1500/2500 Chiller

®

Summary of Contents for SERIES 1500 POSTMIX

Page 1: ...d trademark of Lancer Corp For more Information visit lancerworldwide com or call Tech Support Warranty 800 729 1550 6655 Lancer Boulevard San Antonio TX 78219 custserv lancerworldwide com 2023 Lancer...

Page 2: ...applicable safety precautions must be observed To reduce the risk of fire electric shock damage to the equipment or personal injury when using this unit all instructions warnings on the product being...

Page 3: ...e unit to prevent personal injury before attempting any internal maintenance Only qualified personnel should service internal components of electrical control housing WARNING Make sure that all water...

Page 4: ...L 115 VAC 60 Hz 7 8 Amps 230 VAC 50 Hz 4 5 Amps WATER SUPPLY Min Inlet Pressure 25 psi 0 172 MPa Max Static Pressure 70 psi 0 483 MPA FITTINGS AT UNIT Inlets 3 8 inch barb Outlets 3 8 inch barb A B C...

Page 5: ...17 kg ELECTRICAL 115 VAC 60 Hz 16 Amps 230 VAC 50 Hz 7 5 Amps WATER SUPPLY Min Inlet Pressure 25 psi 0 172 MPa Max Static Pressure 70 psi 0 483 MPA FITTINGS AT UNIT Inlets 3 8 inch barb Outlets 3 8 in...

Page 6: ...untertop support the weight of the chiller Is chiller located away from direct sunlight or overhead lighting Not in area where water jet could be used TOOLS REQUIRED Oetiker Pliers Tubing Cutters Wren...

Page 7: ...g base NOTE DO NOT LAY UNIT ON ITS SIDE OR BACK ATTENTION Failure to maintain specified clearance will cause the compressor to overheat and will result in compressor failure ATTENTION 6 15 1 The chill...

Page 8: ...5 gals 19 L of distilled water ATTENTION Make sure the overflow tube is not covered to allow water from the water bath tank to escape as needed NOTE 8 Carefully pour water into the water bath tank un...

Page 9: ...ning solution from the syrup lines using clean warm water 8 Prepare sanitizing solution as described in the Cleaning and Sanitizing Solutions section 9 Place syrup lines into sanitizing solution and a...

Page 10: ...to ensure smooth free syrup movement 4 Replace BIB pump Scheduled Maintenance MAINTENANCE As Needed Keep exterior surfaces of chiller clean using a clean damp cloth Daily With a clean cloth and warm...

Page 11: ...5 Replace condenser fan motor 6 Clean condenser 7 Replace with larger chiller Compressor does not start no hum gas cooler fan does not run and no ice bank 1 There is a five 5 minute compressor and con...

Page 12: ...nal on compressor Voltage must not drop below 90 of rated voltage 2 Refer to wiring diagram and correct 3 Replace starting relay Be sure to use correct relay Failure to use correct relay will cause co...

Page 13: ...1 82 1207 CAB ASSY LWR 1500E CHILLER 2 30 5535 FRONT PLATE 1500E CHILLER 3 23 0760 01 CAGE ASSY LG1500Y 6 1 1 4 82 2668 01 DCK ASY RF 1 3 115 60 EIBC NT 5 23 1776 BONNET ASSY SS 1500 ILLUSTRATIONS AN...

Page 14: ...Part No Description 1 82 0820 CAB ASSY LWR 2500 CHILLER 2 82 2670 DCK ASY RF 3 4 115 60 EIBC NT 3 23 0650 BONNET ASSY 2500Y SST 4 23 0798 01 CAGE ASSY 2500 REF 6 2 1 5 30 5218 FRONT PLATE 2500 REF 250...

Page 15: ...FAN MOTOR COMPRESSOR OVERLOAD C M S L M S WHEN STARTING UNIT OR IF CURRENT IS INTERRUPTED THERE IS A FIVE 5 MINUTE DELAY BEFORE THE COMPRESSOR FAN STARTS IMPORTANT Model 1500 AC POWER IN AGITATOR MOTO...

Page 16: ...Diagrams Model 1500 23 0910 Cage Assembly 4 Circuit S1 S2 S3 1500 Chiller 4 Circuit S4 S4 S3 S2 S1 S1 S2 S3 1500 Chiller 6 Circuit S4 S5 S6 S4 S3 S2 S1 S6 S5 CW PW PW CW Model 1500 23 0760 Cage Assemb...