background image

                                                           

 

 

 

GSM House Alarm System 

S100

   

User Manual 

Ver 1.20    Date Issued: 2010-05-14 

All rights reserved by King Pigeon Hi-Tech. Co., Ltd. 

Website: 

Http://www.GSMalarmsystem.com

     

Summary of Contents for S100

Page 1: ...GSM House Alarm System S100 User Manual Ver 1 20 Date Issued 2010 05 14 All rights reserved by King Pigeon Hi Tech Co Ltd Website Http www GSMalarmsystem com ...

Page 2: ...012 Table of Contents 1 Brief introduction 2 2 Safety Directions 2 3 Standard Packing list 3 4 Physical Layout 3 5 Features 5 6 Settings 7 7 Operating Instructions 17 8 Installation 20 9 Add wireless sensors 24 10 Technical specifications 26 11 Important information 27 12 Maintenance 27 13 Quality Warranty 28 14 Trouble Shooting Guide 28 ...

Page 3: ... GSM Alarm System S100 with user friendly design idea all operations and settings are visual and intuitive What you need is a SIMCard which supports Call ID function 2 Safety Directions Safe Startup Do not use GSM Alarm System when using GSM equipment is prohibited or might bring disturbance or danger Interference All wireless equipment might interfere network signals of GSM Alarm System and influ...

Page 4: ...dry places and keep it dry 3 Standard Packing List Control Unit X1 Wireless Magnetic Door Sensor X1 Wireless Remote Controls X 2 Wireless PIR Motion Sensor X1 Wired Mini Siren 110dB X1 Regulated 12VDC Power Supply X1 User Manual X1 GSM Antenna X1 Optional Accessories Wireless Sensors only PIR Motion Sensor Glass Break Sensor Magnetic Window Sensor Magnetic Steel Scrolling Door Sensor Temperature S...

Page 5: ...ention to it Interface Description PIN 1 Independent Output Relay Can switch on or off by SMS Commands Rated Voltage 3A 250VAC this relay is very useful to switch on light when you can not come back in the evening Then some hours you can switch off it PIN2 Link Output Relay when the system alarm will close 4minutes Rated Voltage 3A 250VAC this relay can connect to any other lights or CCTV system a...

Page 6: ...wiretap are available 2 LCD displays the entire setup menu 3 Armed Partial Armed At House or Stay Disarmed SOS are available 4 Armed delay alarm delay siren work or not more other functions are Programmable by user 5 Watchdog 24Hours Zone SOS zone are available 6 Using ICON to display armed Partial Armed Disarmed Power status Siren status and GSM Signal status 7 Auto detect and report GSM Signal J...

Page 7: ...ne attribute Normal At House or Stay mode and Zone Name is editable 6 3 X 24 Hour zones for smoke and gas leakage sensor 1XWatchdog zone for monitoring elder or child 1XSOS zone for emergency help 7 Supports 3 SMS Alert Numbers and 5 Calling alert numbers and 20 Alarm Records for owner review 8 Supports Timer for automatically arm or disarm the system 9 Supports armed delay to give enough time to ...

Page 8: ...e will auto detect and display the process If it with SIMCard it will register the GSM Network and display the GSM Signal ICON in the left corner of the LCD 4 All of the setup can be done by the LCD except modify the Zone name if you need to modify the zone name please see the command list in the related chapter 5 Only disarm by keyboard and modify settings requires password the other operation ne...

Page 9: ...r phone is far from the S100 at least 500meters Otherwise the near cross will make lots of noise interference 6 1 Key Function Descriptions 6 1 1 Led indicator Description The S100 uses the icons to descript the function it will be more user friendly to user Alarm link output indicator when alarm will turn on and last 4minutes means the alarm link output relay closing GSM Module indicator register...

Page 10: ...1 3 Keyboard functions The S100 uses the icons to mark the buttons it will be more user friendly to user Disarm Exit and Backspace button Arm Stay and Up towards button SOS Down towards button Enter button Turn Left Right button in special menu need it to choose the option Independent output relay indicator when the independent output relay closed it will be on when the independent output relay op...

Page 11: ...the wireless sensor can transmit wireless signal 6 2 2 Setup 1 View 2 Setup 1 Alarm Records 2 Timers 3 RF Zone Name 4 SMS Phone No 5 Auto dial No 6 Report Time 7 RF Code Query To check the alarm records up to 20 event records will be saved To check the Timer you have setup To check the SMS Alert Contents of the Related Zones and its attributes To check the SMS Alert Numbers To check the Auto dial ...

Page 12: ...t alarm if the sensor hasn t been triggered will make alarm SOS Help In any mode the sensors with this type triggered will alarm but not drive the siren Alarm Action when Alarm occurrence the system will Automatically dial the Pre set Auto Dial Tel Numbers for 3 times one by one and Send SMS to the Pre set SMS Alert Numbers in the meantime will drive the siren for 60seconds and close the 1 Add Del...

Page 13: ...e one 3 In the Edit RF Parts you can edit the attribute of the sensor as Normal or Stay Type If the system is under Stay Mode Also said At House or Partial Armed the sensor set as Normal triggered will not alarm the sensor set as Stay triggered will Alarm If the system is under Armed Mode then all RF sensors triggered will alarm This is very important to remember the sensor types of the system Thi...

Page 14: ...once the sensor in these zones triggered will alarm immediately 13 Gas Leakage Alarm 14 Smoke Fire Alarm 15 Watchdog alarm Watchdog Zone the attribute can not be modified In arm or disarm or stay mode once the sensor in this zone triggered in the preset time will not alarm if the sensor hasn t been triggered in the preset time will alarm 16 SOS Help SOS zone The attribute can not be modified In ar...

Page 15: ...00 if nobody answer the calling then can not wiretap the system site if somebody answers the calling then can create two way voice communication 1 SMS Phone No 2 Auto dial Tel No 3 Time Date 4 Sound Alarm 5 Report Time Gap 6 Power Failure Alert 7 Arm Delay Time 8 Alarm delay Time To setup the SMS Alert Number must be cell phone numbers total 3 To setup the Auto dial telephone number total is 5 To ...

Page 16: ...Stay Mode 6 2 2 3 Advanced Setting For example In China the country code is 0086 please note do not write 86 The user cell phone number is 13570810254 and has been assigned as a SMS Alert number the simcard number in the panel is 13512345678 Problem 1 Alarm but the user hasn t received the SMS Alert Solution Please plus the country code while you setup the 13570810254 as SMS Alert number means set...

Page 17: ...tion when the GSM Signal is 0 for more than 90s the system will drive the siren for 60seconds and the link output relay will close 4 minutes 6 3 Modify the SMS Alert Content of the Zone Zone or Sensor Name The S100 accept SMS Command to modify the SMS Alert Content of the zone The format is Password M Zone Serial Number New Zone Name the Max Character for the zone name is 32 The Zone Serial Number...

Page 18: ...f the independent output relay by SMS Commands 7 1 Arm or Disarm or Stay Partial Arm At House Arm and Emergency Alarm by remote controls Press the button on the remote control or Press Arm button on the keyboard then select Arm the Control Unit enters arm status delay time according to the setting the ICON will be on Under this status any sensor triggered the control unit will alarm if answered th...

Page 19: ...S on the remote control or the control unit or Press any Emergency button The Control Unit will enter emergency alarm The siren will not sound but will alert the pre set phone number immediately 7 2 SMS Commands for Arm or Disarm or Inquiry system status or switch on off independent output relay The User can Arm Disarm Inquriysystem status Switch on or off the independent output relay by sending S...

Page 20: ...eturn SMS Armed or At House or Disarmed AC Power is Ok or AC Power is failed GSM Value is 17 or other value Output Relay is Closed or Output Relay is opened Example 1111DD When the Password is 1111 xxxxDD xxxx stands for the password 1 4 digits Return SMS Output Relay Opened Example 1111CC When the Password is 1111 xxxxCC xxxx stands for the password 1 4 digits Return SMS Output Relay Closed Examp...

Page 21: ...ease help to test the system firstly including wireless sensor power supply gsm signal etc Please ensure the wireless sensors and electricity appliances from the mainframe more than 3 5m 8 1 Insert SIM into Control Unit and install the GSM ANT In the backside of the control unit please install the GSM SIM card The GSM ANT must be Vertical installation to ensure it in good working condition 8 2 Ins...

Page 22: ...balcony boundary wall e t c Wireless glass break sensor can also be used see below For a Scrolling Steel Door a special Wireless Scroll Steel Door magnetic sensor must be used due to interference of the wireless signal caused by the steel door Installation attach the larger half to the floor and attach rivet or glue the smaller half to the scroll steel door An alarm is triggered when the halves ar...

Page 23: ... sensor will detect a person since human temperature is different to ambient temperature When triggered the PIR will signal the Control Unit Apply the detection area illustration below when installing Wireless curtain sensor detection area illustration below 8 4 Install other sensors For smoke you can use wireless smoke sensor for gas leakage detection you can install gas leakage sensor below ...

Page 24: ...he Siren to the Control Unit and fix them in appropriate locations Strobe Siren Siren Light Siren 8 7 Install output relays The S100 with two output relays one is for SMS Control another is for alarm output Please select the one you required The SMS control output relay is useful while you re not at house then you can send SMS to switch on the light and then switch it off if you need This action w...

Page 25: ... Unit Notice Some wireless sensors must be coded by manual as below 9 1 step some wireless sensors needn t coded by manual because of we will use the learning code sensor The learning code wireless sensor you can omit the 9 1 step can be learned to the system directly like the PIR 100B and DM 100A The Wireless sensors in the package box are pre coded prior to shipping The Max Quantity of RF sensor...

Page 26: ...will treat them as the same one sensor 4 Also please check the Resistors value is 3 3M Ohm there re 3 Jumpers 1 5M 3 3M and 4 7M if you select incorrect value the wireless distance usually very short or can not learn to the alarm panel 9 2 Enter the RF Sensor Adding Menu See 6 2 2 1 Add Del RF Parts Select the Zone number press Ok finished it then press OK to select the Normal Type Or Stay Type th...

Page 27: ...r Key on the Keyboard The system will ask you repeat the operation so please trigger Remote Control again when you see the Code then press the Enter Button on the Keyboard the system will display Saved OK It means the Remote Control added to the system Repeat this operation to add other remote controls Notice 1 VVVV means this serial position saved one remote control already you can learn a new re...

Page 28: ...2 Do not install the system in close vicinity with objects that generate strong interference such as TV set and computer 3 Install the system in a hidden place 4 Avoid getting water into the Control Unit 5 Have a secure connection to the main power supply 6 This product was designed for the indoor use 7 Opening the control unit cover will avoid the warranty 8 More information will be available of ...

Page 29: ...rs 14 Trouble Shooting Guide PROBLEM CAUSE POSSIBLE SOLUTION GSM Module initialization failed 1 Backup battery with low voltage GSM Module connection loose in transportation 2 GSM Signal is too weak 1 Please contact the AC Power 2 Please help to take the panel to a mobile phone repairmen store and then ask the engineer to check the GSM Module socket and the GSM Module connection 3 Please change an...

Page 30: ...ones or Watchdog zone 1 Please see the PIR Motion sensor installation user manual carefully 2 Please check if any sensor assigned to these special zones and made incorrect activated Alarm without SMS Alarm without Dial No action after send SMS command 1 GSM Operator communication protocol 2 Haven t setup SMS Alert Auto dial Numbers 3 Caps Lock letters in the SMS Commands 1 Please setup the SMS Ale...