background image

+-++

Container and Asset GPS Tracker

MT12

User manual

Summary of Contents for MT12

Page 1: ... Container and Asset GPS Tracker MT12 User manual ...

Page 2: ...t will be added to the new version of this manual KINGWO will improve or update the products or procedures described in the manual at any time If there is a description of the product in the manual that does not match the actual product the actual product shall prevail KINGWO has the final interpretation rights of this manual ...

Page 3: ...nd zone compensation 7 3 1 9 E Sim 7 3 2 Extention Optional Functions 8 3 2 1 Light Sensor for removal alarm 8 4 Installation guide 9 4 1 Installation diagram 9 4 2 Installation and debugging 10 4 2 1 SIM card installation 错误 未定义书签 4 2 2Main Unit power on 错误 未定义书签 4 2 3 Parameter setting 错误 未定义书签 4 3 Key parameter setting 11 4 3 1 Upload in sleep mode 错误 未定义书签 4 3 2 Track mode 错误 未定义书签 4 3 3 Posit...

Page 4: ...one packet per 24 hours it would work about 3 5 years this battery is capable of support different battery capacity to meet different requirements from customers Low power consumption The working voltage is less than10μA during sleep mode to make sure the unit works longer The device supports 4G 3G 2g networks that covers most bands of the world Wireless easy to install waterproof Support E Sim wi...

Page 5: ...ge working current 100mA Sleep current 20uA Communication 4G network TDD LTE FDD LTE 3G network WCDMA 2G network GSM GPRS GSM 850 900 1800 1900MHZ GNSS Support GPS BD Dual mode GPS L1 1575 42MHz C A Code BD B1 1561 098MHz Dimension 205mm 68mm 27mm L W H Weight 200g 5g Waterproof IP67 Double waterproof function Working Temperature 20 70 PART 02 Technical Specification ...

Page 6: ... 3 LBS The default position mode is by GPS when GPS enters into the GPS blind zone and no GPS signal the device will switch to LBS LBS provides the reference location which is not very accurate as GPS 3 1 4 Battery Level Detect The device will upload the battery level status together with the location data pack and display the battery level on the backend so the user could well know the balance of...

Page 7: ...nd this function could use SMS command or backend command to set 3 1 7 Backend Specific OTA Commands from server Normally the wake up time of the device is short and SMS might not be able to received it is more reliable to send a OTA command from the server to configure the unit when the device is connected to the server the command will be immediately sent to the server and executed 3 1 8 Blind z...

Page 8: ...ions 3 2 1 Light Sensor for removal alarm Built in high sensitive light sensor module once the unit sense a light change from dark it is considered the removal alarm been triggered 4 1 Installation diagram PART 04 Installation guide ...

Page 9: ...8 Battery Switch SIM card slot Red LED Fast blink GPRS connecting Slow Blink GPRS Connected Solid on Module Light sensor E SIM Green LED Solid on GPS fixed Blink LBS Off GPS not fixed Screw Hole ...

Page 10: ...evice is with built in E SIM no need to insert SIM card 4 2 2Main Unit power on After installing the SIM card turn the battery switch to the ON position When the red light starts to flash indicating that the device is powered on 4 2 3 Parameter setting TCP UDP connection mode setting For example the client s server IP is 119 23 233 52 port number 6000 If it is connected by TCP use SMS to edit IP 1...

Page 11: ...of the device will reduce 4 3 2 Track mode Command format ZZ A T1 T2 Description track mode A A 1 Enter track mode A 0 Exit track mode T1 Set upload interval in track mode Unit Seconds T2 Set the continue tracking upload interval unit minutes ZZ 1 30 60 enter track model upload interval is 30 seconds enter sleep mode after 60 minutes ZZ 0 Exit track mode 4 3 3 Position mode Command format LBS A De...

Page 12: ... upload data frequently 4 4 Common SMS command list HX T Upload Interval in Sleep Mode default 1440 minutes as 24hours T wake up time unit minutes value range 5 43200 minutes For example HX 120 set the wake up time is 120 minutes ZZ A T1 T2 Track Mode A A 1 Enter track mode A 0 Exit track mode T1 Set upload interval in track mode Unit second value range 5 300 seconds T2 Set the continue tracking u...

Page 13: ...tatus 22 1 device restore to factory 22 4 Restart device 77 0 number Set center number 1 For example 77 0123456 center number 1 123456 77 0 delete center number 1 77 2 number Set center number 2 For example 77 2123456 center number 2 123456 77 2 delete center number 2 APN apn user pswd Set APN user name password For example APN APNAPDemo com attz internet internet APN APNAPDemo com attz Username i...

Page 14: ...e Requirements The users are required to strict using the device according to the operating instructions any disassemble collide charge soak over 80 C human failure force majeure damage etc may cause short circuit insufficient working time battery deformation liquid leakage explosion no warranty and compensation will be provided by Kingwo ...

Page 15: ...d Contact us 86 0755 86704262 marketing kingwoiot com www itracksense com www kingwoiot com Room 301 302 3rd Floor Comprehensive Building Tsinghua Information Hi tech Park North Science Park Nanshan District Shenzhen China 518052 ...