background image

For Customer Use:

Enter below the Model No. and Serial 
No. which are located either on the rear, 
bottom or side of the cabinet. Retain this 
information for future reference.

Model No.

Serial No.

LVT0378-002A

[B]

INSTRUCTIONS

XM-G6

MINIDISC RECORDER

REC

REC  PAUSE

SAMPLING RATE CONVERTER

M I N I D I S C     R E C O R D E R     X M - G 6

XM_cover[B]

99.11.22, 11:08

1

Summary of Contents for XM-G6

Page 1: ...hich are located either on the rear bottom or side of the cabinet Retain this information for future reference Model No Serial No LVT0378 002A B INSTRUCTIONS XM G6 MINIDISC RECORDER REC REC PAUSE SAMPLING RATE CONVERTER M I N I D I S C R E C O R D E R X M G 6 ...

Page 2: ...X UXG6 TD UXG6 XT UXG6R XM G6 AX UXG6 TD UXG6 XT UXG6R XM G6 Caution Proper Ventilation To avoid risk of electric shock and fire and to prevent damage locate the apparatus as follows 1 Front No obstructions and open spacing 2 Sides Top Back No obstructions should be placed in the areas shown by the dimensions below 3 Bottom Place on the level surface Maintain an adequate air path for ventilation b...

Page 3: ...no user serviceable parts inside the Unit leave all servicing to qualified service personnel G 2 DANGER Invisible laser radiation when open and interlock failed or defeated AVOID DIRECT EXPOSURE TO BEAM e ADVARSEL Usynlig laser stråling ved åbning når sikkerhedsafbrydere er ude af funktion Undgå udsæt telse for stråling d VARNING Osynlig laser strålning när denna del är öppnad och spärren är urkop...

Page 4: ...d and then plug it in again DO NOT disassemble the unit since there are no user serviceable parts inside If anything goes wrong unplug the AC power cord and consult your dealer Welcome to XM G6 XM G6 is MiniDisc Recorder exclusively designed for UX G6R micro component system Although you cannot operate this MD recorder without UX G6R this integration offers enhanced features to simple and easy ope...

Page 5: ...gs to Know Before You Start Recording 11 Recording FM AM MW LW Broadcasts 12 Recording a CD 14 Recording a Tape 15 Recording onto a Tape 16 Recording the External Equipment 17 Editing an MD 19 Introducing MD Editing Functions 19 DIVIDE Function 20 JOIN Function 21 MOVE Function 22 ERASE Function 22 ALL ERASE Function 23 Erasing a Portion of a Track 23 Assigning Titles to an MD 24 Assigning a Title...

Page 6: ... on the unit DISPLAY CHARA PLAY MODE REC MODE TITLE EDIT CLOCK TIMER CANCEL ENTER SET 8 9 pqwer ty MOS FET STANDBY ON FM AM AUX OPEN CLOSE VOLUME M I C R O C O M P O N E N T S Y S T E M U X G 6 R 4 AX UXG6 Stereo Amplifier belongs to UX G6R M I C R O C O M P O N E N T S Y S T E M U X G 6 R MOS FET OPEN CLOSE AUX VOLUME MULTI FM AM STANDBY ON JOG 1 4 5 2 3 6 7 When pressing OPEN CLOSE button 4 ...

Page 7: ...button 8 Stereo Amplifier AX UXG6 1 button and STANDBY ON lamp 2 MULTI JOG dial 3 FM AM button 12 4 OPEN CLOSE button 7 5 Display window 6 VOLUME dial 7 AUX button 17 Buttons behind the Sliding Panel 8 DISPLAY CHARA button 13 25 9 4 button 8 9 25 p button 8 9 25 q SET button 9 13 20 25 w CANCEL button 9 21 25 e ENTER button 21 25 r PLAY MODE button 9 t REC MODE button 13 y TITLE EDIT button 20 24 ...

Page 8: ...ut pushing both sides of the connector body Never pull out the cables themselves 4 Using the Optical digital cable connect between XM G6 unit and XT UXG6R unit Now you have finished installation of XM G6 unit to UX G6R system Getting Started Unpacking After unpacking check to be sure that you have the following items Optical digital cable 1 External wire 1 The number in the parentheses indicates t...

Page 9: ...the connection completes DO NOT place an external equipment onto or under UX G6R system and XM G6 unit Damage or malfunction may result from heat generating portion of units 1 Turn off UX G6R system and unplug the AC power cord from the wall outlet 2 Using the Optical digital cable not supplied connect between XT UXG6R unit and another digital equipment Now you have finished installation to UX G6R...

Page 10: ...AY MODE FM MODE CANCEL DISPLAY CHARA BASS SLEEP PANEL OPEN CLOSE REMOTE CONTROL RM SUXG6R TAPE FM AM SET AUX TITTLE EDIT REPEAT TREBLE DIMMER CLOCK TIMER CD ACTIVE BASS EX UP DOWN PLAY MODE REPEAT UP DOWN SET CANCEL MD 6 play pause 4 7 stop REC REC PAUSE SAMPLING RATE CONVERTER MD IN lamp MD loading slot 0 eject 6 play pause 7 stop You can use Normal Program Random or Repeat Play When using the bu...

Page 11: ... Press 0 eject button on the MD recorder to remove the MD Pressing 0 eject button during playback directly the MD recorder stops playback and ejects the MD Searching and Skipping Tracks While playing back an MD you can do the following operations To search and skip to a particular point in a track During playback press and hold 4 button to meet the desired passages in a track Press and hold button...

Page 12: ...ram play mode Before or during playback you can exit from Program play mode as follows Before playback press PLAY MODE button twice During playback press 7 stop button then PLAYMODE button twice Playback mode indicator goes off and the system resumes Normal play mode Pressing 0 0 0 0 0 eject button to eject the MD also quits Program play mode Continued PROGRAM Canceled Normal play RANDOM Programin...

Page 13: ...uffled tracks only Playing at Random Random Play The tracks of the loaded MD will play in no special order at random when you select this mode 1 Insert an MD If the current playing source is not the MD press 6 play pause button on the MD recorder then 7 stop button before going to the next step 2 Press PLAY MODE button repeatedly until MD RANDOM appears in the display window Each time you press th...

Page 14: ...MD To avoid erasing important recordings Recordable MDs have an erasure protect tab so that important recordings are not accidentally erased When you finish recording or editing slide open the erasure protect tab on the cartridge side surface New recording or editing is now no longer possible To do re recording or editing return the tab to the closed position About the track marks When playing an ...

Page 15: ... eject 6 play pause 7 stop REC PAUSE MD loading slot M I C R O C O M P O N E N T S Y S T E M U X G 6 R MOS FET OPEN CLOSE AUX VOLUME MULTI FM AM STANDBY ON JOG OPEN CLOSE FM AM AUX DISPLAY CHARA PLAY MODE REC MODE TITLE EDIT CLOCK TIMER CANCEL ENTER SET SET REC MODE 4 Continued XM G6 allows you to record a variety of audio sources onto an MD using either manual recording or synchronized recording ...

Page 16: ...u can record FM AM broadcasts for twice as long as given recording time of the MD in monaural reception 1 Repeat the steps 1 2 and 3 in previous page 2 Press REC MODE button to select a recording mode as follows 3 Press SET button to start recording You can double the recording time length and information appears in the display window as follows Remaining time for recording To stop recording tempo...

Page 17: ...t track is recorded both CD player and MD recorder automatically stop Recording a CD When recording a CD onto an MD you can record the entire CD or the particular tracks manually and using the synchronized recording Recording a CD Manually You can start recording an entire CD or any tracks of a CD while listening 1 Insert a recordable MD into the MD loading slot The MD IN lamp lights orange 2 Prep...

Page 18: ...d Synchronized Recording Manual Recording Sound is recorded in stereo both on the left and right audio channels You have to operate the MD recorder and the cassette deck respectively Sound Synchronized Recording With this method you can start recording when the sound signals come into the MD recorder sound is recorded in stereo Sound Synchronized Recording will stop automatically if no sound comes...

Page 19: ...EC PAUSE button on TD UXG6 cassette deck to prepare for recording 4 Press 6 play pause button on the MD recorder or MD 6 play pause button on the remote control The cassette deck automatically starts recording and the information changes as follows Track number Elapsed playback time 5 Press 7 stop button on either the MD recorder or the cassette deck to quit recording as required When all the trac...

Page 20: ...manual and refer to UX G6R s Instructions pages 9 1 Insert a recordable MD The MD IN lamp lights orange 2 Press AUX button to select either analog source or digital source according to the external equipment Each time you press AUX button AUX mode changes between AUX and AUX DIGITAL alternately 3 Press REC PAUSE button on the MD recorder The REC indicator on the MD recorder lights red and the MD r...

Page 21: ... Press REC MODE button to select recording mode as follows 4 Press SET button to start recording from the external equipment Selected source and remaining time for recording appear in the display window as follows or To stop recording temporarily press REC PAUSE button or 6 play pause button on the MD recorder or MD 6 play pause button on the remote control To resume recording press 6 play pause b...

Page 22: ...art of an existing track You can also assign titles to MDs and or tracks See page 24 You can also assign titles to MDs and tracks see page 24 A title can be assigned to a track or disc Once a title is assigned it is displayed in later playback for confirmation Each title can be composed of up to 64 characters digits and can be input using alphabetic characters uppercase and lowercase symbols and n...

Page 23: ... to open the sliding panel first To operate with the remote control press MD 6 play pause button first and 7 stop button successively To quit operations any time during editing process press TITLE EDIT button repeatedly to resume normal operation mode DIVIDE Function This function allows you to divide one track into two separate tracks It is useful for example when you want to add track marks at a...

Page 24: ...ton to eject the MD WRITING appears while the editing you have made is being recorded onto the MD To join the divided tracks again see the JOIN function JOIN Function This function allows you to join two adjacent tracks into one track To quit any time during editing process press TITLE EDIT button 1 Insert an MD you want to edit into the MD loading slot The MD IN lamp lights orange 2 Press TITLE E...

Page 25: ...ton also available If you want to cancel the editing press TITLE EDIT button 8 Press ENTER button to finish the editing procedures 9 Press 0 eject button to eject the MD WRITING appears while the editing you have made is being recorded on the MD ERASE Function This function allows you to erase an unwanted track To stop any time during editing process press TITLE EDIT button 1 Insert an MD you want...

Page 26: ...en write protected by another component You cannot edit such a protected track To cancel the editing press TITLE EDIT button 4 Press ENTER button to erase all the tracks 5 Press 0 eject button to eject the MD WRITING appears while the editing you have made is being recorded on the MD Erasing a Portion of a Track You can erase just a portion of one track by using the DIVIDE ERASE and JOIN functions...

Page 27: ...t to edit into the MD loading slot The MD IN lamp lights orange 2 Press TITLE EDIT button to enter title entry mode as follows a Pressing once makes track title entry available b Pressing twice makes disc title entry available and go to step 4 Assigning Titles to an MD VOLUME MD ENTER PTY EON AUTOPRESET PLAY MODE FM MODE CANCEL DISPLAY CHARA BASS SLEEP PANEL OPEN CLOSE REMOTE CONTROL RM SUXG6R TAP...

Page 28: ...er scrolls out to the left end You can also scroll back to select and insert a new character using MULTI JOG dial and the similar controlling buttons If you have entered an incorrect character press CANCEL button to delete the last entry To enter a blank select a blank in the upper portion in the display window then press SET button 7 Repeat steps 5 and 6 to enter and edit other characters 8 Press...

Page 29: ... sure that the character you want to change is blinking 3 Press CANCEL button to delete the character you have selected in the step 2 4 Enter the correct character a Press DISPLAY CHARA button to select the character set you want b Rotate MULTI JOG dial or press button to select the correct character then press SET button 5 Repeat steps 2 to 4 to correct another characters 6 Press ENTER button twi...

Page 30: ... place subject to direct sunlight or where the temperature rises for example in a closed automobile The disc may be warped and unusable in these places In a bathroom or where the humidity is high The disc may be rusted in these places On a beach or sandbox The disc surface may be scratched or damaged if grit penetrates through an opening on the cartridge Periodical maintenance When the cartridge g...

Page 31: ... MD demagnetizing the magnetic layer of the MD for recording and playback This type of MD is called magnetic optical disc ATRAC Adaptive TRansform Acoustic Coding The MD provides 80 max minutes recording and playback time more than that of an audio CD but in a diameter of only 64 mm This ability to store such a large amount of data is the result of ATRAC an audio compression technique developed fo...

Page 32: ...eproduced as audio signals Thus even when vibration or shock interrupts signals being read these stored signals can continue to reproduce sounds for the few seconds Thus the user will enjoy uninterrupted music DIGITAL ABCDEFG DIGITAL OK NO Serial Copy Management System SCMS The MD recorder integrated to this unit uses the Serial Copy Management System which allows only first generation digital cop...

Page 33: ...g to copy a non audio disc like a CD ROM or a Video CD You are trying to edit or record on a playback only MD Digital copy of the 2nd generation is prohibited A track has been protected against accidental erasure by other component than the MD recorder in use Solution Change the MD with another if you want to enjoy playback This is not a malfunction see MD Restrictions on page 31 Connect digital d...

Page 34: ...There is a maximum number of tracks which can be recorded regardless of recording time More than 254 tracks cannot be recorded on an MD Repeating erasure and recording on the same MD creates many blank portions sparsely on the MD When recording on such an MD a track is recorded on these blank portions sparsely If a track is divided and recorded into so many portions DISC FULL appears If a divided ...

Page 35: ...terference Action Check all connections and make corrections see pages 5 6 Change it with a recordable MD Unprotect the MD see page 11 Remove the obstruction Replace the batteries Plug in the AC power plug Unplug the unit then plug it back in Specifications MD recorder Audio Playing System MiniDisc digital audio system Recording System Magneto optical overwrite system Reading System Non contact se...

Page 36: ...J VC 1299JTMMDWJSC EN VICTOR COMPANY OF JAPAN LIMITED ...

Reviews: