background image

 

30

LCD 
Display

 

 

Function 

keys

 

Battery 
compartment

 

Stand

 

Hanging hole

SET key

 

Function 
keys

 

 

 WEATHER STATION  

 

 

Instruction Manual 

 
INTRODUCTION 

Congratulations on purchasing this weather station as an example of innovative design and 
quality piece of engineering. Providing time, date, calendar, indoor and outdoor temperature, 
indoor and outdoor relative humidity, and air pressure history information, this unit will never 
keep you guessing on current and future weather conditions. Operation of this product is 
simple and straightforward. By reading this operating manual, the user will receive a better 
understanding of the weather station together with the optimum benefit of all its features. 
 
 
 
 
 
 
 
 
 
 
 

 

 

FEATURES

 

 

The Weather Station

  

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 

DCF Radio controlled time with manual setting option 

 

Time reception ON/OFF setting 

 

Weekday, date and month display (year only in setting mode) 

 

Time zone option (-2h to +5h) 

 

Daylight saving time (DST) setting 

 

Alarm setting 

 

Temperature display in degree Celsius (°C) 

 

Indoor temperature display with MIN/MAX recordings 

 

Outdoor temperature display with MIN/MAX recordings with time and date received 

 

All MIN/MAX recordings can be reset 

 

Indoor and outdoor humidity display in RH% 

 

Weather forecast with weather tendency indicator 

 

Relative air pressure history for the past 12 hours 

 

LCD contrast setting 

 

Low battery indicator 

 

Table standing or wall mounting 

 

Thermo-Hygro Transmitter 

 

Remote transmission of outdoor temperature and humidity to weather 
station by 868MHz 

 

Wall mounting case 

 

Mounting at a sheltered place. Avoid direct rain and sunshine 

 
 
 
 
 
 
 

SETTING UP 

Note: This weather station receives only one outdoor transmitter.   

 

1. 

First, insert the batteries in the transmitter (see “How to install and replace batteries 
in the thermo-hygro transmitter
 above). 

2. 

Within 30 seconds of powering up the transmitter, insert batteries in the weather station 
(see “How to install and replace batteries in the weather station above). Once the 
batteries are in place, all segments of the LCD will light up briefly and a short signal 
tone will sound. Then the indoor temperature, humidity and the time as 0:00 will be 
displayed. If these information are not displayed on the LCD after 60 seconds, remove 
the batteries and wait for at least 60 seconds before reinserting them. Once the indoor 
data is displayed user may proceed to the next step. 

3. 

After the batteries are inserted, the weather station will start receiving data signal from 
the transmitter. The outdoor temperature and humidity data should then be displayed 
on the weather station. If this does not happen after 2 minutes, the batteries will need 
to be removed from both units and reset from step 1. 

4. 

In order to ensure successful 868 MHz transmission, the distance between the weather 
station and the transmitter should be within 100 meters (see notes on “Positioning 
and “868 MHz Reception”). 

5. 

Once the outdoor data reception test period is completed, the DCF tower icon in the 
clock display will start flashing in the upper left corner. This indicates that the clock has 
detected that there is a radio signal present and is trying to receive it. When the time 
code is received, the DCF tower becomes permanently lit and the time will be 
displayed. 

 

TO INSTALL AND REPLACE BATTERIES IN THE WEATHER STATION 

The weather station uses 3 x AAA, IEC LR3, 
1.5V batteries. To install and replace the 
batteries, please follow the steps below:

 

1. 

Insert finger or other solid object in the 
space at the bottom center of the 
battery compartment and lift up to 
remove the cover. 

2. 

Insert batteries observing the correct 
polarity (see marking). 

3. 

Replace compartment cover. 

TO INSTALL AND REPLACE BATTERIES IN THE THERMO-HYGRO 
TRANSMITTER
 

The outdoor thermo-hygro transmitter uses 2 x AAA, IEC LR3, 1.5V batteries. To 
install and replace the batteries, please follow the steps below:

 

1. 

Remove the battery cover by pushing the battery cover upwards with your 
thumb.  

2. 

Insert the batteries, observing the correct polarity (see battery 
compartment marking). 

3. 

Replace the battery cover on the unit.

 

 
 
 

 

Note: 
In the event of changing batteries in any of the units, all units need to be reset by following 
the setting up procedures. This is due to a random security code assigned by the transmitter 
at start-up. This code must be received and stored by the weather station in the first 3 
minutes of power being supplied to the transmitter.

 

 

DCF RADIO CONTROLLED TIME 

The time base for the radio controlled time is a Cesium Atomic Clock operated by the 
Physikalisch Technische Bundesanstalt Braunschweig which has a time deviation of less than 
one second in one million years. The time is coded and transmitted from Mainflingen near 
Frankfurt via frequency signal DCF-77 (77.5 kHz) and has a transmitting range of 
approximately 1,500 km. Your radio-controlled weather station receives this signal and 
converts it to show the precise time in summer or wintertime. 
The quality of the reception depends greatly on the geographic location. In normal cases, 
there should be no reception problems within a 1,500 km radius of Frankfurt.  

 

DCF reception is done twice daily at 02:00 and 03:00 am. If the reception is not successful at 
03:00 am, then the next reception takes place the next hour and so on until 06:00am, or until 
the reception is successful. If the reception is not successful at 06:00 am, then the next 
attempt will take place the next day at 02:00 am. 

 

If the tower icon flashes, but does not set the time or the DCF tower does not appear at all, 
then please take note of the following: 

 

Recommended distance to any interfering sources like computer monitors or TV sets is 
a minimum of 1.5 - 2 meters. 

 

Within ferro-concrete rooms (basements, superstructures), the received signal is 
naturally weakened. In extreme cases, please place the unit close to a window and/ or 
point its front or back towards the Frankfurt transmitter. 

 

During nighttime, the atmospheric disturbances are usually less severe and reception is 
possible in most cases. A single daily reception is adequate to keep the accuracy 
deviation below 1 second.

 

 

FUNCTION KEYS: 

 

Weather station: 
The weather station has 4 easy to use function keys: 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

SET key 

 

Press and hold for 2 seconds to enter manual setting modes: LCD contrast, time zone, 
time reception ON/OFF, DST ON/OFF, manual time setting and calendar 

 

To stop the alarm sound 

 

key 

 

To increase/change values in setting modes  

 

Toggle between time / date / humidity / seconds display 

 

To stop the alarm sound 

 

MIN/MAX key 

 

To toggle between the indoor and outdoor MIN/MAX temperature 

 

To decrease/change values in setting modes  

 

Press and hold for 3 seconds to reset ALL indoor/outdoor minimum/maximum 
temperature recordings to current readings 

 

To stop the alarm sound 

 

ALARM key  

 

To activate/deactivate the alarm and display alarm time 

 

Press and hold for 2 seconds to enter the alarm setting mode 

 

To stop the alarm sound 

 

To exit the manual setting mode 

 

LCD SCREEN  

The LCD screen is split into 3 sections displaying the information for time/calendar, indoor 
data, weather forecast and air pressure history, and outdoor data. 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

* When the signal is successfully received by the weather station, the outdoor transmission 
icon will be switched on. (If not successful, the icon will not be shown on LCD). The user can 
then easily see whether the last reception was successful (icon on) or not (icon off). 

 

MANUAL SETTINGS 

The following settings can be changed when pressing and holding the SET key: 

 

LCD contrast setting 

 

Time zone setting 

 

Time reception ON/OFF setting 

 

Daylight saving time (DST) ON/OFF setting 

 

Manual time setting 

 

Calendar setting 

 

LCD CONTRAST SETTING 

 

 

 

 
 

The LCD contrast can be set within 8 levels, from LCD 0 to LCD 7 (Default is LCD 4):  
1. 

The LCD contrast level starts flashing. 

2. 

Use the + or MIN/MAX key to select the level of contrast desired.  

3. 

Confirm with the SET key and enter the Time Zone Setting

 

TIME ZONE SETTING: 

 
 

 

 

The time zone default of the weather station is “0”. To set a different time zone: 
1. 

The current time zone value starts flashing.  

2. 

Use the + or MIN/MAX key to set the time zone. The range runs from -2h to +5h hours 
in 1-hour intervals. 

3. 

Confirm with the SET key and enter the Time Reception ON/OFF Setting

 

TIME RECEPTION ON/OFF SETTING 

In area where reception of the DCF-77 time signal is not possible, the DCF-77 time reception 
function can be turned OFF. The clock will then work as a normal quartz clock. (Default 
setting is “1” = ON).

 

 
 
 
 
 
 

1. 

The digit “1” will start flashing on the LCD. 

2. 

Use the + or MIN/MAX key to turn OFF (“0” = OFF) the time reception function. 

3. 

