background image

© 2015 Leviton Mfg. Co., Inc.

For Technical Assistance Call: 1-800-824-3005 (U.S.A. Only) www.leviton.com

LIMITED 2 YEAR WARRANTY AND EXCLUSIONS

Leviton warrants to the original consumer purchaser and not for the benefit of anyone else that this product at the time of its sale by Leviton is free of defects in materials and workmanship 

under normal and proper use for two years from the purchase date. Leviton’s only obligation is to correct such defects by repair or replacement, at its option. 

For details visit www.

leviton.com or call 1-800-824-3005.

 This warranty excludes and there is disclaimed liability for labor for removal of this product or reinstallation. This warranty is void if this product is 

installed improperly or in an improper environment, overloaded, misused, opened, abused, or altered in any manner, or is not used under normal operating conditions or not in accordance 

with any labels or instructions. 

There are no other or implied warranties of any kind, including merchantability and fitness for a particular purpose

, but if any implied warranty 

is required by the applicable jurisdiction, the duration of any such implied warranty, including merchantability and fitness for a particular purpose, is limited to two years. 

Leviton is 

not liable for incidental, indirect, special, or consequential damages, including without limitation, damage to, or loss of use of, any equipment, lost sales or profits or 

delay or failure to perform this warranty obligation

. The remedies provided herein are the exclusive remedies under this warranty, whether based on contract, tort or otherwise.

15 and 16 Series Snap-Back Cover

Cat. Nos. 15S31, 16S31

WARNINGS AND CAUTIONS

 

TO AVOID FIRE, SHOCK OR DEATH,

 

TURN OFF POWER

 AT CIRCUIT BREAKER OR FUSE AND TEST THAT 

THE POWER IS OFF BEFORE WIRING!

  TO BE INSTALLED AND/OR USED IN ACCORDANCE WITH ELECTRICAL CODES AND REGULATIONS.

  IF YOU ARE NOT SURE ABOUT ANY PART OF THESE INSTRUCTIONS, CONSULT AN ELECTRICIAN.

Method 1:

1.

  Mount the panel receptacle behind the panel as shown 

(up to 1/8" – 0.125" panel thickness).

2.

  Place the gasket and snap-back cover enclosure over the 

panel receptacle.

3.

  Place (3) #8-32 round head screws through the mounting 

holes and tighten with (3) #8-32 nuts. Torque screws to  
6 in-lbs. 

NOTE:

 No installation hardware included. Leviton 

recommends stainless steel screws with a head diameter 
NOT to exceed 0.300".

Method 1:

1.

  Mount the panel receptacle behind the panel as shown 

(up to 1/8" – 0.125" panel thickness).

2.

  Place the gasket and snap-back cover enclosure over the 

panel receptacle.

3.

  Place (4) #10-32 round head screws through the mounting 

holes and tighten with (4) #10-32 nuts. Torque screws to 8 
in-lbs. 

NOTE:

 No installation hardware included. Leviton 

recommends stainless steel screws with a head diameter 
NOT to exceed 0.350".

Snap-Back Cover

Couvercle autofermant 

Cubierta posterior

Receptacle

Prise 

Receptáculo

Mounting screw (4)

Vis (4) 

Tornillo de montaje (4)

Mounting nut (4)

Écrou (4) 

Tuerca de montaje (4)

Gasket

Joint d’étanchéité 

Empaquetadura

Panel

Panneau 

Panel

Method 2:

1.

  Mount the panel receptacle in front of the panel as shown.

2.

  Place the gasket and snap-back cover enclosure over the 

panel receptacle.

3.

  Place (3) #8-32 round head screws through the mounting 

holes and tighten with (3) #8-32 nuts. Torque screws to  
6 in-lbs. 

NOTE:

 No installation hardware included. Leviton 

recommends stainless steel screws with a head diameter 
NOT to exceed 0.300".

Method 2:

1.

  Mount the panel receptacle in front of the panel as shown.

2.

  Place the gasket and snap-back cover enclosure over the 

panel receptacle.

3.

  Place (4) #10-32 round head screws through the mounting 

holes and tighten with (4) #10-32 nuts. Torque screws to 8 
in-lbs. 

NOTE:

 No installation hardware included. Leviton 

recommends stainless steel screws with a head diameter 
NOT to exceed 0.350".

PK-93724-10-02-0C

INSTALLATION

ENGLISH

15 SERIES

16 SERIES

Snap-Back Cover

Couvercle autofermant 

Cubierta posterior

Receptacle

Prise 

Receptáculo

Mounting 

screw (3)

Vis (3) 

Tornillo de

montaje (3)

Mounting nut (3)

Écrou (3) 

Tuerca de montaje (3)

Gasket

Joint d’étanchéité 

Empaquetadura

Panel

Panneau 

Panel

Snap-Back Cover

Couvercle autofermant 

Cubierta posterior

Receptacle

Prise 

Receptáculo

Mounting screw (3)

Vis (3) 

Tornillo de montaje (3)

Mounting nut (3)

Écrou (3) 

Tuerca de montaje (3)

Gasket

Joint d’étanchéité 

Empaquetadura

Panel

Panneau 

Panel

Snap-Back Cover

Couvercle autofermant 

Cubierta posterior

Receptacle

Prise 

Receptáculo

Mounting screw (4)

Vis (4) 

Tornillo de montaje (4)

Mounting nut (4)

Écrou (4) 

Tuerca de montaje (4)

Gasket

Joint d’étanchéité 

Empaquetadura

Panel

Panneau 

Panel

FOR CANADA ONLY  - 

For warranty information and/or product returns, residents of Canada should contact Leviton in writing at 

Leviton Manufacturing of Canada Ltd to the 

attention of the Quality Assurance Department, 165 Hymus Blvd, Pointe-Claire (Quebec), Canada H9R 1E9

 or by telephone at 

1 800 405-5320.

WEB 

VERSION

Reviews: