background image

Thank you for purchasing your new 

StaticVac®

film cleaning machine. It will

provide years of effective operation if three simple maintenance procedures are
followed.

Begin by connecting the cord from the transformer to the machine and plugging
the machine into a GROUNDED (three wire) outlet. If an extension cord is
necessary be sure to use a GROUNDED type. Failure to properly ground your
machine may result in damage to the machine or other electronic equipment.

Place the 

StaticVac

as close as possible to the printer or projection gate for the

best performance. You will find eight (8) small magnets located in the plastic
bag Each magnet has foam
adhesive tape for mounting
to your printer. Use four (4)
for mounting if printing front
to back and four (4) for
mounting if you are printing
left to right or right to left.

The on/off switch is located
on top of the machine and
when pressed “red” will
show on the switch and the
“green” LED indicator will
light. The machine can be
run continuously during
normal operation and need
not be turned off when not
in use.

STATICVAC FILM CLEANER MODEL SV-4400U

TROUBLE CHECKS

INSTRUCTION SHEET

E

N

G

L

I

S

H

E
N
G
L

I

S
H

REMEMBER, TO ENSURE PROPER

PERFORMANCE, CLEAN EMITTERS,

BRUSHES AND FILTER REGULARLY.

It will save time and money. If service should be necessary, call, write or fax
Kinetronics Service Department.

SYMPTOM:

No power (green light won’t come on).

REMEDY: Check to see if the unit is plugged into a properly
grounded outlet. Check if on/off switch is on. Check
connecting cord.

SYMPTOM:

Film does not pull easily through machine or “catches.”

REMEDY: Check brush tension. Adjust the brushes by
loosening the SS screws on each side of the brushes. Film
should pass smoothly with a light tension.

SYMPTOM:

Film has “dust spots” remaining after cleaning.

REMEDIES:

a) With the machine unplugged, open the lid and check for
accumulated dust in brushes. Vacuum thoroughly. Brushes may
also be washed in mild shampoo and water.

b) With the machine unplugged, open the lid, check to see that
the emitter pins are free of dust. Clean with a cotton swab.

c) Check the filter. If dirty, replace or clean.

d) Check brush tension. (You may wish to remove and
shampoo brushes with gentle baby shampoo, rinse carefully,
comb brush hair straight and let AIR DRY.)

SYMPTOM:

Fan/blower stops or won’t run.

REMEDY: With the machine unplugged, check that there are no
obstacles caught in the fan.

If your machine has some other problem or the above remedies don’t work,
service help is available at 

1-800-624-3204

(in U.S. and Canada) or

941-951-2432, FAX 941.955.5992,

or contact your local Dealer or

Distributor.

Part No. 405.1E

Reviews: