manualshive.com logo in svg
background image

COMPLEX RADIO CONTROL SYSTEM

User Manual

User Manual

EN

Receivers Rx 

Receivers Rx 

®

COMPLEX RADIO CONTROL SYSTEM

Содержание duplex

Страница 1: ...COMPLEX RADIO CONTROL SYSTEM User Manual User Manual User Manual EN Receivers Rx Receivers Rx Receivers Rx COMPLEX RADIO CONTROL SYSTEM...

Страница 2: ...ta 05 2 1 TechnicaldataofreceiversoutsidetheUS 05 2 2 TechnicaldataofreceiversfortheUS 07 3 Installation 09 3 1 Voltage Supply 09 3 2 Operation 09 3 3 Binding 10 3 4 ReceiverR7nano 11 4 RealTimeTeleme...

Страница 3: ...ceiver 14 5 1 2 Wireless connection between a JETIBOX with transmitterorDC DStransmitterandthereceiver 14 5 2 Receiverset upviatheDC DStransmitter 15 6 Receiver Menu 16 6 1 Overview of receiver data i...

Страница 4: ...Duplex receivers are offered in a wide range of size and features to suit the numerous demands of our customers The Duplex receivers range from the tiny Duplex R3L R5L receivers for small and medium m...

Страница 5: ...compatibility with a large number of telemetry sensors from both JETI model and third party producers For the display of telemetry data you can use purposely designed equipmentliketheJETIBOXprofiand D...

Страница 6: ...0 2x100 1x30 2x200 No of channel outputs 4 5 7 9 Temperature range C 10 up to 85 10 up to 85 10 up to 85 10 up to 85 Supply voltage V 3 5 8 4 3 5 8 4 3 5 8 4 3 5 8 4 Average current mA 75 30 20 30 Rea...

Страница 7: ...gth mm 2x400 2x400 2x200 No of channel outputs 14 18 Serial communication Temperature range C 10 up to 85 10 up to 85 10 up to 85 Supply voltage V 3 5 8 4 3 5 8 4 3 5 8 4 Average current mA 40 40 30 R...

Страница 8: ...perature range C 10 up to 85 10 up to 85 10 up to 85 10 up to 85 10 up to 85 Supply voltage V 3 5 8 4 3 5 8 4 3 5 8 4 3 5 8 4 3 5 8 4 Average current mA 30 30 30 30 30 Real time transmission of teleme...

Страница 9: ...up to 85 10 up to 85 10 up to 85 Supply voltage V 3 5 8 4 3 5 8 4 3 5 8 4 3 5 8 4 Average current mA 30 30 40 40 Real time transmission of telemetry data Yes Yes Yes Yes Programming JetiBox DC DS Jet...

Страница 10: ...tlechannel whenapplyingspeedcontrollerswithBEC afreereceiveroutput a Y cable to any arbitrary receiver output other than the Ext the MPX connector for receivers with the EPC label or the R14 and R18 r...

Страница 11: ...0 seconds After the 60 seconds elapse the receiver returns to setup mode and the binding process must be repeated by starting again fromstep1 3 Switch on the transmitter the transmitter emits an acous...

Страница 12: ...r BIND PLUG is removed the receiver returns to your selected setupmode EN 11 3 4ReceiverR7nano When soldering it is necessary to have the receiver disconnected from the power The receiver is a very se...

Страница 13: ...o the plus Solder the yellow white or orange wire tothesignal SERVO 2 1 5 6 R R 7nano 7nano R7nano 4 3 7 E x t 7 CHANNEL RECEIVER impuls plus minus SERVO JETIBOX Sensor Expander ELECTROSTATIC SENSITIV...

Страница 14: ...ftheJETIDC DStransmittersortheJETIBOX profi The 1stGenerationTelemetry can be used by owners of the TU TG TFetc transmittermodules 4 1EXTelemetry This telemetry data is displayed according to user sel...

Страница 15: ...er seeVoltage supply or to the supply socket of the JETIBOX There is no need to supply voltage when usingtheJETIBOXprofi 5 1 2WirelessconnectionbetweenaJETIBOXwith transmitterorDC DStransmitterandther...

Страница 16: ...ourse toyoursetupwork Ifitispossible wedonot recommend changing setup parameters during model operation Set up work should only be done if there is no danger of damaging the model or injuring people F...

Страница 17: ...item shows the unique production number of the receiver The TX item shows the unique production number of the transmitter towhichthereceiverhaseventuallybeenpaired RxDiag A1orA2itemshowswhichantennath...

Страница 18: ...function is disabled there are no signals generated on receiver outputs in case of signal loss If the Fail Safe function is activated the receiver outputs are generated according to your individual c...

Страница 19: ...ers standard servo signals are generated by the receiver outputs JETIBOX output availableonExt port JETIBOX PPM pos setup of the standard form of PPM signal generation with positive logic at PPM outpu...

Страница 20: ...If the receiver receives less channels than selected in setup the remaining channels will be replacedby a throw specified by the Fail Safe value for individual channels Otherwise the numberofoutputpul...

Страница 21: ...ceivers in Normal mode and the others in clone mode the receiver operating in Normal mode is considered to be the main receiver One of the transmitter modules is able to control onlyonereceiverin Norm...

Страница 22: ...sible because the receiver is now communicating only unidirectionally In order to change the mode or setup you have to connect the JETIBOX to the receiver and make the desired change or switch the rec...

Страница 23: ...error code in case one of the SAT1 2 outputs is set to PPM input mode an acoustic signal can be set up to announce that this connected signal is missing By loading a character from the Morse alphabet...

Страница 24: ...tion log 1 ensure that pin is used only as logical output don t draw the currentabove1mA PinConfig Digitalinput here the pin is configured as an input and its condition disconnected connected to the g...

Страница 25: ...LEX RADIO CONTROL SYSTEM 24 R4 RES R5L R9 R14 R18 R sat2 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 Y10 Y11 Y12 Y13 Y14 Y15 Y16 Y17 Y18 SAT1 SAT2 PPM Assignment table of receiver outputs servo PPM output UDI PPM inpu...

Страница 26: ...OL SYSTEM 25 Assignmenttableof USversionreceiveroutputs R3 R4L R4Li R5L R5Li R6L R6Li R7 plus R9 R11 EPC R14 R18 Y1 Y2 Y3 Y4 Y5 Y6 Y7 Y8 Y9 Y10 Y11 Y12 Y13 Y14 Y15 Y16 Y17 Y18 SAT1 SAT2 PPM input PPM...

Страница 27: ...telemetry are strictly limitedaccordingtotheneedsoftheEREScompetition Sensorsettings Motorshutdownpulse default1 100ms Switch offheightsetting 90mbydefault Switch offtimesetting 30sbydefault The speed...

Страница 28: ...e seen if the receiver is in the Ready or Done status The receiver save the data from the last measurement and can be read again after connecting the power supply In the ready status you can view the...

Страница 29: ...etlevel The motor will be stopped whichever occurs first terms above After stopping the motor the motor cannot be restarted until the receiver power is disconnected and connected again and the receive...

Страница 30: ...th the transmitteriskept Duplex Rx receivers can be upgraded by a PC and a JETI USB adapter You can find a detailed description of the update procedure on our website in the technical support section...

Страница 31: ...rantawarrantyof 24monthsfromthedayof purchase under the assumption that they have been operated in conformity with these instructions at recommended voltages and that they were not damaged mechanicall...

Страница 32: ...COMPLEX RADIO CONTROL SYSTEM EN 31...

Страница 33: ...crystals safe operation real time telemetric data transfer two receiver antennas response of receiver exits without time delay simultaneous operation of several receivers with oneTx module acoustical...

Отзывы: