background image

All rights reserved. No part of this publication may be reproduced without the written authorisation of the manufacturer

KASTEL s.r.l.

 - Via Fusina, 1/A - 31033

Castelfranco Veneto - Treviso - Italy

AUTOMATIC ICE MAKER

USER MANUAL

I

GB

Summary of Contents for KP 21/5

Page 1: ...eserved No part of this publication may be reproduced without the written authorisation of the manufacturer KASTEL s r l Via Fusina 1 A 31033 Castelfranco Veneto Treviso Italy AUTOMATIC ICE MAKER USER...

Page 2: ...ON Page 8 Casing Page 8 Water system Page 10 Refrigerating system Page 12 5 ATTACHMENTS Page 14 Instructions booklet Page 14 Ice level thermostat adjustment diagram Page 23 Evaporator thermostat adjus...

Page 3: ...right temperature the freezing cycle timer starts off At the set time the water pump stops and the water load to top up the tank and cycle reversal solenoid valves are opened Heat is pumped to the eva...

Page 4: ...10 A R404A 24 230V 50Hz 530 30 10 W R404A 24 230V 50Hz 530 KP 44 15 44 15 A R404A 36 230V 50Hz 700 44 15 W R404A 36 230V 50Hz 700 KP 50 26 50 26 A R404A 36 230V 50Hz 800 50 26 W R404A 36 230V 50Hz 80...

Page 5: ...360 450 585 0 10 35 38 KP28 7 605 38 710 0 18 42 KP30 10 685 40 790 0 2 44 KP44 15 685 52 820 0 31 57 KP50 26 795 55 930 0 35 61 KP75 40 915 72 1050 0 58 80 KP100 60 1015 87 1150 0 64 96 KP130 75 108...

Page 6: ...pump eventually change it Obstructed suntion filter of the pump Check and clean the filter Faulty or obstructed water inlet valve First clean the valve eventually change it Faulty timer it doesn t ope...

Page 7: ...charge the refrigerant The ice cubes are not complete See also decreasing of production High ambient temperature and or small air circulation Change place of installation of the ice maker or change am...

Page 8: ...8 4 PARTS SECTION ENGLISH BODY...

Page 9: ...624 K01626 K01629 6 Door K00828 K00816 K00816 K00241 K00241 K00245 K00245 K00249 K00249 K00456 7 Front panel K00830 K00811 K00811 K00182 K00165 K00136 K00194 K00063 K00214 K00455 8 Back grid K00844 K0...

Page 10: ...00653 K00653 K00556 K00556 K00227 K00227 5 Flag K00008 K00008 K00008 K00008 K00008 K00008 K00008 K00008 K00008 K00008 K00008 6 Pawl K00013 K00013 K00013 K00013 K00013 K00013 K00013 K00013 K00013 K0001...

Page 11: ...nut K01126 K01126 K01126 K01126 K01126 K01126 K01126 K01126 K01126 K01126 K01126 25 Overflow pipe K00541 K00542 K00543 K00540 K00544 K00545 K00545 26 Drain screw nut K00004 K00004 K00004 K00004 K0000...

Page 12: ...12 ENGLISH COOLING SYSTEM...

Page 13: ...K00808 K00808 K00808 K00119 K00119 K00119 K00049 K00049 K00049 K00049 9 On off switch K00082 K00082 K00082 K00082 K00082 K00082 K00082 K00082 K00082 K00082 10 Timer K00075 K00075 K00075 K00075 K00075...

Page 14: ...14 5 ATTACHMENTS ENGLISH USER MANUAL...

Page 15: ...15 ENGLISH USER MANUAL...

Page 16: ...16 ENGLISH USER MANUAL...

Page 17: ...17 ENGLISH USER MANUAL...

Page 18: ...18 ENGLISH USER MANUAL...

Page 19: ...19 ENGLISH USER MANUAL...

Page 20: ...20 ENGLISH USER MANUAL...

Page 21: ...21 ENGLISH USER MANUAL...

Page 22: ...22 ENGLISH USER MANUAL...

Page 23: ...23 ENGLISH BIN THERMOSTAT REGULATION...

Page 24: ...24 ENGLISH EVAPORATOR THERMOSTATADJUSTMENT...

Page 25: ...25 ENGLISH TIMER...

Page 26: ...26 WATER SUPPLYAND ELECTRICAL ENGLISH...

Page 27: ...27 ENGLISH ELECTRICAL PANNEL KP 21...

Page 28: ...28 ENGLISH ELECTRICAL PANNEL FROM KP28 TO KP50...

Page 29: ...29 ENGLISH ELECTRICAL PANNEL FROM KP75 TO KP130...

Page 30: ...30 ENGLISH ELECTRICAL PANNEL KP160...

Page 31: ...31 ENGLISH NOTES...

Page 32: ...Via Fusina 1 A 31033 Castelfranco Veneto Treviso Italy Tel 39 0423 724061 Fax 39 0423 743222 E mail info kastelice com KASTELs r l Rev 01 Ed 03 05...

Reviews: