background image

Hisha

USER MANUAL

Summary of Contents for Hisha

Page 1: ...Hisha USER MANUAL ...

Page 2: ...e user manual carefully You can know not only how to use but also the strong points of the product with a manual use the strong points well to select custom water for various purposes and use it effectively and moreover optimize the performance and life of the product All employees of our company promise to think in customer s shoes at all times and be dedicated to the benefits health and happines...

Page 3: ...ct Special Features Major Components Parts and Features Before installation Installation Installation checklist How to use When to change the filters How to change the filters Summary of Operation Notices Notices for Safety Product Specifications Warranty Registration Table of Contents 4 5 6 7 8 13 14 16 17 20 20 22 23 ...

Page 4: ...r pressure Semi permanent newly developed high performance ceramic valve system 4 High performance high efficiency SMPS power control system with little power loss and low heating 5 Minimized failure and maximized life by the newly developed cutting edge modularization system by part of the inner structure 6 Newly developed control system from detection and control of the amount of filter use to t...

Page 5: ... Power cable Tap water input Acidic water output Overflow output Speaker Filter cover Control buttons Tap water input Acidic water output Overflow output Filter lifespan indicator User manual Diverter valve Tubing Accessories 6x8 90 elbow connectors pH test drops ...

Page 6: ...ter Water control valve Select water type and turn the valve ON Level 1 acidic water Level 2 acidic water Purified water Cleaning Settings Filter lifespan indicator Cleaning Settings Tap to start cleaning cycle or access settings Cleaning starts automatically every 30 liters of continuous use to protect electrolysis chamber ...

Page 7: ...Keep the product in dry places avoid high moisture areas or direct sunlight Connect the ionizer only to cold water supply Damage resulting from connecting the ionizer to hot water supply is not covered by the warranty Acidic water tubing must not be raised higher than the base of the product Within 1M do not use the outlet hose to be longer than 1M ColdWater ...

Page 8: ...ilter cover Power cable Overflow output optional Tap water input Acidic water output Faucet Back open Close Lock the tap water connect the device to cold water supply The hose included with the device is 6ø 1 4 inch 1 ...

Page 9: ...cking O Shape Packing O Shape Packing Water Entrance Control Valve Elbow Product Water Entrance Hole Installation of separation cool and hot water type Nipple with a hole Nipple with a hole Switch valve of incoming water Controlling the water pressure c O Shape Packing O Shape Packing Switch valve of incoming raw water The connecting hose with product for incoming water ...

Page 10: ... to leak because the hose in the hose stop down nut can be torn Or if you stop down the nut too loose the water will leak because the hose is missed from the switch valve So you connect the hose safely by giving the proper strength carefully If you mix up the raw water inlet with the acidic water outlet alkali water will not be produced and be the cause of a failure So you must not install reverse...

Page 11: ...ionizer 3 Firmly connect water supply and drain tubing to the elbow connectors 4 CAUTION Inlet outlet check Because a confusion between the inlet of raw water and the outlet of acidic water not only prevents alkaline water from being created but also causes a severe failure of the product make sure not to install the inlet of raw water and the outlet of acidic water in the opposite way ...

Page 12: ...ow 6 Cut the acidic water hose within 1m Failure to do so may lead to the different ratio of alkaline water and acidic water and taste of water The end of the hose for acidic water output must be lower than the device Firmly installed hose goes about 1 5 cm inside the output nest Check the hose connections for leaks before using the device Open the water tap first to fully drain rust waste before ...

Page 13: ...e valve to adjust the water pressure The proper water pressure for the normal operation is 1 5 3 0kgf cm2 How to check the water pressure and set up If the quality of groundwater is bad you must mount a preprocessing filter In the area which has high solidity and calcareous there is soiled as white by the calcium so in the middle of water flow you push the acidic water button 2 3 times in the week...

Page 14: ...water and the LED light will be turned on with buzzer sound 1 2 Button for 1th level of alkaline water Button for 2th level of alkaline water Button for 3th level of alkaline water Button for 4th level of alkaline water Button for 1st level of acidic water Button for 1st level of acidic water Button for purified water Clean Set Button How to operate ...

Page 15: ...e water pressure is high Turn the On Off valve to Off side to stop the water 3 4 Filter LED will indicate the remaining filter life time before flickering the light when start to drain the water After any level of water automatically will be switched to the 2nd level of alkaline water Auto cleaning system will be run with buzzer sound to protect the electrolysis chamber when drain the 30 liters of...

Page 16: ...n though the filter purification capacity is still left On the contrary if the period is still left replace the filter if the filter purification capacity is exhausted LED for filter lifetime indication If the water quality of raw water is low install a pre filter In the event that the water flowed out smells replace the filter although it is before the filter replacement time Replace the filter i...

Page 17: ...ge the filters Lock the switch valve of incoming water Unplug the ionizer 1 2 How to change the filters Remove the filter cover pushing the hook on it Take out the old filter to be replaced by pulling it forward 3 4 ...

Page 18: ...and turn it to the right OPEN then pull out 5 6 Press 7 Please remove the safety seal of the new filter Insert the new filter bottom side first push in the turn it to the left CLOSE Make sure that the rubber ring in the connection between the filter and the main body is not detached or jammed Failure to do so may cause a leak of water ...

Page 19: ...ng sensor Please refer to above picture to be careful with electric wire when you push the filter into a position Close the filter cover Reconnect the power cord and open the action valve to drain water for 2 3 minutes until the black water is completely drained out before drinking ...

Page 20: ...yed please change the filter as soon as possible When you do not use this product for more than two days run water through it for 1 2 minutes before using When you use this product for the first time run water through it for 2 3 minutes When you do not use this product for a long time over 1 week please unplug it remove the filters and dry it out Be careful when changing the filters to not damage ...

Page 21: ...t Do not connect too many electrical plugs to one power supply Dry your hands before inserting or removing the electrical plug Do not bend or pull the electrical plug with too much strength Do not take apart or repair the KYK Product without certification To avoid problems and failures of the KYK product Do not twist or bend the water supply hose To avoid leakage Do not use thinner benzene or wax ...

Page 22: ...ring Company Manufacturing No and Date The object of Product Standard Voltage and Frequency S i z e a n d w e i g h t Composition and Water Supply Type A v a i l a b l e T e m p e r a t u r e E l e c t r o l y s i s M e t h o d L E D D i s p l a y Filter Change see the user manual 2213 Alkaline Water Ionizer Hisha KYKCo Ltd 406 410 Sun il technopia 555 Dunchon road Joongwon Gu Sungnam City Kyunggi...

Page 23: ...placetheproduct 2 Customerwill pay for repair chargesincluding shipping underthefollowingconditions 1 Amalfunctionoccurs after thewarrantyhasexpired 2 Theunitisdamagedbythecustomer 3 Damageiscausedbycustomer attemptingtorepairtheunit themselvesortheunit isrepaired byanunauthorizedservicecenter 4 Damageiscausedbyusingtheincorrect electrical voltage 5 Damageiscausedbyusinganimitation filter 6 Damage...

Reviews: