background image

WARMING

OVERALL

RECESSED

RECESSED

DRAWER

WIDTH (A)

WIDTH (B)

HEIGHT (C)

SIZE

24"

23

³⁄₄

"

22

¹⁄₄

"

9"

(61 cm)

(60.3 cm)

(56.5 cm)

(22.9 cm)

27"

26

³⁄₄

"

25

¹⁄₄

"

9"

(68.6 cm)

(67.9 cm)

(64.1 cm)

(22.9 cm)

30"

29

³⁄₄

"

28

¹⁄₄

"

9"

(76.2 cm)

(75.6 cm)

(71.8 cm)

(22.9 cm)

PRODUCT MODEL SERIES

PRODUCT DIMENSIONS

CABINET OPENING DIMENSIONS

A 120 volt, 60 Hz., AC only, 15-amp fused, electrical circuit is required. A

time-delay fuse or circuit breaker is also recommended. It is recommended

that a separate circuit serving only this warming drawer be provided.

Because Whirlpool Corporation policy includes a continuous commitment to improve
our products, we reserve the right to change materials and specifications without notice.

Dimensions are for planning purposes only. For complete details, see Installation
Instructions packed with product. Specifications subject to change without notice.

Ref. W10600304A

9/11/13

24" (61 CM), 27" (68.6 CM), AND 30" (76.2 CM)
INDOOR/OUTDOOR ELECTRIC WARMING DRAWER

A

B

C

ELECTRICAL CONNECTION

LOCATION REQUIREMENTS

IMPORTANT:

Observe all governing codes and ordinances.

● 

Cutout dimensions that are shown must be used. Given dimensions

provide minimum clearance with warming drawer.

● 

Recessed installation area must provide complete enclosure around the

recessed portion of the warming drawer.

● 

Grounded electrical supply is required. See “Electrical Requirements”

section.

● 

Electrical supply outlet should be located in the rear wall on the upper

right-hand side of the cutout or in an adjacent cabinet. The outlet must be

recessed. If the electrical outlet is located in an adjacent cabinet, a 1

³⁄₈

"

(3.5 cm) minimum diameter hole should have been drilled in the back of

the cutout or support surface to pass the power supply cord through to

the outlet.

● 

Warming drawer support surface must be solid, level and flush with

bottom of cabinet cutout.

● 

Warming drawers with oiled bronze, black glass, and white glass panels

are approved for indoor use only.

For best performance results make sure the warming drawer is leveled

before completing installation. There is no way to level the warming drawer

after it has been installed. If the installation is not level, the door may slide

open or not seal tightly, allowing heat to escape.
NOTE: If installing the warming drawer below another product,
refer to that product’s literature for any installation requirements.

Warming
drawer
front

Support surface must be
solid, level, flush with
bottom of cabinet cutout.

22

³⁄₄

"

(57.8 cm)
recessed

oven depth

24"

(61 cm)

min. cutout

depth

Cabinet Side View

Cabinet Front View

2

¹

/

" (6.4 cm) min.

2

¹

/

" (6.4 cm) min.

9

¹

/

" (23.2 cm)

4" (10.2 cm)

B

Recommended 4

¹

/

" (10.8 cm)

Minimum 1" (2.5 cm)

A

9

¹

/

" (23.2 cm)

Toe
kick

Warming
drawer
cutouts

120 volt
grounded
outlet
(or located
in adjacent
cabinet)

WARMING

CUTOUT

MIN. CABINET

DRAWER SIZE

WIDTH (A)

WIDTH (B)

24" (61 cm) 

22

¹⁄₂

" (57.1 cm) 

24" (61 cm)

27" (68.6 cm) 

25

¹⁄₂

" (64.8 cm) 

27" (68.6 cm)

30" (76.2 cm) 

28

¹⁄₂

" (72.4 cm) 

30" (76.2 cm)

Warming drawer can be installed as an indoor single or double installation or

installed under a single oven. Two warming drawers under a single oven are

shown.

NOTE: 

The warming drawer cannot be leveled after being installed.

For outdoor installation follow the cutout dimensions above. Install the outdoor

warming drawer in a permanent fixture.

Custom Wood Drawer Front

If you plan to install a custom wood panel to match your cabinets, we

recommend consulting a qualified cabinetmaker or carpenter. The back of the

wood panel must be sealed to avoid moisture damage.

KEWS105B
KEWS105S

KEWS145S
KEWS175B

KEWS175S

Reviews: