INTRODUCTION

This procedure defines the installation and wiring for the Auto 

Charge 12 PIM Automatic Battery Charger. It is suggested that 

the installer read the entire instruction manual to become 

familiar with the tasks involved before starting. 

The Auto Charge 12 PIM Battery Charger is a compact 

completely automatic charger designed for installation on 

vehicles with one (1) battery. The Auto Charge 12 provides 

complete battery. Remote sensing permits long lines between 

the charger and the batteries by compensating for the voltage 

drop in the charging wires. An ammeter provides continuous 

indication of the charger output.

Construction of the Auto Charge 12 PIM is extremely rugged 

to withstand the shock and vibration normally encountered 

by vehicle mounted equipment. The unit operates completely 

automatically and stops charging the batteries when they 

are fully charged. There is no trickle charge and therefore no 

danger of overcharging and water boil-off. Any parasitic loads 

on the battery such as radio, lights, etc., will be supplied by 

current from the charger.

Any 120 volts loads when plugged into the GFI on the Auto-

Charge 12 PIM will be protected from ground faults. A separate 

level operated circuit breaker protects the GFI connected 

loads. This circuit breaker may also be used to disconnect 

these loads from the line. The fuse on the Auto-Charge 12 PIM 

protects the charger only.

INSTALLATION

The Auto Charge 12 PIM Automatic Battery Charger should be 

installed in an area with adequate ventilation. A power cord is 

supplied for connection to 115 volts 60 Hz.

1.  Mount the charger using the four holes provided for this.

2.  Connect the wiring from the battery to the Output 

Terminal Strip. Spade lugs that have been securely 

crimped, or soldered, should be used.

3.  Double check all wiring before proceeding.

4.  Wire the A.C. power line cord to 115VAC.

5.  Pilot light will light to show that the charger has power.

6.  The ammeter will indicate how much the batteries are 

charging. A charging current limit of amperes is factory 

set.

WARRANTY

All products of Kussmaul Electronics Company Inc. are 

warranted to be free of defects of material or workmanship. 

Liability is limited to repairing or replacing at our factory, 

without charge, any material or defects which become 

apparent in normal use within 3 years from the date the 

equipment was shipped. Equipment is to be returned, shipping 

charges prepaid and will be returned, after repair, shipping 

charges paid.

Kussmaul Electronics Company, Inc. shall have no liability for 

damages of any kind to associated equipment arising from the 

installation and /or use of the Kussmaul Electronics Company, 

Inc. products. The purchaser, by the acceptance of the 

equipment, assumes all liability for any damages which may 

result from its installation, use or misuse, by the purchaser, his 

or its employees or others.

MODEL #091-12PIM  -  AUTOMATIC BATTERY CHARGER

This charger is designed for vehicles with single batteries and either negative or positive ground.

INPUT: 120 Volts A.C., 50/60 Hz, 4 Amps

OUTPUT: 13.25 Volts D.C.