Confirm with the SET key and enter the Daylight Saving Time (DST) ON/OFF 
Setting
. 

 

Note: 

 

If the Time Reception function is turned OFF manually, the clock will not attempt any 
reception of the DCF time as long as the Time Reception OFF function is activated.  

 

 

The time reception “       “ and the “DCF” icons will not be displayed on the LCD.

 

 

DAYLIGHT SAVING TIME (DST) ON/OFF SETTING 

 
 
 
 
 
The daylight saving time (DST) function can be set ON/OFF. Default setting is “1” = ON:

 

1. 

The digit “1” will start flashing on the LCD. 

2. 

Use the + or MIN/MAX key to turn OFF (“0” = OFF) the daylight saving function. 

3. 

Confirm with the SET key and enter the Manual Time setting

 

Important: 
This function is only significant if the time reception setting is turned OFF “0”. 
 

 

Daylight saving time setting “1” (ON): the clock calculates DST automatically in 
normal quartz mode. DST begins on the last Sunday of March and ends on the last 
Sunday of October. 

 

Daylight saving time setting “0” (OFF): DST feature is OFF and the clock will not 
change time automatically. 

If the time reception setting is turned ON “1”, please set the daylight saving time “1” 
(ON):
 the time change will be updated by the DCF-77 signal (as long as a proper reception is 
possible).  
In case of daylight saving time setting “0” (OFF): the time will be transmitted by the DCF-77 
signal, but the clock calculates automatically a “no-DST time”. 

 

MANUAL TIME SETTING: 

In case the weather station cannot detect the DCF-signal (for example due to disturbances, 
transmitting distance, etc.), the time can be manually set. The clock will then work as a 
normal quartz clock. 
 
 
 
 

 

 

1. 

The hour digit will start flashing. 

2. 

Use the + or MIN/MAX key to set the hour. Keep holding the key allows the digit to 
advance faster. 

3. 

Press again the SET key to set the minutes. The minute digits start flashing. 

4. 

Use the + or MIN/MAX key to set the minutes. Keep holding the key allows the digit to 
advance faster 

5. 

Confirm with the SET key and enter the Calendar setting.  

 

Note: 

 

The unit will still try and receive the signal despite it being manually set. When it does 
receive the signal, it will change the manually set time into the received time. During 
reception attempts the DCF tower icon will flash. If reception has been unsuccessful, 
then the DCF tower icon will not appear but reception will still be attempted the 
following day. 

 

The time reception “       “ and the “DCF” icons will not be displayed on the LCD after 
manual time setting. 

 

CALENDAR SETTING 

 
 
 

 

1. 

The year digits will start flashing. The range runs from 2011 to 2025 (default is 2011). 

2. 

Use the + or MIN/MAX key to set the year. Keep holding the key allows the value to 
advance faster. 

3. 

Press the SET key to confirm and enter the month setting mode.  

4. 

The month digit will be flashing. Use the + or MIN/MAX key to set the month. Keep 
holding the key allows the value to advance faster. 

5. 

Press the SET key to enter date setting.   

6. 

The date digit will be flashing. Use the + or MIN/MAX key to set the date. Keep holding 
the key allows the value to advance faster. 

7. 

Confirm with the SET key and exit the manual setting. 

 

Note: 
The weekday is automatically displayed above the time in short form (from Monday to 
Sunday): MO / TU / WE / TH / FR / SA / SU

TO EXIT THE MANUAL SETTING MODE 

To exit the manual setting mode anytime during the manual setting, press the ALARM key. 
The mode will return to normal time display. 

 

ALARM SETTING 
 
 
 
 

 

To set the alarm: 
1. 

Press and hold ALARM key for 3 seconds until the alarm time shown. 

2. 

The hour digit will be flashing. Use the + or MIN/MAX key to adjust the hour. Keep 
holding the key allows the value to advance faster. 

3. 

Use the ALARM key again, and the minute digits will be flashing. Press + or MIN/MAX 
key to set the minute. Keep holding the key allows the value to advance faster. 

4. 

Press the ALARM key to confirm the setting. 

 

Note:  
To activate/deactivate the alarm function, press the ALARM key once. The display of the 
alarm icon represents that the alarm is "ON". 
The duration of alarm sounding is 2 minutes. Press any key will stop the alarm sound.  

 

WEATHER FORECASTING ICONS: 

The weather icons in the second section of LCD can be displayed in any of the following 
combinations: 
 
 
 
 
 
 

      

                                 

For every sudden or significant change in the air pressure, the weather icons will update 
accordingly to represent the change in weather. If the icons do not change, then it means 
either the air pressure has not changed or the change has been too slow for the weather 
station to register. However, if the icon displayed is a sun or raining cloud, there will be no 
change of icon if the weather gets any better (with sunny icon) or worse (with rainy icon) since 
the icons are already at their extremes. 

 

The icons displayed forecasts the weather in terms of getting better or worse and not 
necessarily sunny or rainy as each icon indicates. For example, if the current weather is 
cloudy and the rainy icon is displayed, it does not mean that the product is faulty because it is 
not raining. It simply means that the air pressure has dropped and the weather is expected to 
get worse but not necessarily rainy. 

 

Note: 

 

After setting up, readings for weather forecasts should be disregarded for the next 12-24 
hours. This will allow sufficient time for the weather station to collect air pressure data at a 
constant altitude and therefore result in a more accurate forecast. 

 

Common to weather forecasting, absolute accuracy cannot be guaranteed. The weather 
forecasting feature is estimated to have an accuracy level of about 75% due to the varying 
areas the weather station has been designed for use. In areas that experience sudden 
changes in weather (for example from sunny to rain), the weather station will be more 
accurate compared to use in areas where the weather is stagnant most of the time (for 
example mostly sunny). 

 

If the weather station is moved to another location significantly higher or lower than its initial 
standing point (for example from the ground floor to the upper floors of a house), discard the 
weather forecast for the next 12-24 hours. By doing this, the weather station will not mistake 
the new location as being a possible change in air-pressure when really it is due to the slight 
change of altitude.  

 

WEATHER TENDENCY INDICATOR 

The weather tendency indicators (located on the left side of the weather icons) are working 
together with the weather icons. When the indicator points upwards, it means that the air-
pressure is increasing and the weather is expected to improve, but when indicator points 
downwards, the air-pressure is dropping and the weather is expected to become worse. 

 

Taking this into account, one can see how the weather has changed and is expected to 
change. For example, if the indicator is pointing downwards together with cloud and sun 
icons, then the last noticeable change in the weather was when it was sunny (the sun icon 
only). Therefore, the next change in the weather will be cloud with rain icons since the 
indicator is pointing downwards. 

 

Note: 

 

Once the weather tendency indicator has registered a change in air pressure, it will remain 
permanently visualized on the LCD.

 

 

AIR PRESSURE HISTORY (ELECTRONIC BAROMETER WITH BAROMETRIC 
PRESSURE TREND) 

The right side of the second section of the LCD shows the air pressure history bar graph.  
 
 
 
 
 

 
 
 

The bar graph indicates the air pressure history trend over the last 12 hours in 7 intervals: 0h,      
-3h, -6h, -9h and -12h. The “0h” represents the current full hour air pressure recording. The 
columns represent the “hPa” (0, ±1, ±3, ±5) at specific time. The “0” in the middle of this scale 
is equal to the current pressure and each change (±1, ±3, ±5) represents how high or low in 
“hPa“ the past pressure was compared to the current pressure. 
If the bars are rising it means that the weather is getting better due to the increase of air 
pressure. If the bars go down, it means the air pressure has dropped and the weather is 
expected to get worse from the present time “0h“. 

Flashing 

Air pressure trend over the 
last 12 hours 

Alarm time (flashing) 

Sunny 

Cloudy with sunny intervals 

Rainy 

Weekday

 

 

Year 

 

Date. Month.

 

Alarm indicator (ON) 

Flashing 

Hour flashing 

 

Minutes flashing 

key

MIN/MAX key

ALARM key

 

Flashing 

Flashing 

« Instant Trans» is the up and coming state-of-the-art new wireless 
transmission technology, exclusively designed and developed by LA CROSSE 
TECHNOLOGY.  
“IT +” offers you an immediate update of all your outdoor data measured from the 
transmitters: follow your climatic variations in real-time!

 

 

Weather tendency 

indicator

Indoor humidity 
display in RH%

 

Low battery indicator 

(weather station)

Weather

forecast icon

Air pressure history 
bar graph

 

Outdoor data signal  
reception indicator *

 

Low battery indicator 
(outdoor transmitter) 

 

Outdoor 

temperature 

in °C

MIN/MAX outdoor 
temperature display

 

Weekday

 

Indoor 

Temperature 

in °C 

Time

 

Alarm icon

 

 

Outdoor humidity 
display in RH%

 

Reviews: