background image

 

 
 
 
 
 

 
 
 

 

Model WS-8120U 

Solar Wall Clock

  

 

QUICK SETUP GUIDE 

 

 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 

LCD display

Solar panels 

%

Function keys

Battery cover

 

Wall mount 
location 

Foldable stands

 

Solar-powered Transmitter: 

 

Remote transmission of outdoor 
temperature to the Solar Clock by 915 
MHz signals 

 

LCD displays outdoor temperature data 

 

Recharge batteries by solar-powered 
cells 

 

Wall mounting case 

 
 
 

 

 

Note: 

 

The solar-powered temperature transmitter uses solar cells to 
charge the rechargeable batteries (2 x AAA rechargeable batteries: 
included).  

 

Those rechargeable batteries cannot be replaced.

 

 

SOLAR TRANSMITTER OPERATION MODES 

Important:  
Users need to press the reset key to activate the solar transmitter 
and link the transmission to the Solar Station (receiver). 

 

It is important to allow sufficient light to reach the solar panel while 
activating the solar transmitter. Make sure the lights are on in the setup 
room and the solar panel is facing a 60W light bulb or brighter - 

do not 

cover with hands or other objects. 

 

Solar transmitter RESET key: 

 
 
 
 
 
 
 

 

The solar transmitter has 3 operations modes: 

 

Normal Operation Mode: 

 

This mode occurs when the battery voltage is higher than 2.5V. 

 

The transmitter will measure and transmit the temperature data to 
the solar wall clock every 8 seconds. 

 

The environment brightness is checked every 5 seconds 

 

If a dark environment is detected, it will measure and transmit the 
temperature every 16s 

Note: only use a small pointed pen to 
press the RESET key to re-active the 
transmitter into Normal Operation Mode.

 

Solar panel

 

 RESET key

 

 

If the battery voltage is dropped lower than 2.8V, it will measure and 
transmit the temperature every 16s 

 

If battery voltage is dropped lower than 2.4V, will go into Idle mode 

 

If the solar transmitter is placed into a dark environment for 72 
hours, will goes into Stop mode. 

 

If the user cover the solar cell for 10 seconds and press the reset 
button, "StP" will be displayed on the LCD. Then the transmitter 
enters STOP mode. 

 

Idle Operation Mode: 

 

This mode occurs when the battery voltage drops lower than 2.4V 

 

LCD is turned off. 

 

Does not perform temperature measurement and transmission. 

 

The environment brightness is checked every 5 seconds 

 

If battery voltage is raised higher than 2.5V, will go into Normal 
mode 

 

If the solar transmitter is placed into a dark environment for 72 
hours, will goes into Stop mode. 

 

Stop Operation Mode: 

 

This mode occurs when the solar transmitter is placed into a dark 
environment for 72 hours or the user covers the solar cell for 10 
seconds and presses the RESET button. 

 

The transmitter is in a standby state. The unit does not perform any 
operations and LCD is off. 

 

Under a bright condition, press the reset button to wake up the 
transmitter into normal operation mode (battery voltage is higher 
than 2.5V). 

 

This is the most power saving mode. 

 

TO INSTALL / REPLACE BATTERY IN THE SOLAR CLOCK 

The Solar Clock can use either the included 2 x alkaline rechargeable 
battery (charged by solar panel: included) or 2 x AA alkaline battery (non-
rechargeable; not included). 

 

INITIAL SETUP 

It is very important to 

follow these steps

  

1. 

First, remove the label covering over the battery compartment on 
the back. 

2. 

Open the battery compartment, and 

MAKE SURE

 that the battery 

switch is in the 

BATTERY

 position (not the SOLAR position).  

 

Battery switch in the BATTERY position 

 

3. 

Now locate the battery insulator tab, and gently pull to remove it. 

4. 

Slide the battery switch to the SOLAR position 

5. 

Battery switch in the SOLAR position 

 

6. 

Continue to section titled “

Setup After Changing/Installing the 

Battery in the Solar Clock 

” 

 

TO INSTALL / REPLACE BATTERY 

The included alkaline rechargeable batteries should provide you with 
many years of service. If your batteries need to be replaced, we suggest 
you use 2 fully charged the AA Alkaline. 
Rechargeable batteries should be fully charged before inserting into clock. 

Alkaline rechargeable batteries must be used.

 

  

If you choose to use non-rechargeable batteries, the battery switch MUST 
be moved to the 

BATTERY

 position (not the SOLAR position). In this 

position, the solar cells do not charge the batteries. 

  

REGARDLESS OF THE TYPE OF BATTERIES INSTALLED, THE 
BATTERY SWITCH MUST BE IN THE BATTERY POSITION WHEN 
THE BATTERIES ARE INSERTED.  

 

If rechargeable batteries are used, the Battery switch should be moved to 
the SOLAR position AFTER it is has been inserted. 

  

To use non-rechargeable alkaline batteries: 

1. 

Remove the included rechargeable AA batteries from the 
compartment. 

2. 

Use the switch to select the alkaline battery (see below). 

3. 

Insert the batteries into the compartment, observing the correct 
polarity (see marking inside battery compartment. 

4. 

Replace battery cover 

 

Note

: For best performance, batteries should be replaced at least once 

every 2 years to maintain the best running accuracy. Ensure that the 
batteries used are new and the correct size.  
 
 

 

 
 
 
 
 

 

 
 
 
 
 
 
 
 
 
 
 

Use switch to 
select which type 
of battery will be 
used before 
inserting the 
battery into the 
compartment 

Battery 
compartment 
cover 

Reviews: