Example Vent System
90º elbow
6' (1.8 m)
2’
(0.6 m)
Wall cap
PRODUCT MODEL NUMBERS
PRODUCT DIMENSIONS
INSTALLATION CLEARANCES
VENTING REQUIREMENTS
KICU465S
Electrical:
120-volt, 60-Hz, AC-only, 15-amp,
fused electrical curcuit is required. Use copper
wire only.
36" Island Range Hood
Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.
Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.
Ref. W10094880C
06-24-08
®
Maximum length
= 35' (10.7 m)
1 — 90° elbow
= 5' (1.5 m)
8' (2.4 m) straight
= 8' (2.4 m)
1 — wall cap
= 0' (0 m)
system length
= 13' (3.9 m)
Note:
Flexible vent is not recommended. Flexible vent
creates back pressure and air turbulence that greatly
reduce performance.
Vent system can terminate either through the roof or
wall. To vent through a wall, a 90° elbow is needed.
Non-vented (recirculating) installations
Vented installations
Note:
The hood chimneys are adjustable and
designed to meet varying ceiling or soffit heights
depending on the distance “X” between the bottom
of the hood and the cooking surface. For higher
ceilings, a 40” (101.6 cm) Chimney Extension Kit
Part Number 8212698 (Black), Kit Part Number
8212696 (Stainless Steel) or Kit Part Number
8212697 (White) is available. See your dealer. The
chimney extension replaces the upper chimney
shipped with the hood.
Important:
■
Minimum distance “X”: 24” (61.0 cm)
Suggested maximum distance
“X”: 30” (76.2 cm)
■
For vented installations, the chimney can be
adjusted for ceilings between 7’ 7-1/8”
(2.31 m) and 9’ 1-3/4” (2.79 m).
■
For non-vented (recirculating) installations, the
chimney can be adjusted for ceilings between 8’
3-3/8” (2.52 m) and 9’ 5-1/4” (2.88 m).
Important:
As hood height (distance X)
increases
, hood's
venting effectiveness
decreases
.
13
³⁄₄
"
(34.9 cm)
12
¹⁄₁₆
"
(30.6 cm)
26
³⁄₈
"
(65.1 cm)
min.
38
¹⁄₂
"
(97.8 cm)
max.
27
¹⁄₂
"
(69.9 cm)
23
⁵⁄₈
"
(60.0 cm)
3
¹⁵⁄₁₆
"
(10.0 cm)
36" (91.4 cm)
13
³⁄₄
"
(34.9 cm)
12
¹⁄₁₆
"
(30.6 cm)
32"
(81.3 cm)
min.
39"
(99.0 cm)
max.
23
⁵⁄₈
"
(60.0 cm)
3
¹⁄₂
"
(8.9 cm)
12
¹⁄₂
"
(31.8 cm)
5"
(12.7 cm)
3
¹⁵⁄₁₆
"
(10.0 cm)
See NOTE
X
36" (91.4 cm)
Countertop
hei
g
ht
Roof Venting
Wall Venting
A. Roof cap
B. 6" (15.2 cm) round vent
A. Wall cap
B. 6" (15.2 cm) round vent
A
A
B
B
6" (15.2 cm) round
Vent piece
45° elbow
2.5'
(0.8 m)
90° elbow
5.0'
(1.5 m)
To calculate the length of the system you need, add the
equivalent feet (meters) for each vent piece used in the
system
.
Maximum equivalent vent length is 35' (10.7 m).