Safety & Operating Instructions for PROGRES GRYPHAX Microscope Cameras    

 

 

 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Type Label 

 

Note:

 Please observe the information on the type label when installing the camera. 

The following information is printed on the type label: 

(e.g. PROGRES GRYPHAX SUBRA)

 

 

1. 

Camera type: 

 

2. 

Serial number (written and in QR-code format): 

 

3. 

Manufacturer’s website: 

 

4. 

CE mark / WEEE mark / Voltage / Power: 

 

5. 

Country of origin: 

 

Service & Support 

 

In the first instance, please have a look into our video tutorials and our FAQs to find a solution to your issue: 

http://www.jenoptik.com/en-progres-gryphax-software

 

 

Should you need further support please contact your local dealer for questions regarding PROGRES GRYPHAX cameras. 
Your local dealer can provide you with detailed information about the product, accessories, and applications in 
microscopy.  

 

If a solution cannot be found, please contact Jenoptik’s technical support team at:

 [email protected] 

 

If you need to return your camera for repair, 
please send it to the following address:   

JENOPTIK Optical Systems GmbH 
Attn. Steffen Derbsch / HC Service & Repair Centre 
Pruessingstrasse 41 
D-07745 Jena, Germany 

Dear PROGRES GRYPHAX user, 
 
Welcome to the PROGRES GRYPHAX community! Please read the safety & operating instructions carefully before 
using your PROGRES GRYPHAX camera. By observing the advice on this page, you can make optimum use of the 
functions and avoid causing damage or injuries resulting from operating errors. The safety & operating instructions  
apply for all PROGRES GRYPHAX cameras in connection with PROGRES GRYPHAX imaging software. 

 
 

Intended Use 

 

PROGRES GRYPHAX cameras are intended for the use on a microscope.  
They can be adapted via c-mount adaption to the microscope and via USB3.0-cable to a computer or laptop. 

 

 

Power Supply 

 

For PROGRES GRYPHAX cameras, power supply and data communication are carried out using the USB3.0 cable.  
Additional power supply connections are not necessary. 
 

Technical Drawing / Dimensions 

 

 

Instructions for Use 

 

Our video tutorials contain all necessary information for the installation and operation of PROGRES GRYPHAX cameras. 
They help you to capture and process your microscope images in the easiest way. You will find these video tutorials at 

www.jenoptik.com/progres-gryphax

 as well as on the USB memory card included with your camera. 

 

Contents 

 

1. 

PROGRES GRYPHAX microscope camera 

2. 

PROGRES GRYPHAX software - available:   

• on USB-memory card – item 5,  

 

• to download at 

www.jenoptik.com/progres-gryphax

 

 

• on request by e-mail at [email protected] 

3. 

Safety and Operating Instructions & Quick Start Guide 

4. 

USB3.0 cable 

5. 

USB memory card containing user video tutorials & PROGRES GRYPHAX software 

6. 

Microfiber cleaning cloth in a zip-lock bag 

Disposal 

 

 

 

Manufacturer Information    

 

 

 
 
 

 

Editorial Information 

 

Editorial deadline:    

 

 

February 2016 

Documentation number:  

 

 

014102-202-98-01-en-004-213-1501 

Revision status: 

 

 

 

Revision 04, Release 001 

 

Important note:

 This instruction manual or parts of this manual must not be reproduced in any form (either print, 

photocopy, microfilm, or otherwise) without prior written permission from Jenoptik, nor must its contents be used, 
reproduced, processed, or distributed electronically. 
These safety & operating instructions were produced with due care. No liability will be accepted for damages 
resulting from non-compliance with the advice contained herein. 
We reserve the right to make improvements and changes to the device and to this instruction manual at any time 
without prior notice. 
 

System Requirements 

 

Operating System 

For Windows PC: OS Microsoft Windows 7 / 8.1 / 10 – or higher 
For Apple Macintosh: OS X 10.8 - or higher 
For LINUX: OS Ubuntu 14.04 LTS 

 

Hardware 

Minimum:  

 

 

 

 

Recommended: 

• USB3.0 - PCI Express from V1.1,  

 

 

• USB3.0 - PCI Express V2.0   

• Processor: i5 Dual core (or comparable), 4 GB RAM  

• Processor: i7 Quad core (min. 3 GHz), 8 GB RAM 

• Monitor resolution 1280x720  

 

 

• Monitor resolution: 1920x1080 

for all GRYPHAX cameras 

• Graphic card equipped with on-board memory 

 

 

 

 

 

 

 

• Graphic card equipped with on-board memory

 

 
Recommended PCI Boards 

For PC: 

PCI Express Card, item # Jenoptik order number: 567069;  
Technical requirement: PCI Express 2.0 (Important: never use PCI Express 1.0!!!) 
Driver requirement for Windows 7: USB 3.0 host controller driver (32 & 64 Bit) - Freeware

 

http://www.station-drivers.com/index.php/downloads/Drivers/Renesas-Nec 

For Windows 8.1: no drivers are needed; support is already built into the OS. Just plug in and reboot. 

 

For Notebooks:  

Express Card, item Jenoptik order number: #576563; 

 

 

Disclaimer 

 

Exemption from warranty: 

Jenoptik shall be exempt from warranty during the warranty period in the event 

that the safety regulations are not observed. 

 

 

 

Safety & Operating Instructions 

 

PROGRES GRYPHAX cameras are intended for the use on a microscope and for operation and control with 
PROGRES GRYPHAX microscopic imaging software. The PROGRES GRYPHAX microscope camera is an optical and 
fine mechanical device. Please handle it with due care.  

 

 

 

 

 

 

 

 

 
 

 

 
 
 
 
 
 
 
 

 

 
 
 

 

 
 

 
 
 
 

 

 
 
 

 

 
 

 

 

 
 
 
 

 

 

 
 

 

 

 

 

 

 
 

 
 

 

 

 

 
 

Operating temperature:

  

 

 

+10 °C ... +35 °C 

 

Relative humidity:

   

 

 

  5 % ... 80 %, non-condensing 

 

Storage and transportation temperature:

  

-20 °C ... +70 °C 

 

Advice for transportation and storage: 

Protect the camera against impact. Store and transport the camera in 

a dry and cool place, e.g., in its case or the packaging in which it was delivered. Please use the supplied C-mount 
cover during transportation and storage. 

Conformity to CE / WEEE / ROHS 

 

PROGRES GRYPHAX microscope cameras comply with: 
• CE in accordance with EMC Directive 2014/30/EU   

 

• WEEE 
• ROHS 

Cleaning and Maintenance 

 

Cleaning the camera casing

: If the camera casing is only slightly soiled, clean it with a soft, slightly moistened piece 

of cloth e.g., the microfiber cleaning cloth included with your camera. Make sure that no water enters the camera and 
risks becoming in contact with any internal components. Do not use any aggressive substances or solvents to clean 
your camera. 

 

Cleaning the filter glass: 

Cleaning the filter glass by yourself is not recommended. If the filter glass is severely soiled, 

please contact your expert dealer or the manufacturer for assistance. 
 

Trigger Operation 

 

Some PROGRES GRYPHAX cameras support trigger operation (connection to an external trigger device, which delivers 
the signal (Trigger In) to the camera and which will react, e.g. by capturing an image. After image capture, the camera 
delivers a signal to the device (Trigger Out) to signal the completion of the function. Trigger Out does not require any 
additional power supply; for Trigger In, power supply must be set up for the external device. Connect the cable shield 
with the casing of the external device. Only use shielded cables. 

 

The sign 

Caution

 warns against possible health dangers at risk if the advice is not observed. 

 

The sign 

Attention

 warns against possible damage to the instrument. 

 

The sign 

Information

 highlights important information for the operation of your camera. 

 

This symbol highlights that special guidelines have to be followed when disposing of this product. 

Every PROGRES GRYPHAX camera has been thoroughly tested and has left the factory in perfect operating 
condition. 

 
 

For your own safety and to keep the camera in good operating condition, please follow all safety and 
operating instructions in this document and observe all advice and labels on the unit and on any accessory. 

Exemption from statutory liability for accidents: 

Jenoptik shall be released from statutory liability for 

accidents that occur in the event of non-observance of the safety instructions by any operating person.

 

Expansions and alterations: 

The camera must be operated in compliance with these safety instructions. 

Do not attempt to carry out any expansions, adjustments, alterations, or repairs by yourself. Repairs and 
maintenance work may be carried out only by authorized service personnel.

 

Electric installations: 

The electric installations of the room where the system is set up must be in 

compliance with the IEC requirements.  

Voltage supply: 

5 V

 (USB) / Consumption: Variable according to camera type. Please refer to your 

camera’s technical data sheet. 
Unplug the USB cable to disconnect the camera from the power supply. 
Use only cables included with your camera or explicitly recommended by Jenoptik. 
• 

Make sure that the cables are installed so that they do not obstruct persons and do not cause a tripping risk. 

• Protect cables against mechanical impact or damage. 

Note: 

Observe the information on the type label when installing the camera. 

Caution, fire hazard! 

To prevent a risk of fire, do not operate or store the camera nearby easily 

inflammable materials or gases. 

 

Caution, risk of injury! 

Operating the camera under the following circumstances risks injury: 

• The camera is visibly damaged 
• The camera has been stored under adverse conditions over a long period of time 
• The camera has been transported under adverse conditions 
If any of these circumstances apply, switch off the camera and ensure that it cannot be operated 
unintentionally. Please contact your expert dealer or the manufacturer’s technical support team for 
assistance.

 

 

Caution, risk of damage by unsuitable environment conditions! 

Do not expose the camera to 

extreme environment conditions. Avoid extremely high or low temperatures, and keep the camera away 
from high humidity, liquids, chemical gases, dust or high electro-magnetic fields.

 

Caution, risk of injury or damage by water! 

If water (or other liquids) enters the camera, there is a risk 

of electric shock. Your camera can also be damaged or no longer usable. If water has entered the camera, 
switch it off and contact your expert dealer or the manufacturer for assistance.

 

Caution, risk of damage by static charge! 

Static charge can damage or destroy the electronic 

components of your camera. Before connecting the camera to a computer or a microscope, make sure 
that it is free of electrostatic charge. Ground yourself by touching the metallic housing or the reverse side 
of your computer or microscope, which both have to be grounded via a power socket.

 

Caution, risk of malfunction by insufficient ventilation! 

Some PROGRES GRYPHAX cameras are 

equipped with louvers on the rear side. Ensure that the cameras are sufficiently ventilated and that the 
louvers are not covered. 

 

Caution, risk of damage and malfunction by overheating! 

Avoid leaving your camera in direct sunlight 

and do not operate the camera near heat sources (e.g., radiators or stoves). Overheating can affect the 
image quality. 

 

Advice for handling the IR filter glass: 

Protect the integrated IR filter glass against mechanic impact such 

as scratching or shock and against soiling. Avoid fingerprints on the glass and do not touch the C-mount 
cover of the camera. 

 

Caution, risk of damage and image errors by mechanic impact! 

Protect the camera against impact, 

especially during operation. Mechanic impact can affect image quality. 

The camera must be disposed of in compliance with the environmental protection guidelines in force. 
Contact your expert dealer in case of any questions. 

 

JENOPTIK Optical Systems GmbH  
Business Unit Healthcare 
Goeschwitzer Str. 25 
07745 Jena, 
Germany 

 

Phone.:   +49364165-2143 

 

E-mail:   [email protected] 
Website:  

www.jenoptik.com/progres-gryphax

 

Take care to use only the USB3.0 cables included with your camera or explicitly recommended by Jenoptik.

 

PROGRES GRYPHAX cameras should be used in clean and dry locations.

 

3840x2160 

for ARKTUR and NAOS

 