background image

Order code: LEDJ185

UV 100W COB Flood 

1 x 100W UV LED  

User Manual

Summary of Contents for UV 100W COB Flood LEDJ185

Page 1: ...Order code LEDJ185 UV 100W COB Flood 1 x 100W UV LED User Manual ...

Page 2: ...t open the equipment and do not modify the unit Do not connect this equipment to a dimmer pack Do not switch the equipment on and off in short intervals as this will reduce the system s life Only use the equipment indoors Do not expose to flammable sources liquids or gases Always disconnect the power from the mains when equipment is not in use or before cleaning Only handle the power cable by the ...

Page 3: ...nels 1 or 2 selectable Stand alone sound active and master slave modes 0 100 dimming with variable strobe 4 push button menu with LED display Captive power connection 3 pin XLR in out sockets Fan cooled Supplied with hanging bracket and filter frame Optional 10 ELUM102 or 25 ELUM103 lenses Optional Barn Doors ELUM041C UV 100W COB Flood Specifications UV 100W COB Flood Power consumption 110W Power ...

Page 4: ...h speed by selecting between F 00 F 99 Press the ENTER button to confirm the setting To exit out of any of the above options press the MODE button Slave mode Press the MODE button on the rear of the unit to show SLAU on the LED display and press the ENTER button to confirm the setting The unit will now run in sequence with the master unit To exit out of any of the above options press the MODE butt...

Page 5: ... a language allowing all makes and models of different manufactures to be linked together and operate from a single controller as long as all fixtures and the controller are DMX compliant To ensure proper DMX data transmission when using several DMX fixtures try to use the shortest cable path possible The order in which fixtures are connected in a DMX line does not influence the DMX addressing For...

Page 6: ...5 pin XLR DMX connectors Some manufactures use 5 pin XLR connectors for data transmission in place of 3 pin 5 pin XLR fixtures may be implemented in a 3 pin XLR DMX line When inserting standard 5 pin XLR connectors in to a 3 pin line a cable adaptor must be used The diagram below details the correct cable conversion Termination reduces signal transmission problems and interferance it is always adv...

Page 7: ...possible harm to the environment or human health from uncontrolled waste disposal please separate this from other types of wastes and recycle it responsibly to promote the sustainable reuse of material resources Household users should contact either the retailer where they purchased this product or their local government office for details of where and how they can take this item for environmental...

Page 8: ...www prolight co uk 8 UV 100W COB Flood User Manual ...

Reviews: