manualshive.com logo in svg
background image

USER MANUAL

LL STAGE SPOT VARIO OPTIC

Leader Light s.r.o.

M.Gorkeho 33

SK-052 01 Spisska Nova Ves

Slovakia

www.leaderlight.eu

All dimensions are in millimeters

WARNING!!!

Carefully read before installing, powering or servicing.
Nothing to do if anything misunderstand! Installation can be done only 

by a qualified professional in accordance with relevant local codes.

01    SAfETy INfORMATION

01.1 Risk of eyes damage

Do not look directly into LED lamps.

Do not look into light beam from a distance of less than 40 cm (16 inches)!

-

-

01.2 Protection from electric shock

Shut down power before installation or maintenance.

Luminaries and recommended AC power supply must be installed by a qualified 

professional in accordance with relevant local codes. Only acceptable source of AC power 

and frequency that complies with local building and electrical codes to use.

Do not use or do not connect the products if the power cable, power plug or fixtures are any 

way damaged, wet, or if they are overheating.

Do not modify, alter, or attempt to service the LeaderLight appliance. Doing so will void the 

warranty.

Before removing or installing any cover or part of appliance disconnect it from AC power.

Appliance always connect to earth (eltech.).

-

-

-

-

-

-

01.3 fire prevention

Follow all safety consideration.

Thermostatic switches or fuses never to bypass.

Device never shield. Around the axis of the fitting (180°) must be maintained space for 

cooling. Minimum distance from the surrounding objects must be 100mm (4 in.) (figure 1.1).

LEDs never direct cover with filters or other materials.

Allowing max. ambient temperature is 40°C (104°F).

Luminaries never use without mounting brackets. The housing never install directly to the 

surface. 

-

-

-

-

-

-

02 PROdUCT SPECIfICATION

02.1 Technical Specification

LEd

INdICATION

STATUS

POWER (Red)

blinking – 2Hz

OK - inside fixture is everything correct

DATA (Green)

light off

NO DMX512 signal

DATA (Green)

blinking – 4Hz

OK- income correct DMX512 signal

DATA (Green)

fast blinking

NON correct digital signal

POWER (Red)

alternate blinking

Autotest function

DATA (Green)

Control LEds Indication

POWER

DATA

03 INSTALLATION

03.1 Unpacking

Unpack carefully.

This is electronic equipment and should be handled carefully.

Damaged delivered package or if are any mechanical parts broken – it must be claim 

immediately by the transport company. Photo pictures as evidence are valuable for 

future claim.

-

-

-

03.2 Physical installation

Loading capacity of bearing area has to be at least 10 times the weight of all device 

clusters (luminaries, clamps, cables, ...).

Hairbreadth from combustible materials is 0,5m.

Before physical installation insert the optic modul on front of luminary. The optic 

installation is easy and fast by 1 screw 

(figure Nr. 2.1).

-

-

-

03.3 Connecting to AC power

To tackle all Safety Information- 01!

For protection from electric shock, the device must be grounded (earthed)!

It is not necessary to open the fixture before power supply.

Power supply is solved simple with Neutrik PowerCon connectors.

The fixture is equipped with auto-switching power supply that automatically adjusts to 

any 50-60Hz AC power source from 100-260V.

Cord plug connections:

-

-

-

-

-

-

©MMX - Leader Light – All right reserved

02.2 Back panel

If you have any question please, contact [email protected]

COMPLIMENTS ON yOUR PURCHASE!

Symbol

Pin

Wire Colour

Screw (US)

L

live

brown

yellow or brass

N

neutral

blue

silver

ground (earth)

yellow/green

green

03.4 Control data connecting

Control data cable length is specified by Norm IEC929 Annex E4.

It is not necessary to open the fixture before connecting of DMX512 control signal. 

Interconnections are realized by Neutrik XLR 5pin IN/Out connectors.

Pin connections:

                            Pin 1 – ground

                            Pin 2 – signal negative

                            Pin 3 – signal positive

-

-

-

Content:
01   SAfETy INfORMATION

        01.1 Risk of eyes damage

        01.2 Protection from electric shock

        01.3 Fire prevention

02   PROdUCT SPECIfICATION

        02.1 Technical Specification

        02.2 Back panel

03   INSTALLATION

        03.1 Unpacking

        03.2 Physical installation

        03.3 Connecting to AC power

        03.4 Control data connecting

        03.5 DMX channels

04   MAINTENANCE

Edition: A - 2010

Lamp type:

16xRGBA OneChip LED 

*

Lifetime:

Long 60 000 hrs 90% degradation

Vario Optic:

10°, 25°, 40° and EL (Eliptical 15°x90°)

Control data connection:

DMX 512 In/Out with 5pin XLR

Input power:

150W

Power connection:

100-260V AC In/Out PowerCon

Net weight:

3kg

IP:

IP20

Ambient temp. (Ta):

Maximum 40°C

Cooling:

Conventional

Materials and finish:

Housing: powder-painted anodized aluminium in black 

(other colours on request)

Installation:

Surface mounting

Without optic:

LL36 203

With optic:

LL36 202

ENVIRONMENT

Do not throw away the appliance with the normal household waste at the end 

of its life, but hand it in at an official collection point for recycling. By doing 

this, you help to preserve the environment.

Note: LED:      RGBA-Red and Green and Blue and Amber

Dip options

» Rotating DIP address 000÷511

“100“ “10“ “1“

Control LEDs

POWER

DATA

MODE &  ADDRESS

DMX Out

XLR-5pin

DMX In

XLR-5pin

DMX512

Power In

PowerCon

POWER

WARNING!!!

!

!

Non-minimum distance and / or non-use the original brackets is at your own risk!

195

163,2

215

following items are included:

1. LL STAGE SPOT VO without optic
- LL STAGE SPOT 16 RGBA , 

without optic

1 pc.

- PowerCon type “A“ + “B“

1 pc.

- User manual

1 pc.

2. LL STAGE SPOT VO with optic 
- LL STAGE SPOT 16 RGBA , 

without optic

1 pc.

- LL VARIO OPTIC SPOT 16 25°

1 pc.

- PowerCon type “A“ + “B“

1 pc.

- User manual

1 pc.

Additional items needed:

- Data cables with XLR 5pin Female/Male

1 pc.

- Controller compatible with DMX 

1 pc.

- Mounting accessories as necessary
Surface mounting:

- Screws and washers 1xM12 or 2xM10

Отзывы: