".

•  Load wall box wire to terminal screw marked "RD".

•  Line Neutral wall box wire to terminal screw marked "WH".

•  Switch terminal screw marked "YL/RD" should have Red insulation 

label affixed. 

 

NOTE:

 If insulating label is not affixed to terminal screw marked "YL/RD", 

use electrical tape to cover.

• 

Proceed to Step 5.

BK

WH

Yl/RD RD

Coordinating Remote

Switch

5

2

1

4

3

BK

WH

Yl/RD RD

4

3

1

5

Terminal

Screw marked

Red (RD)

Terminal

Screw marked

White (WH)

2

Terminal

Screw marked

Black (BK)

Terminal

Screw marked

Yellow/Red

(Yl/RD)

3-Way Wiring with Coordinating Remote 

(no lED) Application:

 

Step 4b

Hot (Black)

Neutral (White)

Coordinating Remote (no LED)

YL/RD

YL/RD

RD

WH

RD

BK

Black

BK

WH

White

Line 

120VAC, 60Hz

Green

Ground

Green

Ground

(unused)

(unused)

Load

Switch

WIRING SWITCH:

Connect wires per WIRING DIAGRAM as follows:

NOTE:

 The switch must be installed in a wall box that has a Line Hot 

connection.

NOTE:

 Maximum wire length from switch to all installed remotes cannot 

exceed 300 ft (90 m).

•  Green or bare copper wire in wall box to Green terminal screw.

•  Line Hot (common) wall box wire identified (tagged) when removing 

old switch

  to terminal screw marked "BK".

•  First Traveler wall box wire to terminal screw marked "RD" 

(note wire color)

.

•  Remove Red insulating label from terminal screw marked "YL/RD".

•  Second Traveler wall box wire to terminal screw marked "YL/RD"  

(note wire color)

. This traveler from the switch must go to the 

terminal screw on the remote marked "YL/RD".

•  Line Neutral wall box wire to terminal screw marked "WH".

Leviton’s Vizia™ RF Z-Wave™ components are designed to communicate 

with each other via Radio Frequency (RF) to provide remote control of 

your lighting. Using RF technology allows Leviton to provide the greatest 

signal integrity possible. Each module in Leviton’s Vizia™ RF component 

line is a Z-Wave™ enabled device. In a Z-Wave™ network, each device 

is designed to act as a router. These routers will re-transmit the RF signal 

from one device to another until the intended device is reached. This 

ensures that the signal is received by its intended device by routing the 

signal around obstacles and radio dead spots. The Scene Capable Plug-In 

Appliance Module is compatible with any Z-Wave™ enabled network, 

regardless of the manufacturer and can also be used with other devices 

displaying the Z-Wave™ logo.

 

CAUTION:

Remember to exercise good common sense when using the Timer 

features of your Remote – especially when scheduling unattended devices. 

There can be some unexpected consequences if not used with care. For 

example, an empty coffee pot can be remotely turned on. If that should 

happen, your coffee pot could be damaged from overheating. If an electric 

heater is turned on by remote control while clothing is draped over it, a 

fire could result. 

DO NOT USE

 the remote for the control of high power 

heating appliances such as portable heaters. This device will not control 

lighting that is used with electronic low-voltage and high frequency power 

supply transformers, nor high pressure discharge lamps (HID lighting). 

This includes mercury-vapor, sodium vapor and metal halide lamps.

•  Switch ON/OFF 

•  Scene Capable

•  ON/OFF LED

•  Two way communication 

•  RF reliability

•  Ease of installation – No new wiring

•  Compatible with other Z-Wave™ enabled devices

 FEATURES

 INTRODUCTION

Reviews: