background image

Quick Guide and 

Schematics

Содержание 244 CC BLUEWATER

Страница 1: ...Quick Guide and Schematics...

Страница 2: ...re operating your boat safely and within the rules at all times Like all Key West Boats the 244CC was designed to be low maintenance ergonomic and an efficient boat to maintain and operate Familiarizi...

Страница 3: ...ed of in an approved waste collection device when servicing replacing The filter s must be filled with fuel after servicing replacing them in order to prime the engine A primer bulb for each engine is...

Страница 4: ......

Страница 5: ...accessory port on the port livewell pump lower hose connection on the livewell pump Using the raw water washdown does not require the port livewell pump to be on however the port seacock must be open...

Страница 6: ...s not fully open Open Valve Fully Hose s are damaged and are either leaking and or sucking air Check hoses Low Voltage to Pump s Check connections for loose or corroded wiring Check battery voltage Pu...

Страница 7: ...y debris that could damage the pump The strainer should be checked periodically and features a clear cap for easy inspection If any debris is found remove the strainer screen by untwisting the clear c...

Страница 8: ...ck battery voltage Damaged or defective pump Replace pump The Fresh Water washdown pump continues to run even after faucet is closed Intake hose from the tank to the pump is damaged causing the pump t...

Страница 9: ......

Страница 10: ...to port thru hull near transom See Note B below Console Recess Drain Gravity drain drains directly to the bilge Port Cockpit Drain Gravity drain to inboard port 1 1 2 Thru Hull Starboard Cockpit Drain...

Страница 11: ......

Страница 12: ......

Страница 13: ...s in your boats interior use a sufficient quantity of water to dilute the chemical s when spraying off so that they do not affect the foam ball when draining out The seal ring needs to be kept free of...

Страница 14: ...tive Replace Pump The Pump is defective Replace Pump Bilge pump s will not run when the manual switch on the helm is engaged Circuit breaker below the pump s switch is tripped Reset circuit breaker Th...

Страница 15: ...r house systems that can be used to parallel start one or both engines 12V power is distributed to the 12V factory installed systems through individual circuit breakers located beneath their respectiv...

Страница 16: ...l circuit switches and have 4 positions OFF 1 2 Both Top Battery Switch The top battery switch provides power to the port engine and 12V house systems If position 1 is selected on the switch the port...

Страница 17: ...minimize corrosion Key West recommends that all connections and terminals be checked at least twice a year and sprayed with a corrosion inhibiting spray at least once a year to protect and maintain t...