background image

U s e r   m a n u a l   K B -

E C O

L I N E   s e r i e s   E n g l i s h  

 

           
 

                                       

  

   

 
 

Eco

line series

 

          CH 

      Calorifier 

       Combi 

Summary of Contents for ECOLINE KB Series

Page 1: ...User manual KB ECOLINE series English Ecoline series CH Calorifier Combi...

Page 2: ...uctions that can be identified in the following way Hint This gives the user suggestions and advises to facilitate the execution of certain tasks Attention Additional information is supplied to the us...

Page 3: ...nd domestic hot water 8 4 1 3 Flue gas outlet 10 4 1 4 Electrical connection 12 4 1 5 Filling the central heating system 14 4 1 6 Mounting the oil filter and oil burner 15 4 2 Starting your system 15...

Page 4: ...water and for a central heating system The boilers can also be used for the generation of domestic hot water generated by a compact brazed heat exchanger The dimensions of the rooms to be heated have...

Page 5: ...uctions In this chapter we emphasis the safety related points for operating the boiler MEASURES FOR A SAFE INSTALLATION Don t store any flammable and or gaseous products in the room where the boiler i...

Page 6: ...the fuel system While transporting the boiler take following precautions Don t damage the boiler use a blanket to cover the boiler Transport the boiler standing up 3 2 Storage Take the following preca...

Page 7: ...supply of fresh air in the room where the boiler is installed see hint below To avoid movement secure the base of the boiler by using the holes with M5 threat in the feet from the boiler figure 1 Keep...

Page 8: ...iler Attention Install a bleeding point near the boiler especially when the piping does not go up Installation KB CH Connect the piping to the boiler as follows see figure 2 2 2 1 Install the feed of...

Page 9: ...l the return of the boiler and calorifier on nr 2 3 Install the feed of the boiler on 3 A 4 Install the fill and pressure gauge on nr 4 5 The numbers A and B you will find on the housing of the three...

Page 10: ...between 150 200 C it is advisable to insulate the flue with heat resistant material on those parts where contact with human body parts is possible For a correct flue gas outlet the following points n...

Page 11: ...gh waves and under sail For this kind of flue gas outlet the following points are important Install a proper storm cowl on top of the chimney this must stop rain from entering figure 4 Install deck fi...

Page 12: ...er supply from a land line To connect the room thermostat for KB Standard Remove the cover of the thermostat Connect the two thermostat wires to point 2 and 3 figure 6 2 Remove the cover from the conn...

Page 13: ...as shown on the sticker inside the connector Connect the T1 and T2 wires inside the room thermostat Fig 6 1 to 2 and 3 The thermostat itself doesn t have a hot water switch You can use a connect and d...

Page 14: ...to 2 bar of pressure Switch on the boiler and let the pump run for about 5 minutes Switch off the boiler Check the water pressure if it is too low repeat steps 5 through 10 Remove the hose Hint The C...

Page 15: ...n the valve on the fuel tank 5 Open the valve on the oil filter 6 Disconnect the power from the motor to the oil burner only Kabola engineer 7 Use the startup cable and connect with this cable the pow...

Page 16: ...70 C Diesel burner off and the element on 2 3 power 70 C 80 C Diesel burner off and the element on 1 3 power Note The 80 C can be changed by the installer The red colour is showing the active mode in...

Page 17: ...stand by Circulationpump not active 1 Room thermostat is demanding Circulation pump active above 40 C 2 Hot water is being tapped or external boiler requires heat Circulation pump active Oil burner s...

Page 18: ...att 2000Watt or 1000Watt Here is how to set that Be aware of the power consumption from landlines 3000Watt 16Ah 2000Watt 11 Ah 1000Watt 6Ah Push setting Push the green 1 3 button to switch from 3 2 1...

Page 19: ...utton The hot water function can be switch on and off also on the display from the boiler On this display it s called standby First push the button stop Now you can push the functions you want Push st...

Page 20: ...s manual preferably an expert installer or a service engineer from Kabola Heating Systems Every year 1 Clean the boiler 1 1 Remove the burner with the door from the boiler 1 2 Remove the insulation 1...

Page 21: ...Instruction manual Kabola KB Hybrid Series version 1 2022 21 Appendix A Technical specifications...

Page 22: ...ent of flame at the end of safety time Faulty or soiled fuel valves Faulty or soiled flame detector Poor adjustment of burner no fuel Faulty ignition equipment 3x blinks alarm on terminal 10 Free 4 bl...

Page 23: ...Instruction manual Kabola KB Hybrid Series version 1 2022 23 Appendix C Boiler parts...

Page 24: ...Instruction manual Kabola KB Hybrid Series version 1 2022 24...

Page 25: ...Instruction manual Kabola KB Hybrid Series version 1 2022 25 Spareparts list model 2016 2018...

Page 26: ...under our own responsibility that the product Kabola KB20 KB40 KB45 KB50 KB75 combi 230V to which this declaration relates complies with the following standards EN 303 1 EN 303 2 EN 304 EN 50081 1 EN...

Page 27: ...Instruction manual Kabola KB Hybrid Series version 1 2022 27 Appendix E CE declaration...

Page 28: ...Instruction manual Kabola KB Hybrid Series version 1 2022 28 Warranty Conditions...

Page 29: ...Instruction manual Kabola KB Hybrid Series version 1 2022 29 Appendix F Guarantee conditions...

Reviews: