background image

Example Vent System

90º  elbow

6' (1.8 m)

2’

(0.6 m)

Wall cap

PRODUCT MODEL NUMBERS

PRODUCT DIMENSIONS

INSTALLATION CLEARANCES

VENTING REQUIREMENTS

KICU465S

Electrical:

120-volt, 60-Hz, AC-only, 15-amp,

fused electrical curcuit is required. Use copper
wire only.

36" Island Range Hood

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only.  For complete details, see Installation
Instructions packed with product.  Specifications subject to change without notice.

Ref. W10094880C

06-24-08

®

Maximum length  

=  35' (10.7 m)

1 — 90° elbow 

=  5' (1.5 m)

8' (2.4 m) straight 

=  8' (2.4 m)

1 — wall cap 

=  0' (0 m)

system length 

= 13' (3.9 m)

Note:

Flexible vent is not recommended. Flexible vent

creates back pressure and air turbulence that greatly
reduce performance. 

Vent system can terminate either through the roof or
wall. To vent through a wall, a 90° elbow is needed.

Non-vented (recirculating) installations

Vented installations

Note:

The hood chimneys are adjustable and

designed to meet varying ceiling or soffit heights
depending on the distance “X” between the bottom
of the hood and the cooking surface. For higher
ceilings, a 40” (101.6 cm) Chimney Extension Kit
Part Number 8212698 (Black), Kit Part Number
8212696 (Stainless Steel) or Kit Part Number
8212697 (White) is available. See your dealer. The
chimney extension replaces the upper chimney
shipped with the hood.

Important:

Minimum distance “X”: 24” (61.0 cm)
Suggested maximum distance 
“X”: 30” (76.2 cm)

For vented installations, the chimney can be
adjusted for ceilings between 7’ 7-1/8” 
(2.31 m) and 9’ 1-3/4” (2.79 m).

For non-vented (recirculating) installations, the
chimney can be adjusted for ceilings between 8’
3-3/8” (2.52 m) and 9’ 5-1/4” (2.88 m).

Important:

As hood height (distance X) 

increases

, hood's

venting effectiveness 

decreases

.

13

³⁄₄

"

(34.9 cm)

12

¹⁄₁₆

"

(30.6 cm)

26

³⁄₈

"

(65.1 cm)

min.

38

¹⁄₂

"

(97.8 cm)

max.

27

¹⁄₂

"

(69.9 cm)

23

⁵⁄₈

"

(60.0 cm)

3

¹⁵⁄₁₆

"

(10.0 cm)

36" (91.4 cm)

13

³⁄₄

"

(34.9 cm)

12

¹⁄₁₆

"

(30.6 cm)

32"

(81.3 cm)

min.

39"

(99.0 cm)

max.

23

⁵⁄₈

"

(60.0 cm)

3

¹⁄₂

"

(8.9 cm)

12

¹⁄₂

"

(31.8 cm)

5"

     (12.7 cm)

3

¹⁵⁄₁₆

"

(10.0 cm)

See NOTE

X

36" (91.4 cm)
Countertop
hei

g

ht

Roof Venting

Wall Venting

A. Roof cap
B. 6" (15.2 cm) round vent

A. Wall cap
B. 6" (15.2 cm) round vent

A

A

B

B

6" (15.2 cm) round

Vent piece

45° elbow

2.5'
(0.8 m) 

90° elbow

5.0'
(1.5 m)

To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the
system

.

Maximum equivalent vent length is 35' (10.7 m).

Reviews: