background image

INSTRUCTION MANUAL

PLEASE READ INSTRUCTION BEFORE COMMENCING INSTALLATION AND RETAIN FOR FUTURE REFERENCES. 

! Electrical products can cause death or injury, or damage to property. If in any doubt about the installation or use of 

this product, consult a competent electrician

                                                                                                Note:

Product technical information and specification may change over time without prior notification. For the latest technical 

information please visit our web site www.ledgrouprobus.com or robusdirect.com

Issue 1 040517

Page 1

Information for the Product user:

1. Please note the requirement to dispose of Waste Electrical & Electronic Equipment separately from household waste (WEEE marked 

    with crossed out wheelie bin symbol). 

2. Please consider your role in contributing to re-use and recycling by returning this product at end of life to a collection centre for waste 

    electrical equipment or a Civic Amenity site, or to a retail outlet from which you are purchasing a replacement.

3. This equipment may contain substances that are hazardous to health and the environment if disposed of carelessly.  It is important that 

    it is separated from normal household waste and recycled in the WEEE chain

4. The “crossed out wheelie bin symbol” on a product indicates this equipment must not be disposed of in normal household waste, but 

    should be disposed of according to local WEEE regulations

The Installation must be carried out by a qualified electrician

Installatie

LEES DE INSTRUCTIES VOORDAT U BEGINT MET DE INSTALLATIE EN HOU ZE BIJ VOOR LATER. ! Elektrische 

producten kunnen de dood of letsel veroorzaken of eigendommen beschadigen. Als u twijfelt over de installatie of het 

gebruik van dit product, raadpleeg dan een erkende elektricien

                                                                                          Opmerkingen: 

Technische gegevens en specificaties van dit product kunnen zonder voorafgaande kennisgeving wijzigen. Ga voor de 

meest recente technische gegevens naar onze website www.ledgrouprobus.com of robusdirect.com

Informatie voor de gebruiker van het product:

1. Hou bij het verwijderen van afval rekening met de regeling voor afgedankte elektrische en elektronische apparatuur, gescheiden van 

    gewoon huishoudelijk afval (AEEA, pictogram van een kliko met een kruis erdoorheen).

2. Neem uw verantwoordelijkheid op het vlak van hergebruik en recycling door dit product aan het einde van zijn levenscyclus in te 

    leveren bij een inleverpunt voor elektronisch afval, een milieupark of een winkel waar u een nieuw product koopt.

3. Deze apparatuur kan stoffen bevatten die gevaarlijk zijn voor de gezondheid en het milieu indien ze onachtzaam wordt weggegooid. 

    Het is belangrijk dat ze gescheiden gehouden wordt van het normaal huishoudelijk afval en gerecycled wordt in het netwerk voor 

    AEEA.

4. Het pictogram van een kliko met een kruis erdoorheen op een product betekent dat dit apparaat niet samen met het gewone 

    huishoudelijk afval mag worden 

De installatie dient te worden uitgevoerd door een elektricien

EN

NL

PROTON 360 DEGREE PIR WITH FLUSH FRONT COMPLETE WITH ACCESSORY

SHIELD TO NARROW BEAM ANGLE

RPR360PIRF-01

1. Ensure mains supply is switched off before commencing work.

2. Select suitable location for mounting the sensor.

3. Mark 62mm cut-out hole in the ceiling, check location of buried cables, pipes and other building

    services before cutting.

4. Remove the terminal cover and cable clamp screws.

5. Connect cables as per figure 5. Live In (Brown) to L, Live Out (Brown) to L’ and Neutrals to N.

6. Refit the terminal cover and cable clamp.

7. Hold retention springs vertically, push the sensor through the cut-out until the springs come down on the

    upper side of the plasterboard. Ensure the is secure and the bezel is tight against the ceiling.

8. Reduce detection range using detection shield.

Installation

Walk testing can be carried out to determine detection area with slow walking pace. When the sensor

detects movement, the load will be switched on for the pre-set time. For the walk test turn Lux

control toward the Sun position (Max) and set time delay to 10s. When finished, set controls to desired levels. Note: Once

sensor has been triggered, subsequent detection restarts timing period from beginning, so light stays on until set time elapses

after last triggering.

ADJUSTING SETTING

: Pull down inner part of sensor to expose controls

.

LUX CONTROL LEVEL:

The Sun position (2000 Lux) denotes that when there is movement the load will be switched on during the day and at night. The

minimum Lux setting 3 Lux means that the load will be turned on by sensor only at night. Lux settings can be adjusted from 3 –

2000 Lux by rotating the dial.

ADJUSTING THE TIME DELAY:

The Time Delay is “the length of time that the sensor switches the load ‘on’ after

activation”. The duration time can be adjusted from 10 (±3) seconds to 15 (±2) minutes.

 -20°C < Ta < +40°C, 220-240V~50/60Hz, Class II, IP20
Rated load: 
Incandescent : Max. 1200W, Fluorescent / LED: Max. 300W
Mounting Height:             2.2m to 2.8m
Detection Range:            5m

Lux Level Adjustment:   3-2,000 Lux
Time Delay:                   10 (±3) Seconds - 15 (±2) Minutes
Suitable for mounting on a normally flammable surface.

Test:

PROTON 360 GRADEN PIR MET VERZONKEN VOORKANT, GELEVERD MET 

BIJHORENDE KAP OM DE DETECTIEHOEK TE VERMINDEREN

RPR360PIRF-01

1. Zorg dat het lichtnet is uitgeschakeld voordat u begint.

2. Kies een geschikte montageplaats voor de sensor.

3. Markeer een uitsparing van 62mm op het plafond en zorg dat u geen verborgen kabels, leidingen en andere voorzieningen 

    van het gebouw kunt beschadigen voordat u de uitsparing maakt

4. Verwijder de schroeven van de klembeschermer en kabelklem.

5. Sluit de kabels aan zoals op afbeelding 5. Stroom in (Bruin) op L, Stroom uit (Bruin) op L’ en Neutraal op N

6. Plaats de klembeschermer en kabelklem opnieuw.

7. Houd de borgring verticaal, duw de sensor door de uitsparing tot de veren naar beneden komen tegen de bovenkant van de 

    gipsplaat. Zorg dat alles goed vast zit en de afgeschuinde ring goed aansluit op het plafond.

8. Verminder het detectiebereik aan de hand van de detectiekap.

Om het detectiebereik te bepalen, kunt u langzaam voorbij wandelen. Wanneer de sensor beweging detecteert, wordt de 

belasting ingeschakeld gedurende de vooraf ingestelde tijdsduur. Zet voor de wandeltest de Lux-instelling op de Zon-positie 

(Max) en de tijdsduur op 10s. Stel wanneer u klaar bent de gewenste waarden in. Opmerking: Wanneer de sensor wordt 

geactiveerd, wordt de tijdsduur bij bewegingsdetectie herhaald, dus de lamp blijft branden tot de ingestelde tijdsduur verstreken 

is na de laatste activering.

AFSTELLING: 

Trek het binnenste deel van de sensor omlaag om de bediening bloot te leggen.

DE LUX-INSTELLING AFSTELLEN:

De Zon-positie (2000 Lux) betekent dat bij beweging de belasting zowel overdag als ‘s nachts wordt ingeschakeld. De minimum 

Lux-instelling van 3 Lux betekent dat de belasting enkel ‘s nachts wordt ingeschakeld door de sensor. De Lux-instellingen 

kunnen worden afgesteld van 3 tot 2000 Lux door aan het wieltje te draaien.

DE TIJDSDUUR AFSTELLEN:

De Tijdsduur is het “tijdsinterval dat de sensor de belasting inschakelt na activering”. De tijdsduur kan worden ingesteld van 10 

(±3) seconden tot 15 (±2) minuten.

 -20°C < Ta < +40°C, 220-240V~50/60Hz, Klasse II, IP20
Nominale belasting: 
Gloeilamp: Max. 1200W, Fluorescentielamp / LED: Max. 300W
Montagehoogte:    

2,2m tot 2,8m

Detectiebereik:             5m

Luxbereik:    3-2.000 Lux
Tijdsduur:    10 (±3) Seconden - 15 (±2) Minuten
Geschikt voor montage op een normaal ontvlambaar oppervlak.

Test: