background image

CiS-Nr.: 360.610.0110
Reg 10508/0605
Version 2/09.05
© Elektronik-Systeme LAUER GmbH & Co. KG

User manual

EPC PM 1200

EPC PM 1500

EPC PM 1700

EPC PM 2100

EPC PM Box

Summary of Contents for EPC PM 2100

Page 1: ...CiS Nr 360 610 0110 Reg 10508 0605 Version 2 09 05 Elektronik Systeme LAUER GmbH Co KG User manual EPC PM 1200 EPC PM 1500 EPC PM 1700 EPC PM 2100 EPC PM Box...

Page 2: ...a software back up copy for private use We reserve the right to make amendments to the manual without prior notice We can not guarantee the accuracy and correctness of the programmes and data stored o...

Page 3: ...ic Names of pushbuttons to be used menus or other screen elements as well as brand names are shown in italic letters Necessary basic knowledge A solid Knowledge of the personal computer and Microsoft...

Page 4: ...est level is used if various danger levels occur When a warning advise with a warning triangle warns about perso nal damage then an additional warning for material damage can be added Qualified person...

Page 5: ...otherboard slots memory module 15 3 Putting in to operation 17 3 1 Power supply 17 3 2 Earthing system 18 3 3 Assembly 19 3 4 operating system 20 3 5 BIOS settings 21 3 6 Important items regarding sof...

Page 6: ...o operation with our customers persuasive concepts are developed harmonising efficiently man and interface Proximity to customers the direct dialog is the basis of our success Support contact Telephon...

Page 7: ...ces running on DC supply comply with the EC directive 89 336 EEC electromagnetic compatibility and are according to the CE marking designed for following applications Application Standard Emitted inte...

Page 8: ...Elektronik Systeme LAUER GmbH Co KG Kelterstr 59 72669 Unterensingen Tel 07022 9660 0 Fax 07022 9660 103 0 8...

Page 9: ...e pass is supplied with every appliance It contains important information for the user Ready to hand are important address data serial number then there are the components and type designation corresp...

Page 10: ...n contact of the EPCPM Note Key Version of the EPC PM with keyboard on the front plate you can install the program Keyconf under E Tools Keyconf for configuring the individual keys The software is sel...

Page 11: ...ER GmbH Co KG Kelterstr 59 72669 Unterensingen Tel 07022 9660 0 Fax 07022 9660 103 11 2 Description 2 1 Installation The installation of the PPC is independent of the display size shown as follows 1 F...

Page 12: ...rensingen Tel 07022 9660 0 Fax 07022 9660 103 12 2 2 Display Display sizes of 12 15 17 and 21 are available alternatively with Touch or keyboard and Touch Pure Touch variants available in 12 15 17 and...

Page 13: ...Elektronik Systeme LAUER GmbH Co KG Kelterstr 59 72669 Unterensingen Tel 07022 9660 0 Fax 07022 9660 103 13 2 3 Ports 24 V panel 2 Description...

Page 14: ...Elektronik Systeme LAUER GmbH Co KG Kelterstr 59 72669 Unterensingen Tel 07022 9660 0 Fax 07022 9660 103 14 230 V panel 2 Description...

Page 15: ...ith the supplied materials Notice Individual slots may be part of the supply depending on configuration and customer requirements The quality of the memory module may influence the system stability Pl...

Page 16: ...Elektronik Systeme LAUER GmbH Co KG Kelterstr 59 72669 Unterensingen Tel 07022 9660 0 Fax 07022 9660 103 16 2 Description...

Page 17: ...voltage in accordance with EN60950 The controlling transformer has to comply with EN60742 Check the power supply system with the relevant data on the type plate All cable connections have to be checke...

Page 18: ...interference Appliance and switch board have to be connected to the nearest possible central earthing point make sure of a possibly low inductive connection between appliance and switch board All data...

Page 19: ...heat generated in the appliance a free space for air circulation of 100 mm has to be provided around the appliance The assembly takes place by hexagon nuts or retaining blocks depending upon the vers...

Page 20: ...S Windows XP professional German and English C and D NTFS depending on the configuration the respective user interface of the installed operating system appears once the EPC has booted from the hard d...

Page 21: ...660 0 Fax 07022 9660 103 21 3 5 BIOS settings Settings DFI ACP G5M100N Switch on the EPC PM and press the DEL i e Entf button shown in the first screen image to start the set up 3 Putting in to operat...

Page 22: ...D CDundCF werecorrectlyrecognised AdvancedBIOSFeatures First Boot Device HDD 1 AdvancedBIOSFeatures SecondBootDevice HDD 0 AdvancedBIOSFeatures ThirdBootDevice Disabled AdvancedBIOSFeatures BootOtherD...

Page 23: ...an electron beam for image formation and therefore no improvement is achieved from a higher setting Higher settings can even result in the destruction of the graphic board display install the touch dr...

Page 24: ...llation 6 10 Windows 2000 XP technical data check the BIOS entries when re installing SerialTsharc 12Touch Controller Com 3 check the BIOS entries 3E8 hex IRQ 4 9600 bps Carry out the SETUP EXE under...

Page 25: ...ik Systeme LAUER GmbH Co KG Kelterstr 59 72669 Unterensingen Tel 07022 9660 0 Fax 07022 9660 103 25 follow the instructions on the monitor press CONTINUE accept the license provisions 3 Putting in to...

Page 26: ...nik Systeme LAUER GmbH Co KG Kelterstr 59 72669 Unterensingen Tel 07022 9660 0 Fax 07022 9660 103 26 select the Auto detect Function or manually select the technical connection data 3 Putting in to op...

Page 27: ...9660 103 27 Press the finalise Button and follow the instructions for a re start After a re start of the operating system you will find amongst the programs the entry Hampshire Control Panel Calibrate...

Page 28: ...ation window for the automatic driver search of the grafic board driver The grafic driver is on the delivered Driver CD or on Partition E EPC PM Grafic Start SETUP EXE in the directory UTILITIES and a...

Page 29: ...all up the EXE file from the drive directory drive E Driver EPC PM LAN for the installation of the second network card confirm each installation step and re start the EPC PM at the end of the installa...

Page 30: ...Elektronik Systeme LAUER GmbH Co KG Kelterstr 59 72669 Unterensingen Tel 07022 9660 0 Fax 07022 9660 103 30 3 Putting in to operation...

Page 31: ...t damage the front panel of the EPC PM Open the appliance All operations to the opened appliance may only be carried out by authorised personnel Only the expansion of hardware with memory and plug in...

Page 32: ...9660 103 32 4 1 Changing the fan To change the fan you have to remove the left hand part of the rear enclosure To open the enclosure remove the marked screws with an Allen key Then lift the enclosure...

Page 33: ...103 33 Please note the correct location of the cable prior to pulling the cable out so that the new fan can be plugged in correctly Remove the protective cover of the fan and remove the fan with a Ph...

Page 34: ...9660 0 Fax 07022 9660 103 34 4 2 PCI board installation To install a PCI board the right hand side part of the rear enclosure has to be removed To open the enclosure remove the marked screws with an...

Page 35: ...Co KG Kelterstr 59 72669 Unterensingen Tel 07022 9660 0 Fax 07022 9660 103 35 A look at the opened appliance shows the 2 PCI slots and the board holder Remove the slot cover of the desired slot to in...

Page 36: ...GmbH Co KG Kelterstr 59 72669 Unterensingen Tel 07022 9660 0 Fax 07022 9660 103 36 Unscrew the board holder Insert your PCI board Please ensure a correct fit at the lower edge of the slot Screw your...

Page 37: ...r has to be re fixed To ensure an optimal use of the board holder we suggest that you put wide boards in the lower slots and narrow boards in the upper slots Following picture shows this once more in...

Page 38: ...nge To change the memory board you have to remove the left hand part of the rear enclosure To open the enclosure remove the marked screws with an Allen key Then lift the enclosure and pull out the fan...

Page 39: ...39 Put the enclosure to one side and you have a free view of the slots Pull out ribbon cable see arrow and move it to the top The picture shows a free and an occupied slot If a memory expansion is car...

Page 40: ...anged then the holding brackets have to be pushed outwards simultaneously The memory board is now loose and can be removed Locate the memory board vertically and push it down the brackets snap shut Be...

Page 41: ...E with integrated graphic up to UXGA Memory Slots 2x DDR SDRAM bis max 2GB Memory Compact Flash or 2 5 HD optionally with extended temperature range Extension Slots 2x PCI bis 220mm lang 1x CF Card Ty...

Page 42: ...10 Tr 30 Tf 5 Tr 20 Tf 10 Tr 15 Tf 10 Tr 15 Tf DisplayTechnology TN TN TN PVA PVA TouchscreenTechnology Resistiv Touch resolution 4096 x 4096 Punkte Keyboard Short stroke keys Life span short stroke...

Page 43: ...22 9660 103 43 5 1 Detailed drawings 5 1 1 EPC PM 1200 frontal view overall measurement 364 0 x 296 0 mm Front panel assembly aperture Aperture size 344 0 x 276 0 mm Type of mounting with 8 pieces int...

Page 44: ...LAUER GmbH Co KG Kelterstr 59 72669 Unterensingen Tel 07022 9660 0 Fax 07022 9660 103 44 view of the appliance s underneath lateral view Appliance s rear view lateral view View of the equipment top si...

Page 45: ...0 0 Fax 07022 9660 103 45 5 1 2 EPC PM 1500 frontal view overall measurement 452 0 x 357 0 mm Front panel assembly aperture Aperture size 429 0 x 334 0 mm Type of mounting with10 pieces into the front...

Page 46: ...LAUER GmbH Co KG Kelterstr 59 72669 Unterensingen Tel 07022 9660 0 Fax 07022 9660 103 46 view of the appliance s underneath lateral view Appliance s rear view lateral view View of the equipment top si...

Page 47: ...0 0 Fax 07022 9660 103 47 5 1 2 EPC PM 1700 frontal view overall measurement 480 0 x 377 0 mm Front panel assembly aperture Aperture size 454 0 x 351 0 mm Type of mounting with14 pieces into the front...

Page 48: ...LAUER GmbH Co KG Kelterstr 59 72669 Unterensingen Tel 07022 9660 0 Fax 07022 9660 103 48 view of the appliance s underneath lateral view Appliance s rear view lateral view View of the equipment top si...

Page 49: ...0 103 49 5 1 3 EPC PM 2100 frontal view overall measurement 527 0 x 419 0 mm Front panel assembly aperture Aperture size 498 0 x 390 0 mm Type of mounting with14 pieces into the front plate pressed in...

Page 50: ...Elektronik Systeme LAUER GmbH Co KG Kelterstr 59 72669 Unterensingen Tel 07022 9660 0 Fax 07022 9660 103 50 view of the appliance s underneath Rear view of the appliance lateral view 5 Technical data...

Page 51: ...ik Systeme LAUER GmbH Co KG Kelterstr 59 72669 Unterensingen Tel 07022 9660 0 Fax 07022 9660 103 51 5 1 4 EPC PM Box view of the appliance s underneath Rear view of the appliance lateral view 5 Techni...

Page 52: ...Elektronik Systeme LAUER GmbH Co KG Kelterstr 59 72669 Unterensingen Tel 07022 9660 0 Fax 07022 9660 103 52...

Reviews: