background image

Manual P/N 820-1527 Rev. C 08/11

ATTENTION: Please take a few minutes to thoroughly read this

user’s guide which should be saved for future reference and

passed on to any subsequent owner.

Carbon Monoxide Alarm

User’s Guide

900-0233

and 

900-0230

900-0233

900-0230

SINGLE STATION CARBON

MONOXIDE ALARM

KN-COB-B-LS-CA

with Digital Display

KN-COPP-B-LS-CA

AA Battery Operated

Summary of Contents for 900-023

Page 1: ...d this user s guide which should be saved for future reference and passed on to any subsequent owner Carbon Monoxide Alarm User s Guide 900 0233 and 900 0230 900 0233 900 0230 SINGLE STATION CARBON MO...

Page 2: ...2 Call your emergency services Fire Department or 911 Never restart the source of a CO problem until it has been corrected Never ignore the sound of the alarm If the alarm is sounding pressing the tes...

Page 3: ...ke alarm is alarming in a non emergency situation Because your sense of sight smell hearing and touch give you information you can almost instantly judge what action to take if you hear your smoke ala...

Page 4: ...It may not fully safeguard individuals with specific medical conditions If in doubt consult a medical practitioner Individuals with medical problems may consider using warning devices which provide a...

Page 5: ...CO poisoning indicate that while victims are aware they are not well they become so disoriented they are unable to save themselves by either exiting the building or calling for assistance Also young...

Page 6: ...When the Alarm Sounds inside front cover Low Levels Generally below 50 PPM Kidde recommends you take action to eliminate the source of CO See What to do When the Alarm Sounds inside front cover IMPORT...

Page 7: ...oose from clothes dryers furnaces or water heaters Obstructions in or unconventional vent pipe designs which can amplify the above situations Extended operation of unvented fuel burning devices range...

Page 8: ...tional life You must test your CO alarm weekly because it could fail to operate at any time If your CO alarm fails to test properly or if its self diagnostic test reveals a malfunction immediately hav...

Page 9: ...ower up this alarm will beep two times every 30 seconds to indicate that it is time to replace the alarm Replace the alarm immediately It will not detect CO in this condition To help identify the date...

Page 10: ...m at eye level allows for optimum monitoring of the digital display 3 Installation Locations Recommended Locations Temperature Operating Range 4 4 C 40 F to 37 8 C 100 F Humidity Operating range 10 95...

Page 11: ...ing or cooking appliances Kidde recommends 15 ft to prevent nuisance alarms Do not install near vents flues chimneys or any forced unforced air ventilation openings Do not install near ceiling fans do...

Page 12: ...lacing the batteries use one of the following approved brands Duracell MN1500 or MX1500 Energizer E91 Gold Peak 15A Golden Power GLR6A These batteries can be purchased where you bought the alarm or at...

Page 13: ...il the screw heads are protruding approximately 1 8 from the wall If mounting in a plasterboard or drywall drill a 3 16 hole in the wall and use the plastic anchors provided 3 Hook the CO alarm over t...

Page 14: ...error condition Error Red LED constantly on Constant alarm Very low battery or unit malfunction Replace battery If condition continues unit has malfunctioned Replace immediately Unit will not respond...

Page 15: ...nly Steady 0 displayed dot flashing every 5 seconds Green LED flashes every 30 secs None Normal DC operation with good batteries sensing no CO None Lb flashes alternately with any number Red LED flash...

Page 16: ...may start out as low level leaks but could develop into CO concentrations that may become harmful If this happens the CO alarm will detect the dangerous level and alarm notifying you and others of the...

Page 17: ...or for CO Note You do not need to press the Test button to take a CO reading Maintenance Tips To keep your alarm in good working order you must follow these steps Test the alarm once a week by pressin...

Page 18: ...or loss of use of this product or for any indirect special incidental or consequential damages or costs or expenses incurred by the consumer or any other user of this product whether due to a breach o...

Page 19: ...for a particular purpose are limited in duration to the above warranty period In no event shall the Manufacturer be liable for loss of use of this product or for any indirect special incidental or con...