background image

 

Operation Manual 

Professional Remote Weather Station 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
This Operation Manual is part of this product and should be kept 
in a safe place for future reference. It contains important notes 
on setup and operation. 
 
Please visit our web site 

www.heavyweather.info

 for downloads 

of complete instruction manuals and the most current version of 
the 'Heavy Weather' software. 
 

Table of Contents 
 
 

 
 
 

1. Introduction 
2. Intended use 

Weather Station 
System requirements for PC use 
Features of the base station 
Features of the thermo-hygro sensor 
Features of the wind sensor 
Features of the rain sensor 

3. Safety Notes 
4. Packaged contents 
5. Setting up 
6. Operation using cable connection or wireless 433MHz 
7. LCD overview 
8. Function test 
9.  Mounting 
10. Resetting & factory settings 
11.  Function description 
12. Operation keys 
13. Basic programming modes 
14. MIN/MAX programming modes 
15. Alarm programming modes 
16. Auto-memory for stored values 
17. Accessories: extensions cables 
18. Changing batteries 
19. Interference and problems with operation 
20.  Transmission range 
21. Cleaning and maintenance 
22.  Specifications 
 
 
 
 
 
 
 

 

WEATHER STATION 

433MHZ 

W IRELESS 

Summary of Contents for WS2307

Page 1: ...Features of the base station Features of the thermo hygro sensor Features of the wind sensor Features of the rain sensor 3 Safety Notes 4 Packaged contents 5 Setting up 6 Operation using cable connec...

Page 2: ...ther station is designed to work easily with your PC There are tedious requirements to turn your PC ON or OFF simply connect and disconnect the PC cable at any time System Requirements for PC use The...

Page 3: ...liable For reasons of safety and operation alterations to this device are strictly prohibited To operate the weather station use only supplied adaptor and batter ies of the recommended type Do not le...

Page 4: ...of the thermo hygro sensor to reveal the three sockets for the wind sensor rain sensor and the base sta tion 2 Connect the attached cables of wind and rain sensors to the corresponding sockets of the...

Page 5: ...and will result in higher power consumption Therefore batteries will have a shorter life span for cable connection compared to using 433MHz To operate using cable connection simply use the enclosed 1...

Page 6: ...door temperature and humidity 2 Outdoor temperature and humidity 3 Outdoor wind chill 4 Dew point 5 Rainfall 24 hour 6 Rainfall 1hour 7 Rainfall Total 8 Relative and absolute pressure 9 Wind speed win...

Page 7: ...ndered from all directions ideal mast size should be from 16mm 33mm Once the wind sensor is fixed onto the mast connect the cable to the corresponding thermo hygro sensor socket so that operating powe...

Page 8: ...C use please see PC user manual in the enclosed Heavy Weather CD ROM However if you wish to make a full reset of the base station and return to the original factory settings simultaneously press and h...

Page 9: ...ion will register this as a change in weather Air Pressure LCD Section 1 The air pressure reading is displayed here Press the PRESSURE key to toggle between relative and absolute air pressure displays...

Page 10: ...ection will be displayed on the LCD compass on the wind section Press the WIND key to toggle between wind direc tion as numerical e g 225 and abbreviated characters e g SW as well as numerical wind sp...

Page 11: ...nual setting mode allows the user to change several basic settings which is done by accessing one mode after the other simply by pressing the SET key After the final mode or if no key is pressed for 3...

Page 12: ...or min with time and date Rainfall 24 hours max or min with time and date Rainfall 1 hour max or min with time and date Rainfall total max only with time and date When in any of the above modes press...

Page 13: ...oggle to the indoor temperature low alarm set mode 5 Press and hold the SET key to enter the indoor temperature low setting values temperature digits will start flashing and set the desired indoor tem...

Page 14: ...will start flashing and set the desired wind chill low by using the PLUS or MINUS keys 6 Press ALARM key to confirm and press the MIN MAX key to re turn the normal display mode or press the ALARM onc...

Page 15: ...rm 2 Continue to press the ALARM key until you reach the wind direc tion alarm set mode 3 Press and hold the SET key to enter the wind direction setting values 4 Using the PLUS or MINUS keys select th...

Page 16: ...Tempera ture 30 0 C 69 9 C Indoor Temperature 9 9 C No alarm will sound if the minimum indoor temperature alarm is set below 9 9 C 59 9 C Humidity all 20 RH 95 RH Rainfall 24h 0 0 mm 1000 mm Rainfall...

Page 17: ...y in the thermo hygro sensor 1 Open the battery cover 2 Remove the old batteries and insert with new ones of the rec ommended type and replace the cover Once the sensor is powered up press and hold th...

Page 18: ...ese devices allow the change to an interference free frequency Such measures will effectively overcome interferences 20 Transmission Range The transmission distance from the thermo hygro sensor to the...

Page 19: ...seconds Indoor data Pressure temperature 4 times per minute Indoor Temperature Range 9 9 C to 59 9 C shows OFL if outside range Resolution 0 1 C Measuring Range Rel Humidity 20 to 95 if the relative...

Page 20: ...n of Conformity We hereby declare that this wireless transmission device does comply with the essential requirements of R TTE Directive 1999 5 EC EJIN23000012 For use in Germany Austria UK France Belg...

Reviews: