background image

 

Le Maitre

®

 MVS Hazer  

Operating Manual 

 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 

 
 
 

The MVS is a High technology, feature rich Hazer machine. 

 

All features are variable and storable. 

 

High Haze Output is variable down to a whisper 

 

Twin Projection fans are variable from 2800ft/min velocity down. 

 

Haze output direction is electronically variable from 0 to 90 degrees 

 utilising differential air flow techniques. 

 

Four Channel DMX 512 built in.  Selectable channel usage. 

 

Digital display and control panel. 

 

Uses the unique Le Maitre Hazing Fluid. 

 

Separate fluid supply allows the machine to be positioned at virtually any angle.  

 

Summary of Contents for MVS

Page 1: ...in Projection fans are variable from 2800ft min velocity down Haze output direction is electronically variable from 0 to 90 degrees utilising differential air flow techniques Four Channel DMX 512 built in Selectable channel usage Digital display and control panel Uses the unique Le Maitre Hazing Fluid Separate fluid supply allows the machine to be positioned at virtually any angle ...

Page 2: ...s the haze come into contact with guides or structures which normally leads to a build up of condensate and residues Two communicating processor devices are employed in the control of the machine allowing for efficient and dedicated control of their connected devices The control panel processor includes non volatile memory which allows for all settings to be retained in that memory and recalled up...

Page 3: ... take note of the warning labels Do not touch or obstruct these nozzles Under adverse conditions tiny particles of hot fluid could issue close to the machine Never aim at persons or allow such operating conditions to occur and maintain a 3m safety clearance There are ventilation holes at the rear of the machine these should not be covered or obstructed Similarly the fan inlet holes on the side of ...

Page 4: ...ons H 340mm W 160mm D 340mm Weight Fluid Not Included 12Kgm Technological Improvements Combined manual and DMX control Memory Storage Simplified high current control of vapour tube using advanced software High power air pump Electronic control of Haze output Projection distance and Angle of haze output Advanced and unique motor control stabilizes fan output over the widest possible range Larger di...

Page 5: ...of foreign particles which may reduce the efficiency of the external in line filter If it is felt that there is a reduction in the performance of the machine then this filter should be un plugged from the silicon tubing and reversed washed Never operate the machine with this filter removed Any spillage should be cleaned away The fluid does not require anything other than a water based cleanser Ope...

Page 6: ...e as the Haze output value so that the machine can default to producing Haze when the machine is switched on To default to DMX on start up Disconnect any DMX cables and select DMX mode until DoF is displayed and the LED blinks Press DMX and STORE buttons together and hold The LED will blink quickly and store this setting To revert back select the manual mode and press the MANUAL and STORE buttons ...

Page 7: ...The Haze button allows an instant on off switching in the Manual mode so that the haze output setting need not be reduced to zero in order to switch the effect off 7 ...

Page 8: ...al is being received If the selection on the display is set to Haze Projection Direction or Sweep then DOFF will also appear if the dmx signal is not correct The main display will show the variation in value as the dmx signal is varied for the selected feature Note Once DMX is selected the SELECT buttons are inhibited so in order to display the DMX variations the required feature Haze Projection e...

Page 9: ...p Angle 90 degrees 45 to 90 sweep The DMX channel assignment and channel options are irrelevant in Manual mode All that is required now is the use of the Haze button Press for On Press again for Off If the settings are required to set as defaults in memory then at each final adjustment press the Manual and Store keys at the same time When the machine is switched on again these settings will be res...

Page 10: ... base plate will allow the machine to be positioned in a vertical mode but at a 45 degree angle so that the haze output angle can be varied from 45 to 135 degree coverage For even more versatility this base plate can be mounted such that the MVS is at 45 degrees in two planes as shown on the front page of this manual This will give a 45 to 135 degree spread at 45 degrees from the horizontal If req...

Page 11: ...This unit fits externally in the fluid supply line and will normally not require any attention Should however the filter become clogged with debris the performance of the MVS will be reduced Should this occur detach the filter and wash in warm soapy water flush with clean water and re attach to the silicon supply tubing Fan System Depending upon the environment in which the MVS is used it may be r...

Page 12: ...same time tight enough to provide a good electrical connection Push on silicon tubing supplying the fluid and air drive is easily removed from the input end It is best to use nyties since this will add security to the fluid and air supply connections After tube replacement and having checked that all parts are as they should be the tube should be run through a bedding in period where any tendency ...