background image

Tynetec, a business unit of Legrand Electric Ltd 

Cowley Road, Blyth Riverside Business Park, Blyth, Northumberland, NE24 5TF. 

Tel: +44 (0) 1670 352371    www.tynetec.co.uk 

Trusted Technology 

Caring for People 

869MHz Dual Smoke 
& CO Transmitter 

 

 
 

 

 
_________________________________________________________________________

 

________________________________________________________________ 

 
 

 
 

 

 

  Doc No. FM0866 V1.03 Page 1   

 

 

 

 

 

 

 
 
 

 

Fixed trigger device 

 

Compatible with Reach IP, Advent XT2 & Carer Response 

 

Transmitter housed in single gang surface pattress 

 

2 normally open clean contact trigger inputs 

 

80mm flying leads and screw connectors 

 

Factory programmed with smoke & CO alarm codes 

 

5 Year Lithium battery (typical)  

 

Low battery warning 

 

Operating Temperature: +5

o

C to +40

o

C  

 

Telecare Transceiver: 869.2125MHz Class 1.5 

 

Digital Heartbeat 

 

Weight: 140 grams 

 

Dimensions: 87mm x 87mm x 40mm (HxWxD) 

 

Product Code: ZXT870  
 

 

The dual transmitter can be connected to third-party 
smoke and CO detectors to initiate an alarm call on an 
Advent XT2 assisted living system, a Reach IP at-home 
alarm unit or a Carer Response local Carer alarm.  

 

The third-party detectors the transmitter is being 
connected to must have momentary action, normally 
open clean contact relay outputs that close on alarm. 

 

The transmitter is factory programmed with smoke and 
CO alarm AALRP radio codes.  

 

Positioning

 

The boxed transmitter should be wall mounted in the 
same dwelling as the smoke and CO detectors. The boxed 
transmitter is suitable for indoor locations only.   

 

 
 
 
 
 
 

Alarm Condition

 

When a third-party smoke or CO alarm is activated the 
relevant alarm call type will be transmitted. A new alarm 
will not be triggered until the detector has reset and is 
activated again.  

 

Low Battery Condition

 

A low battery condition will be reported automatically to 
the Alarm Receiving Centre (ARC) or the local Manager. 
The transmitter should be replaced as soon as possible 
within 30 days. The transmitter can be returned to Tynetec 
for battery replacement.  

 

Out of Range Notification (Reach IP)

 

The Reach IP can monitor all radio peripheral devices to 
determine whether they have been damaged or removed 
from an installation. Should the Reach IP be unable to 

detect a device’s heartbeat it will auto

matically generate a 

“radio out of range” notification. Firstly

, investigate if 

there’s a genuine reason for the alert, if not, arrange for 

the peripheral device to be replaced immediately.  

The “Radio 

out of range t

imer” can be set from 30 hours to 

99999 

hours in Pulse CMP. “Radio 

s

upervision” can be 

disabled by unchecking the tick box associated with each 
peripheral device in Pulse CMP.

 

 

Maintenance

 

Test the transmitter once every month. 

 

Disposal

 

Waste electrical products should not be disposed 
of with normal household waste. The unboxed 
transmitter is ideally suited for disposal within 
the waste electronic and electrical equipment 

(WEEE) recycling scheme.  
Please recycle where facilities exist.  
Check with your local authority or contact your supplier for 
recycling/disposal advice. 

 

Warning

 

The transmitter contains a Lithium battery. If tampered 
with the battery may be damaged and create a fire hazard. 
No attempt should be made to remove or replace the 
battery. Do not incinerate. 

 

 

 

 

 

Reviews: