BEFORE YOU BEGIN

BEFORE YOU BEGIN

·

·

·

·

·
·

·

Please read these instructions carefully to familiarize
yourself with the required tools, materials, and installation
sequences. Follow the sections that pertain to your
particular installation. This will help you avoid costly
mistakes. In addition to proper installation, read all
operating and safety instructions.
All information in these instructions is based upon the
latest product information available at the time of
publication. Kohler China. reserves the right to make
changes in product characteristics, packaging, or
availability at any time without notice.
These instructions contain important care, cleaning, and
warranty information-

Turn off the water supply.
The pluming installation must comply with Water Supply
Regulations/Bye-laws, Building Regulations or any
particular regulations and practices, specified by the local
water company or water undertakers. The installation
should be carried out by a plumber.
Before installation carefully inspect the new fixture for any
signs of damage.

please leave instructions for the

consumer.

IPSWICH bathroom cabinet adopts E1 grade wood-based
panel of high quality, and with further processing, its
harmful emissions will be less than 1.5mg/L.

·

·

·

·

·
·

·

-

E1

1.5mg/L

ORDERING INFORMATION

This installation covers the following products in the NEW
IPSWICH range:

NEW IPSWICH C Cabinet 600mm ....................K-97779T
NEW IPSWICH C Cabinet 800mm ....................K-97794T

600mm...........................K-97779T

K-97794T

800mm...........................

SAFETY: WARNINGS

Kohler products are precision-engineered and should give
continued superior and safe performance, provided:

1. They are installed, commissioned, operated and

maintained in accordance with the recommendations given
in this Manual.

2. Periodic attention is given, as necessary, to maintain the

product in good functional order. Recommended
guidelines are given in the

section.

Carefully inspect the new fixture for any signs of damage.

When installing Kohler Products, manufacturers guidelines for
power tool safety should be followed.

MAINTENANCE

1.

2.

1244199-T01-A

Summary of Contents for NEW IPSWICH C K-97794T

Page 1: ...cified by the local water company or water undertakers The installation should be carried out by a plumber Before installation carefully inspect the new fixture for any signs of damage please leave instructions for the consumer IPSWICH bathroom cabinet adopts E1 grade wood based panel of high quality and with further processing its harmful emissions will be less than 1 5mg L E1 1 5mg L ORDERING IN...

Page 2: ...tructions We suggest using P trap drain Connect P trap pipe with washbasin drain Make sure a watertight seal exisits on all washbasin drain connections Provide access to the plumbing connections for future plumbing maintenance The hot and cold water supplies must be installed with isolating valves CAUTION CAUTION NOTE A H C P Fig 2 2 Reference Value Kohler reserves the right to change marked dimen...

Page 3: ... 8 Fig 4 4 3 Dismount the washbasin cabinet and put aside Drill holes at the marked position 4 Insert the plugs into the wall 5 Apply a washer to the screw before tighten it Make sure the washbasin cabinet has been fixed firmly on the wall CAUTION NOTE Avoid the cables and pipes inner set when drilling in the wall Different types of bolts are required for different decoration boards Please apply s...

Page 4: ...6 As illustrated in Fig 5 open the flap down door and loosen the screws of the PVC basket Remove the basket upwards 7 Install handle as illustrated in Fig 6 8 Install the PVC basket as illustrated in Fig 7 7 6 8 7 4 1244199 T01 A ...

Page 5: ...nthetic top and the cabinet connect Fig 9 9 10 9 11 10 Adjust the hinge cover in 3 direction to make sure the door is level As shown in Fig 9 11 Place the hinge cover and plastic cover Fig 8 8 9 8 9 Adjust position of the adjustable shelf as shown in Fig 8 a b c d e Loosen the clip Lift the shelf to remove it Adjust position of the shelf support Press down the shelf Tighten the clip 1244199 T01 A ...

Page 6: ...into the U Notch Fig 11 11 Faucet Supply Lines Shut off Valve Drain Assembly Ripple Pipe Outlet Fig 10 10 1 P U Connect Drainage 1 Inwall drainage P Trap Please install the drain assembly and faucet as shown Please set the water supply and drainage position according to the suppliers instructions You can put the pipe into the U Notch Faucet Supply Lines Shut off Valve Drain Assembly 1244199 T01 A ...

Page 7: ... cloth Maintain ventilation in the bathroom and separate the dry area from the damp one if conditions permit Try to open the door and windows of the bathroom and maintain good ventilation Kohler bathroom cabinet are dealt with strict procedures for damp proof whose good damp proof function ensures good performance even in bathroom of huge humidity Yet do not splash and pour water directly on the b...

Reviews: